User manual

10
CONNECTION TERMINALS
NOTE:
DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connections.
N.C.
Normally Closed, the contact is closed circuit at normal state. It is open circuit when active.
N.O.
Normally Open, the contact is open circuit at normal state. It is closed circuit when active.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground similar to a relay
contact referring to ground. The transistor is normally OFF, and its output switches to ground (
-
) when active. The
open collector can only provide switching function for small power but it is usually good enough for controlling of
an alarm system. The maximum rating is 24V DC/100mA Sink
OPEN COLLECTOR
OUTPUT ----
Output switches to
ground when activated
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated
EQUIVALENT
STATUS LED FLASHING ON-OFF DURING STANDBY (Location 73)
STANDBY FLASHING ON-OFF
Some people find the flashing light of the status LED (the amber LED) is annoying during the keypad is on standby,
especially at the night time. The standby flashing can be ON-OFF with the setting here.
1
--- Standby Flashing ON -- (Default)
The Status LED gives Standby Flashing all the time during the keypad is on standby. It also gives all the light
indications showing the operation status of the system.
0
--- Standby Flashing OFF
The Standby Flashing is disabled but it does not affect the system status indications. All the light indications from it
are unchanged.
DOOR FORCED OPEN WARNING & TIMING (Location 80)
DOOR FORCED OPEN WARNING ON-OFF & TIMING
The Door Forced Open Warning function requires a Door Position Sensing switch (usually a magnetic contact) to work
with. Once a Timing Figure is put into the Function Mode box, the warning mode is enabled.
0
--- Door Forced Open Warning OFF – (Default)
1
-
999
--- Door Forced Open Warning & Alarm ON & Timing
The Timing Figure for the Warning can be 1-999 seconds. The keypad generates the door forced open warning
beeps and activates the alarm output (Terminal 13) instantly if the door is forced to open without a valid User PIN/
Card or pressing of the Egress Button. The beeps and alarm will last as long as the time set on the timer and it can
be stopped at anytime with an User PIN/Card in Group 1 before the end of the time.
The Manner of The Door Forced Open Warning:
a) The door is forced to open (without using PIN/Card or Egress Button) – Warning & Alarm
b) The door is opened with PIN/Card – No Warning or Alarm
c) The door is opened with Egress Button – No Warning or Alarm
DOOR PROPPED-UP WARNING & THE DELAY TIME (Location 81)
DOOR PROPPED-UP WARNING ON-OFF & TIMING
If somebody opened the door and it is left open longer than the allowable delay time, the keypad will generate door
propped-up warning until the door is re-closed. There is warning beeps from the keypad only but does not activates
the alarm output.
0
--- Door Propped-up Warning OFF – (Default)
1
-
999
--- Door Propped-up Warning ON & The Delay Time
The Delay Time can be 1 to 999 seconds. It is the time allows the door to open without starting of the warning.
FUNCTION MODES
FUNCTION MODES
VALIDATION
VALIDATION
LOCATION
LOCATION
0
or
1
-
999
0
or
1
-
999
#
#
80
81
FUNCTION MODES VALIDATIONLOCATION
1
or
0 #73
35
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
OPEN COLLECTOR OUTPUT
OPEN COLLECTOR OUTPUT
1A RELAY DRY CONTACTS
FOR AUXILIARY CONTROL
1A RELAY DRY CONTACTS
FOR AUXILIARY CONTROL
5A RELAY DRY CONTACTS
FOR DOOR STRIKE
OPEN COLLECTOR OUTPUT
OPEN COLLECTOR OUTPUT
INPUT/OUTPUT FOR SPLIT-DECODED SIGNALS
POWER OUTPUT FOR KEYPADS
COMMON GROUND
POWER INPUT FOR SYSTEM
N.C. SW
COMMON GROUND
N.C. SW
N.O. SW
N.O. SW
N.O. SW
OUTPUT 1O UTPUT 2O UTPUT 3
MASTER
MASTER
INDIVIDUAL