Pay attention to the information in chapter "Preparations for Installation"!
Remove the mounting plate on the rear of the wall lamp by unfastening the four
headless screws to the left and right. Use the Allen key provided.
If plugs are needed for securing the mounting plate (depending on the texture of the
wall), mark the position of the drill holes through the holes in the mounting plate.
The mounting plate needs to be mounted to the wall horizontally.
When drilling mounting holes or screwing into place, ensure that no existing
cables or pipes are damaged.
Push the mains cable through the appropriate cable bushing in the mounting plate
and attach the mounting plate to the wall using suitable screws (and wall plugs, if
necessary).
Connect the mains cable using the terminal strip in the wall light's housing (brown
cable = L, blue cable = N, green/yellow cable = PE/earth, earth symbol).
The protective earth wire must be connected!
If the wall lamp replaces an existing lamp and there is not a protective earth
wire available, the lamp must not be installed. First, draw a new mains cable.
In the case where no protective earth conductor is connected, faulty function-
ing of the mains voltage might charge the metal housing of the wall lamp.
There is a risk of a life-threatening electric shock!
Make sure only the minimum required length of the cable is stripped; otherwise it
could cause a short-circuit.
Also check the other screwing connections at the terminal strip (for the connection
cables of the wall light) and fasten them, if necessary.
Place the wall lamp on the mounting plate. Make sure that the mains cables are not
pinched and that the sealing is placed correctly on the mounting plate.
Fasten the wall light on the mounting plate by bolting down the four headless
screws to the left and right.
Install two suitable light bulbs; see the following section, "Installing/changing light
bulbs."
After inserting the bulbs, switch on the mains voltage again and make sure that the
wall light is functioning.
If the bulbs in the wall light do not light up, switch off the mains voltage im-
mediately (take out fuse or switch off at the circuit breaker, switch off the FI
protective switch).
Thereafter, check the connections of the wall lamp.
In case of doubt, contact a professional (e.g. an electrician)!
Inserting/Replacing the Bulb
Attention, risk of burns!
Before you replace a faulty bulb, switch off the lamp and wait until the faulty
bulb and the lamp have cooled down suf ciently.
Caution!
Don't insert or change a bulb when it is raining, but only when the weather
is dry.
Switch off the mains voltage to the wall lamp at all costs, unless it is already discon-
nected.
Turn the light head (the transparent diffuser) counter-clockwise, to the left, and re-
move it.
To remove the faulty bulb, just turn it slightly counter-clockwise, to the left; it can
then be removed from the lamp socket.
Insert a new GX53 energy-saving light bulb (max. 11W) and lock it in place, by a clock-
wise turn to the right.
The operation of the wall lamp is only allowed, when a light bulb is installed
in both sockets.
Replace the light head and tighten it by turning it clockwise, to the right. Ensure the
correct t of the sealing ring.
After installing or changing the bulb/bulbs, switch on the power for the wall light
again and check the function.
Maintenance and Care
The wall light is maintenance-free, except for the occasional replacement of the light
bulb. Repair or maintenance work must be carried out by a specialist.
Switch off the wall lamp or disconnect it from the mains before cleaning. After that,
allow suf cient time for the wall light to cool down.
The exterior of the wall lamp should only be wiped with a clean, soft, dry cloth. Do
not use aggressive cleaning agents or chemical solutions that could damage the
housing (discolouring) or impair operation.
Do not press too hard on the housing or the glass covers, as scratches might appear.
Disposal
Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
Technical Data
Operating voltage: 220 - 240 V/AC, 50 Hz
Type of light source: 2x Socket GX53, each max. 11 W
Protection class: I
Protection class: IP54
Installation location: Indoors and outdoors
Dimensions (H x W x D): Approx. 125 x 90 x 106 mm
Weight: Approx. 815 g
These operating instructions are a publication by Sygonix GmbH, Nordring 98a, 90409 Nürnberg (www.sygonix.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, micro lming, or the capture
in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is
prohibited. These operating instructions represent the technical status at the time of printing. Changes in techno-
logy and equipment reserved. © Copyright 2013 by Sygonix GmbH.
Nr. 33097D- Version 01/13Legal notice