15. Technical Data
Supply voltage: 230 V/AC, 50 Hz
Connected load: 3680 W (230 V/AC, 16 A)
Temperature switching points: Max. 7 per day
Temperature control area: -20 °C to +70 °C
(basic setting +5.0 to +45.0 °C,
adjustable via function G7
“TEMP LIMITS”)
Frost protection function: Yes (can be activated/deacti-
vated)
Scale protection function: Yes (can be activated/deacti-
vated)
Switching contact: Relay, single-pole
Dimensions: 75 x 130 x 37.5 mm (W x H x D,
no plug)
Weight: 340 g (incl. cable)
Sensor cable length: Approx. 2 m
Protective degree for sensor/cable:
IP68
Attention!
The protection class IP68 applies only for the sensor or
cable but not for the housing of the universal thermo-
stat as such.
It must not become damp or wet. There is danger to life
from a fatal electric shock!