User manual
EXAMPLES:
Example 1: Set Egress Button in Momentary contact 5 seconds with delay & warning beep
90
2
5
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact with warning, (c) Delay time of 5 seconds to release door,
(d) Entry confirmation
Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep
90
5
10
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10 seconds to release
door, (d) Entry confirmation
Example 3: Set Egress Button in Momentary contact without delay (This is the default setting)
90
1
0
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly, (d) Entry
confirmation
DOOR OPENING ALARM & TIMER (Location 91)
ALARM & TIMING OF DOOR OPENING
0
--- No Alarm – (Default)
The Alarm Output is disabled
1
–
999
--- Alarm Timer
The Door Open Alarm operates the Alarm Output (Terminal 13) only. It is mainly prepared to trigger an optional alarm
system. Put any Timing Figure of 1 to 999 into the box to enable the function of the Door Opening Alarm. The figure
is the time in second of the alarm duration, which starts to count after the door is opened and it resets automatically
when the time reaches.
The alarm can be stopped with the User Codes/Cards or the Super User PIN for Output 1 at any time before the end
of the alarm time.
NOTE: The Door Opening Alarm is designed to protect the emergency exit door from use by the un-authorized person.
The alarm occurs when the door is opened or forced to open. However, Alarm will not happen if the door is opened with
a valid User Code or Card.
The Manner of The Door Opening Alarm:
a) The door is forced to open without using PIN/Card – Alarm
b) The door is opened with Egress Button – Alarm
c) The door is opened with PIN/Card – No Alarm
To prevent confusion of the alarm outputs. It is suggested to disable the "Door Forced Open Warning" at Location 80
while "Door Opening Alarm" function is enabled. If both functions at Location 80 and Location 91 are enabled and are
set with different timings, the system will combine them and will take the longer one for alarm time.
CLOSE THE PROGRAMMING MODE (
* *
)
Always close programming mode with
* *
to set system back to normal Operation after programming.
The button is equivalent to the
*
button in the keypad with bell button.
VALIDATION
**
------------------------------- System is back to normal operation mode
ALARM TIME VALIDATIONLOCATION
0
or
1
-
99991 #
.
28
RECORD-DELETE PINS OR CARDS FOR OUTPUT 1, 2, & 3 (Locations 10, 20 & 30)
Total of 1,200 User PINs and/or Cards are available for the 3 user groups to control the 3 outputs.
1) 1,000 ---- for Output 1 (Group 1)
2) 100 ------ for Output 2 (Group 2)
3) 100 ------ for Output 3 (Group 3)
The Private User PINs and Cards in the 3 user groups MUST be unique. Repeated PINs will be rejected. Secondary User
PINs in the “EM Card + Secondary User PIN” can be repeated. See the Important Note --- Programming Criteria for
Codes in page 14 for more information.
USER GROUP LOCATIONS
– Group 1 --For User PINs/Cards Controlling Output 1
1,000 Users are allowed in group 1 for O/P 1
– Group 2 --For User PINs/Cards Controlling Output 2
100 Users are allowed in group 2 for O/P 2
– Group 3 -- For User PINs/Cards Controlling Output 3
100 Users are allowed in group 3 for O/P 3
SELECTION OF OPERATION MEDIA
Number 1, 2, 3 or 4 represents the Media to be used to operate the keypad.
Number 5 is the authorization code for deleting of an PIN and/or Card from
its User ID.
= EM Card only; = Private User PIN only;
= EM Card + Secondary User PIN = EM Card + Common User PIN
= Delete an User PIN &/or Card from the selected User ID number
= Clear all the PINs & Cards from the selected Location. It takes
few seconds to a minute to complete depending on the Location
selected and the data stored.Please see the programming example
below for the details.
USER ID NUMBER
A 3-digit ID is an identified number for each User PIN and/or Card.
Repeated ID number will be rejected by the system
a) ID Number
000
-
999
for 1,000 User PINs/Cards to operate Output 1
b) ID Number
001
-
100
for 100 User PINs/Cards to operate Output 2
c) ID Number
001
-
100
for 100 User PINs/Cards to operate Output 3
CARD &/OR USER PINS
The User PINs can be 4-8 digits. Key in the User PIN on each ID Number box, then confirm it with # key
Just simply put the EM card close to the reader window to read it on each ID Number box, then, confirm it with
# key if it is a Card ONLY, or Card + Common User PIN entry. The Common User PIN is NOT required to key-in
here. It will go into its location automatically after the Card is read.
Read the Card first, then key in the Secondary User PIN on each ID Number box, then confirm it with # key if it
is Card + Secondary User PIN. The Secondary User PINs can be duplicated or a proprietary User PIN but can
not be a duplicate of a Prime Code. Owner can use the same secondary User PIN for a group of Cards as a group
Common User Code (or called Department Code) for a specific relay output.
Cards (Operation Media # 1, 3, & 4) and Private User PINs (Operation Media 2) MUST be unique. A repeated EM
card or Private User PIN will be rejected and one long beep will be generated by the system to notify the owner.
10
-
30
1
-
5 000
-
999 #
10
20
30
1 2
3 4
5
0999
CARD &/OR USER PIN VALIDATIONLOCATIONS MEDIA USER ID
CARD &/OR USER PIN
17