Intended use
With the radio remote control suitable receivers of the RS2W radio
system (or other consumers connected) can be switched on or off
wirelessly. The operation of the radio remote control is via a battery
of the type “CR2032”.
A special feature gives the radio remote control via LED a feedback,
whether the programmed radio receiver (max. 5 each per channel)
of the RS2W radio system has received the key commands or not.
It is intended for indoor use only. Do not use it outdoors. Contact with
moisture, e.g. in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or mo-
dify this product. If you use the product for purposes other than those
described above, the product may be damaged. In addition, improper
use can cause hazards such as short circuiting, re etc. Read the
instructions carefully and keep them. Make this product available to
third parties only together with its operating instructions.
This product complies with the statutory national and European requi-
rements. All company names and product names are trademarks of
their respective owners. All rights reserved.
Safety instructions
Read the operating instructions carefully and espe-
cially observe the safety information. If you do not fol-
low the safety instructions and information on proper
handling in this manual, we assume no liability for any
resulting personal injury or damage to property. Such
cases will invalidate the warranty/guarantee.
a) General
The device is not a toy. Keep it out of the reach of children and pets.
Do not leave packaging material lying around carelessly. This may
become dangerous playing material for children.
Protect the product from extreme temperatures, direct sunlight,
strong jolts, high humidity, moisture, ammable gases, vapours and
solvents.
Do not place the product under any mechanical stress.
If it is no longer possible to operate the product safely, take it out of
operation and protect it from any accidental use. Safe operation can
no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions
or
- has been subjected to any serious transport-related stresses.
Please handle the product carefully. Jolts, impacts or a fall even
from a low height can damage the product.
Also observe the safety and operating instructions of any other de-
vices which are connected to the product.
Do not use this product in hospitals or medical institutions. Although
transmitters of the RS2W system only emit relatively weak radio si-
gnals, these may lead to the malfunctioning of life-support systems.
The same may also apply to other areas.
The product must not get damp or wet!
Consult an expert when in doubt about operation, safety or connec-
tion of the device.
Maintenance, modications and repairs are to be performed
exclusively by an expert or at a qualied shop.
If you have questions which remain unanswered by these operating
instructions, contact our technical support service or other technical
personnel.
b) Batteries
Correct polarity must be observed while inserting the batteries.
Batteries should be removed from the device if it is not used for a
long period of time to avoid damage through leaking. Leaking or
damaged batteries might cause acid burns when in contact with
skin, therefore use suitable protective gloves to handle corrupted
batteries.
Batteries must be kept out of reach of children. Do not leave batte-
ries lying around, as there is risk, that children or pets swallow them.
All batteries should be replaced at the same time. Mixing old and
new batteries in the device can lead to battery leakage and device
damage.
Batteries must not be dismantled, short-circuited or thrown into
re. Never recharge non-rechargeable batteries. There is a risk of
explosion!
Latest operating instructions
Download the latest operating instructions via the
link www.conrad.com/downloads or scan the QR
code shown. Follow the instructions on the website.
Explanation of symbols
An exclamation mark in a triangle indicates important ins-
tructions in this operating manual that absolutely have to
be observed.
The arrow symbol indicates specic tips and advice on
operation.
Delivery content
RS2W wireless remote control
Battery CR2032
Operating instructions
Operating instructions
RS2W radio remote control,
12 channels
Item no. 1761760 (white)
Item no. 1761761 (black)
Operating elements
1
2
3
4
5
1 LED (red/blue)
2 Button “ON” (power on) and
“OFF” (power off) for 3 channels
per level
3 Button “ALL ON” (all 3 channels of
the current level power on) and
“ALL OFF” (all 3 channels of the
current level power off)
4 Slide switch to select the 4 levels
(I, II, III, IV)
5 Removable battery holder (for a
battery of the type “CR2032”)
Inserting/replacing the battery
Delivery includes a CR2032 type battery. This is possibly
already inserted in the battery compartment. A plastic
protective strip between the battery and battery contacts
here prevents premature discharge; remove it.
To insert/replace the battery pull the battery holder (5) down and
out.
Then place a type CR2032 battery inside, observing the correct po-
larity. The positive pole of the battery has to be in the direction of “+”
mark on the battery holder.
Slide the battery holder back in the correct orientation in the radio
remote control.
A battery change is required if the range of the radio re-
mote control decreases signicantly or the LED (1) does
not light up anymore when the buttons are pressed.
Operation
Keep between the radio remote control and the radio re-
ceiver used a minimum distance of 20 - 30 cm.
a) Reset the radio remote control
At initial startup, you should for each channel used (1, 2, ...., 11 or 12)
perform a reset rst, and only then program the radio receiver.
A reset also deletes all of the radio receivers programmed/saved on
the respective channel.
The reset applies only to the respective individual channel
- all other 11 channels are unimpaired!
Proceed as follows to perform a reset of a channel:
First select the slide switch to the correct switching group (I, II, III,
IV) for the selected channel to reset.
Keep both buttons (“ON” and “OFF”) of the corresponding channel
pressed so long (about 3 seconds) until the LED (1) ashes red
(then release buttons for 1 - 2 seconds).
Once again keep both buttons (“ON” and “OFF”) pressed (about 6
seconds) until the LED (1) ashes blue. Then release both buttons.

Summary of content (2 pages)