User's Manual
Harmonics @P1dB GCP
Including filter
-70 dBc
Spurious Signals -70 -60 dBc
Operating Voltage 22.8 24 25.2 Volts
Supply Current @ Pout=25
watts (Idcq = 200 mA)
3 Amps
Environmental Specifications
Parameter Min Typ Max Units
Operating Case Temperature 0 +50
0
C
Storage Temperature -40 +85
0
C
Relative Humidity w/o
condensation
95 %
Altitude -400 30,000 feet
Shock & Vibration Airborne
Mechanical Specifications
Parameter Value Units Limit
s
Dimensions 8.0 L x 2.25 W x .75 H Inch Max
Weight 14 oz. Max
RF Connectors SMA Female
DC Connectors incl. RFI
filters
4 Wire, 22 AWG
Cooling External Heatsink
Protections
Parameter Value Limits
Load VSWR @ 20 watt Infinite @ all phase
& amplitude for 10
seconds
Nom
The amplifier is adjusted for maximum gain across the operational band at 7.5W output. It is driven
through an external 6 dB pad to add stability. Once the gain has been tested and set, the driving source,
the Symbol Technologies Inc. AR400 output is set to a level, which results in less then the FCC limit of
30 Watts ERP field strength from the antenna at the frequency of highest gain from the amplifier.