User manual

EXAMPLES:
Example 1: Set Egress Button in Momentary contact 5 seconds with delay & warning beep
90
2
5
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact with warning, (c) Delay time of 5 seconds to release door,
(d) Entry confirmation
Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep
90
5
10
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10 seconds to release
door, (d) Entry confirmation
Example 3: Set Egress Button in Momentary contact without delay (This is the default setting)
90
1
0
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly, (d) Entry
confirmation
DOOR OPENING ALARM & TIMER (Location 91)
ALARM & TIMING OF DOOR OPENING
0
--- No Alarm – (Default)
The Alarm Output is disabled
1
999
--- Alarm Timer
The Door Open Alarm operates the Alarm Output (Terminal 13) only. It is mainly prepared to trigger an optional alarm
system. Put any Timing Figure of 1 to 999 into the box to enable the function of the Door Opening Alarm. The figure
is the time in second of the alarm duration, which starts to count after the door is opened and it resets automatically
when the time reaches.
The alarm can be stopped with the User Codes/Cards or the Super User PIN for Output 1 at any time before the end
of the alarm time.
NOTE: The Door Opening Alarm is designed to protect the emergency exit door from use by the un-authorized person.
The alarm occurs when the door is opened or forced to open. However, Alarm will not happen if the door is opened with
a valid User Code or Card.
The Manner of The Door Opening Alarm:
a) The door is forced to open without using PIN/Card – Alarm
b) The door is opened with Egress Button – Alarm
c) The door is opened with PIN/Card – No Alarm
To prevent confusion of the alarm outputs. It is suggested to disable the "Door Forced Open Warning" at Location 80
while "Door Opening Alarm" function is enabled. If both functions at Location 80 and Location 91 are enabled and are
set with different timings, the system will combine them and will take the longer one for alarm time.
ALARM TIME VALIDATIONLOCATION
0
or
1
-
99991 #
38
INSTALLATION
PRECAUTIONS
1) Installation Location:
The built-in receiver of the Access Controller is working at the UHF frequency band of 433Mhz. To get the best
receiving result of the signals from the remote keys a correct installation location is necessary.
i) Install it on a location inside the house facing to the open space and there has no strong electro-magnetic wave
signals near it.
ii) Do not install it in a concrete room or under a concrete stair, which shortens the control distance.
2) Prevent Accidental Short Circuit:
In the previous experience, most of the damages caused in the installation are accidental touching of the components
on circuit board with the wires carrying power. Please be patient in the installation. Study the manual to become
familiar with the specifications of the system beforehand is also important.
i) Do not apply power to the system while it is in installation.
ii) Check carefully all the wirings are correct before applying power to the system for testing.
SPLIT-DECODED MODE -- (for DA-2800 & DA-2801)
Split-decoded Mode needs at least one keypad to work with the decoder. The decoder decodes all the commands
from the keypad to operate its outputs. It is an unique solution to immediately up-grade a general purpose keypad to a
high security access control system. All the keypads in the DK-2800 series with Data I/O Port are compatible with the
decoder. A Split-decoded system divides itself into the outside keypad unit and the inside decoder unit. Any sabotage to
the outside unit does not affect the security of the inside unit.
7
RF WIRELESS
REMOTE CONTROL (DA-2800 ONLY)
DOOR LOCK
(OUTPUT 1)
SECURITY
SYSTEM (OUTPUT 2)
AUTOMATIC
OPERATOR (OUTPUT 3)
COMMON
GROUND
COMMON
GROUND
DA-2800 OR DA-2801
SLAVE 1
SLAVE 2
MASTER
DATA I/O
COMMON
GROUND
DATA I/O
DATA I/O
MAXIMUM 3 KEYPADS CAN BE CONNECTED IN PARALLEL
MASTER