User manual
FEATURE PROGRAMMING & OPERATION INSTRUCTIONS
SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE
IMPORTANT NOTE:
1) DO NOT TURN OFF POWER while the keypad is in Programming Mode. Otherwise, it may cause data lost/error to the
programmed features in the memory.
2) The keypad beeps after power up. Wait 1 minute until the end of the power up delay, then key in the Master Code for
setting the system into programming mode.
3) For the owner’s convenience in programming at the first time, the factory has put a Master Code 0 0 0 0 into the
keypad (It is NOT a default code). To compromise security, in all cases, the owner should program a new Personal
Master Code to invalidate the factory set Master Code after the keypad is owned.
4) The Button has two functions in the keypads with Door Bell button. It is a door bell button while the keypad is in
normal operation; and it is equivalent to a
*
Button in programming mode.
MASTER CODE
The Master Code can be a factory set master code or the private master code that
was set by the owner.
Validate the master code with
* *
(or ) .
2-beep confirms a valid master code. The Mains LED (Amber) is constantly ON after the system is set in the
programming mode.
DIRECT ACCESS TO PROGRAMMING MODE WITH THE “DAP” CODE – 8 0 8 0
Set System Into Programming Mode With DAP Code In Case Of The Master Code Is Forgotten ! !
The owner requires to apply the following procedures precisely to set the system into programming mode
with the DAP code 8 0 8 0.
1) Switch OFF all the power for 1 minute to ensure that the system is fully discharged.
2) Swich ON power again. The system is in Power-up Mode for 1 minute and the buzzer gives beeps during the whole
period. This is the only time limit for setting the system to Direct Access to Programming (DAP).
3) Press the Egress Button (EG IN) once first to enable the DAP function.
4) Key in the DAP Code 8 0 8 0 and validate it with
* *
(or ), the existing Master Code in the memory is
erased and the power up beep stops. The keypad turns itself into programming mode like using the Master Code and
it is ready to accept the new programming data.
5) If the Egress Button is not pressed and the DAP code is not keyed in within the power up period, the system will set
itself to normal operation mode. To set it back to power-up mode, repeat procedures 1-4.
DAP CODE
The DAP code is fixed on 8 0 8 0 and it is valid only in the Power-up Period after the Egress Button is pressed.
Validate the DAP code with the
* *
(or )
.
2-beep confirms the system is in the Programming Mode; and the Mains LED is constantly ON.
See “RECORD A MASTER CODE” at “Location 01” for the details of programming a new master code.
NOTE:
If the keypad is linking up with the DA-2800 controller in the Split-decoded operation, it is necessary to put the
controller’s “Link-up Jumper” to “ON” position to get the new Master Code for it. As the Master Code is also the link-up
code of the two units. Do Not Forget to put the Link-up jumper back to OFF position after the programming. Otherwise,
the controller will accept other keypads to link up with it.
0000
8080
**
**
MASTER CODE VALIDATION
DAP CODE VALIDATION
.
.
.
.
.
.
.
10
35
PROGRAMMING SUMMARY CHART
LOCATION
FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
0 1
Master Code 4-8 Digits
01
MASTER CODE
#
NIL
0 2
Super User PIN 4-8 Digits
02
SUPER USER PIN
#
NIL
0 3
Common User PIN for O/P 1
4-8 Digits
03
COMMON USER PIN 1
#
NIL
0 4
Common User PIN for O/P 2
04
COMMON USER PIN 2
#
NIL
0 5
Common User PIN for O/P 3
05
COMMON USER PIN 3
#
NIL
1 0
User PINs / Cards for O/P 1
CODE 1
-
MEDIA:
1---EM Card
2---Private User PIN
3---EM Card+Sec User PIN
4---EM Card+Com User PIN
5---Deletion of User PIN
CODE 2
-
USER ID:
000-999---Group 1(10)
001-100---Group 2(20)
001-100---Group 3(30)
CODE 3
-
USER PINs / Cards:
4-8 Digits / Cards
10
CODE1
CODE2
CODE3
#
NIL
2 0
User PINs / Cards for O/P 2
20
CODE1
CODE2
CODE3
#
NIL
3 0
User PINs / Cards for O/P 3
30
CODE1
CODE2
CODE3
#
NIL
4 0
Visitor Codes
CODE 1
-
VISITOR ID: 01-50
CODE 2
-
VALID PERIOD:
00---One Time
01-99 Hours
CODE 3
-
VISITOR CODE:
4-8 Digits
40
CODE1
CODE2
CODE3
#
NIL
4 1
Duress Code for O/P 1
CODE ID
-
O/P 1: 01-50
CODE ID
-
O/P 2: 01-10
CODE ID
-
O/P 3: 01-10
DURESS CODE: 4-8 Digits
41
CODE ID
DURESS CODE
#
NIL
4 2
Duress Code for O/P 2
42
CODE ID
DURESS CODE
#
NIL
4 3
Duress Code for O/P 3
43
CODE ID
DURESS CODE
#
NIL
5 1
O/P Mode for O/P 1
OUTPUT MODE & TIME:
0--- Start / Stop
1---99999 Seconds,
Momentary
51
O/P MODE & TIME
#
5 Seconds
5 2
O/P Mode for O/P 2
52
O/P MODE & TIME
#
5 Seconds
5 3
O/P Mode for O/P 3
53
O/P MODE & TIME
#
5 Seconds
6 0
Personal Safety & Lock-out
LOCK-OUT CODE:
1---10 Trial, Lock-out 60 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Out 15
Minutes
00---No Lock-out
60
LOCK-OUT CODE
#
Code = 1,
10 Trials,
Lock-out 60
Seconds
7 0
PIN Entry Mode
ENTRY MODE:
1---Auto Mode
2---Manual Mode
70
ENTRY MODE
#
Mode = 2,
Manual Mode
7 1
Pacifier Tone ON-OFF
FUNCTION MODE:
0---OFF
1---ON
71
FUNCTION MODE
#
Mode = 1,
Pacifier Tone
ON
7 2
Output Announcer
72
FUNCTION MODE
#
Mode = 1
Announcer ON
7 3
Standby LED Flashing
73
FUNCTION MODE
#
Mode = 1,
Flashing On
EGRESS BUTTON
PRESS ONCE