User manual

40
THE PROGRAMMING SUMMARY CHART --- (Supplementary Information)
LOCATION
FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
0 1
Master Code 4-8 Digits
01
MASTER CODE
#
NIL
0 2
Super User PIN 4-8 Digits
02
SUPER USER PIN
#
NIL
0 3
Common User PIN for O/P 1
4-8 Digits
03
COMMON USER PIN 1
#
NIL
0 4
Common User PIN for O/P 2
04
COMMON USER PIN 2
#
NIL
0 5
Common User PIN for O/P 3
05
COMMON USER PIN 3
#
NIL
1 0
User PINs / Cards for O/P 1
CODE 1
-
MEDIA:
1---EM Card
2---Private User PIN
3---EM Card+Sec User PIN
4---EM Card+Com User PIN
5---Deletion of User PIN
CODE 2
-
USER ID:
000-999---Group 1(10)
001-100---Group 2(20)
001-100---Group 3(30)
CODE 3
-
USER PINs / Cards:
4-8 Digits / Cards
10
CODE1
CODE2
CODE3
#
NIL
2 0
User PINs / Cards for O/P 2
20
CODE1
CODE2
CODE3
#
NIL
3 0
User PINs / Cards for O/P 3
30
CODE1
CODE2
CODE3
#
NIL
4 0
Visitor Codes
CODE 1
-
VISITOR ID: 01-50
CODE 2
-
VALID PERIOD:
00---One Time
01-99 Hours
CODE 3
-
VISITOR CODE:
4-8 Digits
40
CODE1
CODE2
CODE3
#
NIL
4 1
Duress Code for O/P 1
CODE ID
-
O/P 1: 01-50
CODE ID
-
O/P 2: 01-10
CODE ID
-
O/P 3: 01-10
DURESS CODE: 4-8 Digits
41
CODE ID
DURESS CODE
#
NIL
4 2
Duress Code for O/P 2
42
CODE ID
DURESS CODE
#
NIL
4 3
Duress Code for O/P 3
43
CODE ID
DURESS CODE
#
NIL
5 1
O/P Mode for O/P 1
OUTPUT MODE & TIME:
0--- Start / Stop
1---99999 Seconds,
Momentary
51
O/P MODE & TIME
#
5 Seconds
5 2
O/P Mode for O/P 2
52
O/P MODE & TIME
#
5 Seconds
5 3
O/P Mode for O/P 3
53
O/P MODE & TIME
#
5 Seconds
6 0
Personal Safety & Lock-out
LOCK-OUT CODE:
1---10 Trial, Lock-out 60 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Out 15
Minutes
00---No Lock-out
60
LOCK-OUT CODE
#
Code = 1,
10 Trials,
Lock-out 60
Seconds
7 0
PIN Entry Mode
ENTRY MODE:
1---Auto Mode
2---Manual Mode
70
ENTRY MODE
#
Mode = 2,
Manual Mode
7 1
Pacifier Tone ON-OFF
FUNCTION MODE:
0---OFF
1---ON
71
FUNCTION MODE
#
Mode = 1,
Pacifier Tone
ON
7 2
Output Announcer
72
FUNCTION MODE
#
Mode = 1
Announcer ON
7 3
Standby LED Flashing
73
FUNCTION MODE
#
Mode = 1,
Flashing On
SPECIFICATIONS
Operating Voltage:
12V-24V DC, Auto Adjusting
Operating Current:
65mA (quiescent) to 100mA (three relays active)
Operating Temperature:
-20 C to +70 C
Environmental Humidity:
5-95% relative humidity non-condensing
The Adjustable Timer for Output 1:
1-30 Seconds
Power Up Delay:
5 Seconds
Tamper Alarm:
3 Minutes
Input Sensing Terminals:
a) Door position, b) Egress, c) O/P 1 Inhibit, d) Door Bell, e) Tamper
Output Control Terminals:
a) Duress, b) Alarm, c) Key Active, d) Inter-lock;
Transistor Open Collector, 24VDC/100mA sink Max
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Output Relay 3 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Dimensions:
32.5(H) X 120(W) X 87(D)mm Plastic Box
Weight:
250g net
RF Remote Controller (DA-2800 Only) :
Number of Self-leaning Codes : Over 1 Million
Number of RF Control Keys : 40 Maximum
4 Control Channels : Output 1, 2, 3 & Door Chime
Operation Frequency : 433MHz
Control Distance : 60 Meters Approx. in Open Space
Receiver Type : Super-heterodyne
Operation Voltage : 12V Alkaline Battery, Type 27A (Battery Not Included)
Weight : 32g
Specifications are subject to change for modification without notice
PACKAGE CONTENTS
• One Access Controller
• One Pack of Mounting Screws
• Two RF Remote Control Keyfobs (DA-2800 Only), Battery Not Included
• One Owner’s Manual
5