User manual

48
MenuINSTALL SETTINGS”
Function H1HEAT OR COOL”
Switching between heating and cooling operation (depending
on the desired operating mode or the connected consumer
(heating or cooling device)
Function H2VALVE PROTECT”
Scale protection for heater valve on/off
Function H3FROST PROTECT
Frost protection on/off
Function H4OPTIMUM START”
The connected consumer may be activated earlier to reach the
desired temperature more quickly
Function H5RESET ALL”
Resetting to universal thermostat to factory settings