User manual

THE SPLIT-DECODED CONTROLLER UNIT (Figure 1)
THE MAIN CIRCUIT BOARD OF THE CONTROLLER --- (Figure 2)
NOTE:
Factory suggest that the work of timer adjustment and change of jumper settings on the main circuit board are
to be done by the Installer only.
No adjustment/setting change is required for Split-decoded operation with the ex-factory settings.
6
LINK-UP JUMPER
OFF-->ON-->OFF
CODE LEARNING
BUTTON
(DA-2800 ONLY)
REMOTE CONTROL
SIGNAL & STATUS
(DA-2800 ONLY)
INTERNAL SIREN
& DOOR CHIME
CONNECTION
TERMINALS
MAINS
OUTPUT BEEP JUMPER
ON OR OFF
FUNCTION MODE JUMPER
1. SPLIT-DECODED
2. STAND ALONE MODE 1
3. STAND ALONE MODE 2
ADJUSTABLE TIMER
FOR OUTPUT 1
TURN CLOCKWISE FOR
MAXIMUM TIME
RECEIVER FOR
REMOTE CONTROL
(DA-2800 ONLY)
CLOSE THE PROGRAMMING MODE (
* *
)
Always close programming mode with
* *
to set system back to normal Operation after programming.
The button is equivalent to the
*
button in the keypad with bell button.
VALIDATION
**
--------------- System is back to normal operation mode
THE OPERATION MODES AND THE WIEGAND OUTPUT (Location 94)
Four operation modes are available for the selection. The codes are 0, 1, 2 and 3.
WIEGAND OUTPUT AT KEYPAD OPERATION MODE
0 --- Stand Alone Keypad Mode -- (Default)
The system provides full functions to operate its outputs and at the same time provides Wiegand Data Output for all the
VALID Cards and User PINs including the Duress Codes and Visitor Codes. No Wiegand Data Output for the invalid PINs
and Cards.
1 --- Card & Code Reader Mode
In the Card & Code Reader Mode, the keypad provides Wiegand Data Output for all the Card readings and PINs/Code
entries but does not operate its outputs. It is solely a card and code reader.
NOTE:
It is suggested to clean all the codes, PINs and cards that were previously stored in the system before setting the
system for reader mode.
2 --- Master Keypad of Split-Decoded Mode (The Only Mode will Send Out the Link-up Code)
The keypad unit provides the Wiegand Data Output for the valid user PINs, Codes and Cards exactly like in the Stand
Alone Mode. The Master keypad will transfer all the programmed feature data (except the user PINs, Codes and Cards
data) to the Access Controller (decoder) right after it exits the programming mode. A Split-decoded keypad system
needs at least one Master keypad and one Access Controller to work.
3 --- Slave Keypad of Split-Decoded Mode
The Keypad unit provides the Wiegand Data Output for the valid user PINs, Codes and Cards exactly like in Stand Alone
Mode. No feature data is transferred to the Access Controller (decoder) from the Slave keypad. It takes the same feature
data from the Master keypad to operate. The Slave keypad(s) is for a Split-Decoded system that needs more than one
keypads for operation convenience.
NOTE:
a) Do not set more than one keypads in Master mode in a Split-Decoded system. Otherwise, the data will be confused.
b) Each keypad in Split-Decoded mode can be programmed independently with its own user PINs, Codes and Cards.
The PINs, Codes and Cards can be repeatedly used in other keypads in the same system.
OPERATION MODELOCATION VALIDATION
#0
,
1
,
2
or
394
39
.
INDIVIDUAL
INDIVIDUAL