User manual
The Duress Output switches to (
-
) ground when duress code is entered. You may use it to turn ON an LED
lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally Open protection zone of an
alarm system.
Only one connection option is recommended. Make sure that the sink current does not exceed the maximum
rating of 100mA.
(E) DURESS OUTPUT
The Key Active Output switches to (
-
) ground for 10
seconds whenever a key is touched. You may use
it to turn ON an LED lamp and /or a small buzzer to
notify a guard; or to energize a relay to switch ON
lights or trigger an CCTV Camera to start recording.
Make sure that the relay for switching ON lights
has high enough isolation between high voltage
and low voltage to prevent damage of the keypad.
Only one connection option is recommended. Make
sure the sink current does not exceed the maximum
rating of 100mA.
External power supply and isolation relay are strictly
necessary in driving high power device, such as
lights.
(D) KEY ACTIVE OUTPUT
(a) (b)
GND
(
-
)
DOOR
SENS
O/P 1
INHIB
INT.
LOCK
DU
OUT
GND
(
-
)
DOOR
SENS
O/P 1
INHIB
INT.
LOCK
DU
OUT
19
OPERATION AND FUNCTIONS OF THE SUPER USER PIN
1) Operate Output 1, 2, and 3
The operation of the Super User PIN is just like a normal User PIN. Simply key-in the PIN with a specific output
number for the desired Output. The Super User PIN can also be used to reset an operating output timer instantly.
---------- Output 1 Activates or Output 1 Resets
---------- Output 2 Activates or Output 2 Resets
---------- Output 3 Activates or Output 3 Resets
2) Inhibit The User PINs For Output 1
The Super User PIN can also be used to inhibit the normal User PINs/Cards for the Output 1 (usually they are for
door strike). It enhances the security level of the access control system, such as to stop a keypad after office hour
or while the house is nobody inside. Once the Output 1 is inhibited, the User PINs/Cards for it become invalid and
those people even know the User PINs are refused during the system is inhibited. The inhibit function is toggled in
Start / Stop mode with the following code entry.
---------- The Whole Group of User PINs & Cards for Output 1 are Disabled
or Enabled in Toggle
NOTE:
The inhibit function setting with the Super User PIN applies to the whole group of User PINs and Cards for
Output 1 ONLY, but not for Output 2 or Output 3.
For safety reason, the inhibit function initiated with the Super User PIN does not govern the Egress Button. The
door still can be opened with it from inside.
The Super User PINs are always valid. They are not governed by any inhibit or lock out function in the system.
RECORD THE COMMON USER PINS FOR OUTPUT 1, 2 & 3 (Locations 03, 04, & 05)
The Common User PINs 1, 2 and 3 are prepared for operating of the Output 1, Output 2 and Output 3 respectively as
an enhance code. The Common User PINs MUST work in the form of “Card + Common PIN” to operate the outputs to
increase the security of the access control system. See Locations 10, 20 & 30 for more information.
NOTE : Common User PIN alone can NOT be used to operate the Outputs directly.
COMMON USER PIN LOCATIONS
-- Location Stores The Common User PIN for Output 1
-- Location Stores The Common User PIN for Output 2
-- Location Stores The Common User PIN for Output 3
COMMON USER PINS
The Common User PIN can be 4 to 8 digits. Press # key to confirm the code entry.
When a new Common User PIN is keyed in and confirmed, the old one is replaced.
Example: Set a Common User PIN with the number of “1 3 5 7” for Output 1 ----
To deleted a Common User PIN from memory: Key in just the Location number and #. ----
4 to 8 Digits
SUPER USER PIN
SUPER USER PIN
SUPER USER PIN
SUPER USER PIN
COMMON USER PIN VALIDATIONLOCATIONS
#
1
#
2
#
3
#
9
03
1357
#
03
#
03
04
05
#
03
-
05
26
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
INDIVIDUAL