Operation Manual

16. Electrical Equipment
16-7
Voltage Check
With a digital voltage meter or multi-meter to
measure battery voltage.
Voltage:
Fully charged: 13.0 ~ 13.2V (at 20)
Undercharged: Below 12.3 V (at 20)
CHARGING
Connect the Charger positive (+) to the battery
positive (+) terminal.
Connect the Charger negative (-) to the battery
negative (-) terminal.
Standard Max.
Charging current
0.4A 4.0A
Charging time
5~10H 1H
Caution
Strictly keep flames away from a charging
battery.
The charging ON/OFF is controlled by the
charger’s switch. Do not control the
charging by battery jump wires.
Turn the charger’s switch OFF at first before
or after charging to prevent from sparks
created on the couplers and explosion.
To charge a battery must be based on the
battery’s ampere-hour shown on label.
Caution
Quick charge a battery should be used only
in an emergency.
Make sure the current and charging time of
above description.
The battery will be damaged by too much
current or too rush charging.
When finishing charge, it is necessary to
measure voltage after 30 minutes.
After installing the battery, coat the terminals with
clean grease.