USER PIN ENTRY MODE – Auto or Manual (Location 70)
USER PIN ENTRY MODES
Two modes 1 and 2 are available for User PIN entry options. The EM Card is always in Auto Entry Mode and is not
affected by the selection here.
1
--- Auto Entry Mode
Auto Entry Mode requires no pressing of the
#
key following the User PIN for code checking.
In the Auto Entry Mode, the User PINs MUST be set in the same digit length of the Master Code (For example, if
the Master Code is 5 digits, then all User PINs must be in 5 digits as well. All other User PINs not in 5 digits become
invalid). When the number of digits reaches, the system will check the User PIN automatically. Good for high traffic
access control.
2
--- Manual Entry Mode – (Default)
Manual Entry Mode always requires the
#
key following of the User PIN for code checking. The User PINs can be 4-8
digits arbitrary and they are NOT required to be in the same digit length of the Master Code. Manual Entry increases
the level of security in the code trial by the unauthorized people.
PACIFIER TONES ON-OFF SELECTION (Location 71)
PACIFIER TONES ON-OFF MODES
The Pacifier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry (1 beep), the
Output Operation Announcer (2 beeps or 1 long beep) and the Unsuccessful User Code/Card entry (5 beeps).
NOTE :
The beeps for the Warning and the Power-up Delay do not belong to pacifier tones and can not be set to OFF.
1
--- Pacifier Tone ON – (Default)
All the Pacifier Tones available from the keypad are enabled. They are the response tones indicating the operation
status of the keypad after the Card/User Code is entered.
0
--- Pacifier Tone OFF
All the Pacifier Tones are OFF. Good for place needs for a silent environment.
OUTPUT OPERATION ANNOUNCER (Location 72)
OUTPUT OPERATION ANNOUNCER
The announcer gives notification beep to the users and the visitors on the operation status of the outputs. There are
two notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF mode in the
Location 71 is selected.
1
--- 1 Second Long Notification -- (Default)
1 second notification beep is given when the output relay is activated with a valid Card/Code or Egress Button. It is
prepared to notify the person outside the door when the lock is released and the door can be opened. It is good for
the door lock device gives no sound when it activates, such as a magnetic lock.
0
--- 2 Short Beeps Notification
2 short beeps notification is given when the output is activated with a valid Card/Code.
FUNCTION MODES VALIDATIONLOCATION
FUNCTION MODES VALIDATIONLOCATION
1
or
0
1
or
0
#
#
71
72
24
Example 3: Delete a “Visitor Code” from Vistor ID
02
in the memory
40
02 #
(a) (b) (c)
(a) Visitor Code Programming, (b) The Visitor ID, (c) Delete Confirmation
Example 4: Clear all “Visitor Codes” from Location
40
40
0999 #
(a) (b) (c)
(a) Visitor Code Location, (b) The Deletion Command Code, (c) Confirmation, all Visitor Codes are cleared
DURESS CODES (FOR OUTPUTS 1, 2 & 3) (Location 41, 42 & 43)
The Duress Codes are prepared for those Important Persons in case of DURESS while he operates the access control
keypad. The duress code operates like a normal User PIN for Output 1, 2 or 3, and at the same time activates the
Duress Output without any indication. The user may use it to report an emergency and ask for help silently when he is
forced to operate the keypad if the Duress Output is connected with a security system.
NOTE: The Duress Codes are always valid. They are not governed by any inhibit or lock-out function in the system.
OUTPUT LOCATIONS
41
– Duress Codes for Output 1
42
– Duress Codes for Output 2
43
– Duress Codes for Output 3
DURESS CODE IDs
ID
01
-
50
50 Duress Codes Are Allowed for The Output 1
ID
01
-
10
10 Duress Codes Are Allowed for The Output 2
ID
01
-
10
10 Duress Codes Are Allowed for The Output 3
0999
= Clear all the Duress Codes from the selected Location group.
Please see the programming example below for the details.
THE DURESS CODES
50, 10 and 10 Duress Codes can be programmed for Output 1, 2 and 3 respectively. They are stored in their two-digit
Code ID box. When a new Code is put into the same Code ID box, the old code is replaced.
The Duress Codes are 4-8 digits for Manual Mode code entry.
The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
Always set a Duress Code that is easy to remember in Panic Situation. Only one number different from the daily
used User PIN is highly recommended.
Example: User PIN is 1 3 6 9, then 3 3 6 9 or 1 3 6 0 might be a good choice for the Duress Code.
The Duress Code can also be used to replace the Secondary User PIN or Common User PIN in Card reading for
the Duress reporting.
EXAMPLES:
Example 1: Set a “Duress Code” with the number of “3 3 6 9” for Output 1
41
01
3369
#
(a) (b) (c) (d)
(a) Duress Code Programming for Output 1, (b) Duress Code ID, (c) The Duress Code, (e) Entry Confirmation
41
-
43
01
-
50
#
4
-
8 DIGITS
DURESS CODE VALIDATIONLOCATIONS CODE ID
21