User manual

16
APPLICATION EXAMPLES
1) BASIC WIRINGS OF A SPLIT-DECODED DOOR LOCK
NOTE:
• Connect the 1N4004 as close as possible to the lock in parallel with the lock power terminals of the lock to absorb
the back EMF to prevent it from damaging the keypad. The 1N4004 is not required if the electric lock is AC operated.
• To avoid Electro-Static-Discharge from interfering with the operation of the keypad, always ground the (
-
) terminal
of the keypad to earth.
• Always connect DOOR SENSOR terminal to (
-
) ground if not used.
• Always connect TAMPER terminal to (
-
) ground if not used.
• Make 3-wire Connection (+,
-
, DATA I/O) to the keypad in the DK-2800 series. More than one keypads can be
connected in parallel.
4) Example 4 -- EM Card + Common User PIN :
i) Programming :
10
4
003
#
(a) (b) (c) (d) (e)
(a) The card is programmed for operating of the Output 1
(b) The operation is “EM Card + Common User PIN”
(c) Take ID number 003 in Group 1 to store the card, which is one of the IDs in 000-999
(d) Put the card close to the reader. One beep confirms the reading. (No need to key in a Common User PIN but
there MUST be a Common User PIN already recorded in Location 03; (or 04, 05 if for O/P 2, O/P 3).
(e) Press # to store the “Card” into memory. Two-beep confirms a valid entry
ii) Operation : (while the system is back to operation mode)
#
(a) (b) (c)
a) Put the EM card close to the reader. One-beep confirms the reading and 30 seconds waiting time is given for the
entry of the Common User PIN, the Amber LED keeps flashing
b) Key in the Common User PIN “1 3 5 7” (the number programmed in “Location 0 3” for Output 1 in the previous
Example)
c) Confirm it with the # key. Output 1 activates
5) Example 5 -- Delete an User PIN & / or EM Card (for O/P 1, 2 or 3) :
i) Delete An User PIN or A Lost EM Card
10
5 #
(a) (b) (c) (d)
a) Key in the User Group that the User ID belongs to. “10” for the Group 1, “20” for the Group 2, and “30” for the
Group 3
b) Key in “5” that is the Command Code for making a deletion here
c) Key in the User ID that stored the User PIN, the lost EM card or the EM Card+User PIN
d) Press the # key. Two-beep confirms a valid entry and the PIN and/or Card in that User ID is cleared
ii) Delete an EM Card
10
5 #
(a) (b) (c) (d)
a) Key in the User Group that the EM Card belongs to. “1 0” for the Group 1, “2 0” for the Group 2, and “3 0” for the
Group 3
b) Key in “5” that is the Command Code for making a deletion here
c) Put the EM card close to the reader. One-beep confirms the reading. Read the Card only also makes a valid
deletion to the Card working with the Common User PIN or the Secondary User PIN
d) Press the # key. Two-beep confirms a valid entry. The EM Card in that User ID is cleared. Key in the User ID is not required.
6) Example 6 – Clear The Whole Group of Users :
Whole group of users including the PINs and Cards can be cleared with the following command.
10
0999
#
(a) (b) (c)
a) The User Group 1 – “10” is selected to be cleared. “20” for Group 2 & “30” for Group 3
b) Key in the Group Deletion Command, 0 9 9 9
c) Confirm the deletion with #. All the User PINs and Cards in the Group 1 are cleared. It takes few seconds to a
minute to complete depending on the data stored.
7) Example 7 – Report A Duress While Using EM Card :
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User PIN” or “EM Card +
Common User PIN” operation, they can be used to replace the “Secondary User PIN” or the “Common User PIN”
to operate the specific output and report a duress alarm event. Programming is not required. The system has this
function automatically while Duress Code exists.
Read Card
User ID
Read Card
Common User PIN
Read Card
29
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
CATHODE
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
MORE EGRESS
BUTTON CAN
BE CONNECTED
IN PARALLEL
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
(
-
)
N.O.
N.O.