User manual
APPLICATION HINTS FOR THE AUXILIARY TERMINALS
The tamper switch is Normally Closed while the keypad
is secured on the gang box. It is open when the keypad
is removed from the gang box. To get warning at
sabotage, connect the tamper switch to the TAMPER
terminal of the DA-2800. If more than one tamper
switches are connected, just connect them in series.
With the help of a Normally Closed door
position sensor (usually a magnetic door
switch) on the door to set up the following
functions:
Door Auto Relock -- The system will immediately
relock the door after a valid access has been gained to
prevent "tailgate" entries.
Door Forced-open Alarm -- The keypad will generate
alarm instantly if the door is forced to open. Enable the
function at Location 80.
Door Propped-up Alarm -- The keypad will generate
alarm if the door is left open longer than the pre-set
delay time. Enable the function at Location 81.
Inter-lock Control -- When the door is open, the
interlock output of the keypad will give a (
-
) command
to stop the other keypad in an inter-lock system.
Door Opening Alarm -- Door Opening Alarm is
designed for the emergency door only. It is always
given when the door is opened unless a valid user code
or card is used prior to the door is opened. Enable the
function at Location 91.
a)
b)
c)
d)
e)
(A) TAMPER N.C.
(B) DOOR SENS
The Alarm Output switches to (
-
) ground in door forced to open or the door open after Egress Delay. You may
use it to turn ON an LED lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally
Open protection zone of an alarm system. See Location 80 and Location 91 for more information about these
functions.
Only one connection option is recommended. Make sure that the sink current does not exceed the maximum
rating of 100mA.
(C) ALARM OUTPUT
GND(
-
)
N.C
TAMPER SWITCH
OF THE KEYPAD
GND(
-
)
DOOR
SENS
18
RECORD-DELETE PINS OR CARDS FOR OUTPUT 1, 2, & 3 (Locations 10, 20 & 30)
Total of 1,200 User PINs and/or Cards are available for the 3 user groups to control the 3 outputs.
1) 1,000 ---- for Output 1 (Group 1)
2) 100 ------ for Output 2 (Group 2)
3) 100 ------ for Output 3 (Group 3)
The Private User PINs and Cards in the 3 user groups MUST be unique. Repeated PINs will be rejected. Secondary User
PINs in the “EM Card + Secondary User PIN” can be repeated. See the Important Note --- Programming Criteria for
Codes in page 14 for more information.
USER GROUP LOCATIONS
– Group 1 --For User PINs/Cards Controlling Output 1
1,000 Users are allowed in group 1 for O/P 1
– Group 2 --For User PINs/Cards Controlling Output 2
100 Users are allowed in group 2 for O/P 2
– Group 3 -- For User PINs/Cards Controlling Output 3
100 Users are allowed in group 3 for O/P 3
SELECTION OF OPERATION MEDIA
Number 1, 2, 3 or 4 represents the Media to be used to operate the keypad.
Number 5 is the authorization code for deleting of an PIN and/or Card from
its User ID.
= EM Card only; = Private User PIN only;
= EM Card + Secondary User PIN = EM Card + Common User PIN
= Delete an User PIN &/or Card from the selected User ID number
= Clear all the PINs & Cards from the selected Location. It takes
few seconds to a minute to complete depending on the Location
selected and the data stored.Please see the programming example
below for the details.
USER ID NUMBER
A 3-digit ID is an identified number for each User PIN and/or Card.
Repeated ID number will be rejected by the system
a) ID Number
000
-
999
for 1,000 User PINs/Cards to operate Output 1
b) ID Number
001
-
100
for 100 User PINs/Cards to operate Output 2
c) ID Number
001
-
100
for 100 User PINs/Cards to operate Output 3
CARD &/OR USER PINS
The User PINs can be 4-8 digits. Key in the User PIN on each ID Number box, then confirm it with # key
Just simply put the EM card close to the reader window to read it on each ID Number box, then, confirm it with
# key if it is a Card ONLY, or Card + Common User PIN entry. The Common User PIN is NOT required to key-in
here. It will go into its location automatically after the Card is read.
Read the Card first, then key in the Secondary User PIN on each ID Number box, then confirm it with # key if it
is Card + Secondary User PIN. The Secondary User PINs can be duplicated or a proprietary User PIN but can
not be a duplicate of a Prime Code. Owner can use the same secondary User PIN for a group of Cards as a group
Common User Code (or called Department Code) for a specific relay output.
Cards (Operation Media # 1, 3, & 4) and Private User PINs (Operation Media 2) MUST be unique. A repeated EM
card or Private User PIN will be rejected and one long beep will be generated by the system to notify the owner.
10
-
30
1
-
5 000
-
999 #
10
20
30
1 2
3 4
5
0999
CARD &/OR USER PIN VALIDATIONLOCATIONS MEDIA USER ID
CARD &/OR USER PIN
27
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
INDIVIDUAL