Operation Manual
16. Electrical Equipment
16-7
Voltage Check
With a digital voltage meter or multi-meter to
measure battery voltage.
Voltage:
Fully charged: 13.0 ~ 13.2V (at 20℃)
Undercharged: Below 12.3 V (at 20℃)
CHARGING
Connect the Charger positive (+) to the battery
positive (+) terminal.
Connect the Charger negative (-) to the battery
negative (-) terminal.
Standard Max.
Charging current
0.4A 4.0A
Charging time
5~10H 1H
Caution
● Strictly keep flames away from a charging
battery.
● The charging ON/OFF is controlled by the
charger’s switch. Do not control the
charging by battery jump wires.
● Turn the charger’s switch OFF at first before
or after charging to prevent from sparks
created on the couplers and explosion.
● To charge a battery must be based on the
battery’s ampere-hour shown on label.
Caution
● Quick charge a battery should be used only
in an emergency.
● Make sure the current and charging time of
above description.
● The battery will be damaged by too much
current or too rush charging.
● When finishing charge, it is necessary to
measure voltage after 30 minutes.
After installing the battery, coat the terminals with
clean grease.