User Manual
The home technology brand for the entire house. More information at www.sygonix.com
36
d) Changing or creating user codes
To create or change a user code, enter the following combination:
✱ XX USER # XX = storage position number 01 - 19
USER = user code (4 - 8 digits)
✱ 6XX USER # XX = storage position numbers 20 - 99
USER = user code (4 - 8 digits)
Please note that the master code and the user codes must have the same
number of signs. If you use a master code with four digits, then all the user
codes must also have four digits.
e) Deleting user codes
To delete a user code, enter the following combination:
✱ 50 XX # XX = storage position number 01 - 99
To delete all user codes, enter “00” in-
stead of the storage position number.
f) Setting the LOCK-OUT activation time (factory setting = 05)
You can defi ne the activation time of the “Lock Out” relay contacts.
If 00 is set, the relay contacts remain activated until the user code is en-
tered again. To set the activation time, enter the following combination:
✱ 20 TT # TT = 01-99 seconds
TT = 00 (LOCK-OUT remains activated un-
til the user code is entered again)
g) Key lock (factory setting = key lock disabled)
If the automatic key lock is activated, the code lock automatically locks all
buttons for 30 seconds after a user password or the master code has been
entered incorrectly 5 times or if 20 wrong characters were entered subse-
quently.
To generally activate or deactivate the automatic key lock, enter the fol-
lowing combination:
✱ 51 #
49
Signalisations optiques et acoustiques des LED d’état
Etat Signali-
sation
acoustique
LED
«rouge/
orange»
(A)
LED
«vert»
(B)
LED
«jaune»
(C)
Mise en service 3x bips (bref
intervalle)
S'allume en
rouge
Pendant le fonction-
nement
S'allume en
rouge
Appel du
mode de program-
mation
3x bips
(intervalle
long)
S'allume en
orange
En mode de pro-
grammation
S'allume en
orange
Mot de passe utili-
sateur correct
S´allume
en vert
Rappel «Door Lock»
(la porte est ouverte
plus longtemps que
le réglage de la mi-
nuterie des contacts
relais «Lock Out»).
Le LED vert clignote
également si la ligne
de raccordement
REED n'est pas
pontée avec le rac-
cordement «COM(-)»
ou si aucun contact
magnétique n'a été
raccordé.
Clignote
Mot de passe AUX
correct
s'al-
lume