Connection Terminal
AR-2802 and AR-2807 AR-2806
10987654321
LED
DATA
I/O
TAMPER
N.C.
( + ) ( – )
12-24V DC
WIEGAND
D0 D1
BUZ
RS
232
Version "A" ONLY
654321
LED
DATA
I/O
TAMPER
N.C.
( + ) ( – )
12-24V DC
10987
WIEGAND
D0 D1
BUZ
RS
232
Version "A" ONLY
41. AUXILIARY INFORMATION
DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connections. The Relay Output
contacts provided in this keypad system are dry contacts.
N.C.
Normally Closed, the contact is closed circuit at normal status. It is open circuit when active.
N.O.
Normally Open, the contact is open circuit at normal status. It is closed circuit when active.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground similar to a relay
contact referring to ground. The transistor is normally OFF, and its output switches to ground (-) when active. The
open collector can only provide switching function for small power but it is usually good enough for controlling of
an alarm system. The Duress, Inter-lock and Key Active/Alarm Outputs of the keypad are open collector outputs.
OPEN COLLECTOR
OUTPUT ----
Output switches to
ground when activated
EQUIVALENT
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated