DS6708 Digital Scanner Product Reference Guide
DS6708 Digital Scanner Product Reference Guide 72E-86039-01 Revision A October 2006
DS6708 Digital Scanner Product Reference Guide © 2006 by Symbol Technologies, Inc. All rights reserved. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. The software is provided strictly on an “as is” basis.
Revision History Changes to the original manual are listed below: Change -01 Rev A Date 10/2006 Description Initial Release.
DS6708 Digital Scanner Product Reference Guide
Table of Contents Revision History ............................................................................................................. iii About This Guide Introduction ................................................................................................................... Configurations ............................................................................................................... Chapter Descriptions....................................................................
ii DS6708 Digital Scanner Product Reference Guide Chapter 3: Maintenance & Technical Specifications Introduction ................................................................................................................... 3-1 Maintenance ................................................................................................................. 3-1 Troubleshooting ............................................................................................................
Table of Contents Chapter 6: USB Interface Introduction .................................................................................................................. Connecting a USB Interface ......................................................................................... USB Parameter Defaults .............................................................................................. USB Host Parameters .....................................................................................
iv DS6708 Digital Scanner Product Reference Guide Chapter 9: Wand Emulation Interface Introduction ................................................................................................................... 9-1 Connecting Using Wand Emulation .............................................................................. 9-2 Wand Emulation Parameter Defaults ............................................................................ 9-3 Wand Emulation Host Parameters ..............................
Table of Contents Chapter 12: 123Scan Introduction .................................................................................................................. 12-1 123Scan Parameter ..................................................................................................... 12-2 Chapter 13: Symbologies Introduction .................................................................................................................. Scanning Sequence Examples ...................................
vi DS6708 Digital Scanner Product Reference Guide Enable/Disable Code 93 ......................................................................................... 13-27 Set Lengths for Code 93 ......................................................................................... 13-27 Code 11 ........................................................................................................................ 13-29 Code 11 ..............................................................................
Table of Contents Enable/Disable PDF417 ......................................................................................... Enable/Disable MicroPDF417 ................................................................................ Code 128 Emulation ............................................................................................... Data Matrix ............................................................................................................. Maxicode ...........................
viii DS6708 Digital Scanner Product Reference Guide Send Pause ....................................................................................................... 14-27 Skip Ahead ........................................................................................................ 14-28 Skip Back ......................................................................................................... 14-29 Send Preset Value ...........................................................................
Table of Contents Appendix D: Numeric Bar Codes Numeric Bar Codes ...................................................................................................... D-1 Cancel ..........................................................................................................................
x DS6708 Digital Scanner Product Reference Guide
About This Guide About This Guide Introduction The DS6708 Digital Scanner Product Reference Guide provides general instructions for setting up, operating, maintaining and troubleshooting the DS6708 digital scanner. NOTE The DS6708 premier digital decoder does not support imaging. For imaging features and parameters, refer to the DS6707 Digital Imager Scanner Product Reference Guide, p/n 72E-83978-xx. Configurations This guide covers all operating features of the DS6708 Standard Range digital scanner.
xii DS6708 Digital Scanner Product Reference Guide • Chapter 9, Wand Emulation Interface describes how to set up the digital scanner with a Wand Emulation host when Wand Emulation communication is needed. • Chapter 10, Keyboard Wedge Interface describes how to set up a Keyboard Wedge interface with the digital scanner. • Chapter 11, Scanner Emulation Interface describes how to set up the digital scanner with an Undecoded Scanner Emulation host.
About This Guide • xiii Throughout the programming bar code menus, asterisks (*) are used to denote default parameter settings. * Indicates Default *Baud Rate 9600 Feature/Option Related Documents The DS6708 Quick Start Guide, p/n 72-83973-xx, provides general information for getting started with the DS6708 digital scanner, and includes basic set up and operation instructions. For the latest version of this guide and all Symbol guides, go to: http://www.symbol.com/manuals.
xiv DS6708 Digital Scanner Product Reference Guide Symbol Global Interaction Center For service information, warranty information or technical assistance contact or call the Symbol Global Interaction Center in your region. For the most up-to-date contact information, visit: http://www.symbol.com/contactsupport. Country/Region Address Telephone United States Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 1-800-653-5350 Canada Symbol Technologies Canada, Inc.
About This Guide Country/Region Address Telephone Deutschland/ Germany Symbol Technologies GmbH Waldstrasse 66 D-63128 Dietzenbach, Germany 6074-49020 (Inside Germany) +49-6074-49020 (Outside Germany) Italia/Italy Symbol Technologies Italia S.R.L. Via Cristoforo Columbo, 49 20090 Trezzano S/N Navigilo Milano, Italy 2-484441 (Inside Italy) +39-02-484441 (Outside Italy) Latin America Sales Support 2730 University Dr.
xvi DS6708 Digital Scanner Product Reference Guide Country/Region Address Telephone South Africa Symbol Technologies Africa Inc. Block B2 Rutherford Estate 1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11-809 5311 (Inside South Africa) +27-11-809 5311 (Outside South Africa) España/Spain Symbol Technologies S.L. Avenida de Bruselas, 22 Edificio Sauce Alcobendas, Madrid 28108 Spain 91 324 40 00 (Inside Spain) +34 91 324 40 00 (Outside Spain) Fax: +34.91.324.
Chapter 1 Getting Started Chapter 1 Getting Started Introduction The DS6708 Digital Scanner combines superior 1D and 2D omnidirectional bar code scanning and sub-second image capture and transfer to provide the best value in a digital scanner. Whether in hand-held mode or hands-free mode in a stand, the digital scanner ensures comfort and ease of use for extended periods of time.
1-2 DS6708 Digital Scanner Product Reference Guide Supported Interfaces The DS 6708 digital scanner supports: • Keyboard Wedge connection to a host. The host interprets scanned data as keystrokes. This interface supports the following international keyboards (for Windows® environment): North America, German, French, French Canadian, Spanish, Italian, Swedish, UK English, Portuguese-Brazilian, and Japanese. • Standard RS-232 connection to a host.
Getting Started 1-3 Setting Up the Digital Scanner Installing the Interface Cable 1. Plug the interface cable modular connector into the cable interface port on the bottom of the scanner handle. (See Figure 1-2.) 2. Gently tug the cable to ensure the connector is properly secured. 3. Connect the other end of the interface cable to the host (see the specific host chapter for information on host connections).
1-4 DS6708 Digital Scanner Product Reference Guide Connecting a Synapse Cable Interface (DS6708 0nly) NOTE Refer to the Synapse Interface Guide provided with the Synapse cable for detailed setup instructions. Symbol’s Synapse Smart Cables enable interfacing to a variety of hosts. The Synapse cable has built-in intelligence to detect that host. To host Synapse Adapter Cable Synapse Smart Cable To digital scanner Figure 1-4 Synapse Cable Connection 1.
Getting Started 1-5 Mounting the Digital Scanner Desk Mount Use the optional desk mount for convenient and protective placement of the digital scanner on a flat surface. Simply place the mount on the surface. The rubber feet hold the mount securely in place when inserting and removing the digital scanner.
1-6 DS6708 Digital Scanner Product Reference Guide For convenience, print this page and use the template below for mounting hole locations. Insert mounting screw Insert mounting screw 2.
Scanning Chapter 2 Chapter 2 Scanning Introduction This chapter provides beeper and LED definitions, techniques involved in scanning bar codes, general instructions and tips about scanning, and decode zone diagrams.
2-2 DS6708 Digital Scanner Product Reference Guide Beeper Definitions The digital scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines beep sequences that occur during both normal scanning and while programming the digital scanner. Table 2-1 Beeper Definitions Beeper Sequence Indication Standard Use Low/medium/high beeps Power up. Short high beep A bar code symbol was decoded (if decode beeper is enabled).
Scanning 2-3 Table 2-1 Beeper Definitions (Continued) Beeper Sequence Indication Fast warble beep Aborting MPDF sequence. Low/high beeps Flushing an already empty MPDF buffer. ADF Programming: Normal Data Entry. Duration of tones are short. High/low beeps Enter another digit. Add leading zeros to the front if necessary. Low/low beeps Enter another alphabetic character or scan the End of Message bar code. High/high beeps Enter another criterion or action, or scan the Save Rule bar code.
2-4 DS6708 Digital Scanner Product Reference Guide LED Definitions In addition to beep sequences, the digital scanner uses a two-color LED to indicate status. Table 2-2 defines LED colors that display during scanning. Table 2-2 Standard LED Definitions LED Indication Off No power is applied to the digital scanner, or the digital scanner is on and ready to scan. Green A bar code was successfully decoded. Red A data transmission error or digital scanner malfunction occurred.
Scanning 4. 2-5 Center the symbol in any orientation within the aiming pattern. Be sure the entire symbol is within the rectangular area formed by the brackets in the pattern. 2D barsymbol code PDF417 1D bar Linear barcode code Symbol Aiming Pattern Figure 2-11 Centering Symbol in Aiming Pattern 5. Hold the trigger until the digital scanner beeps, indicating the bar code is successfully decoded. For more information on beeper and LED definitions, see Table 2-1 and Table 2-2.
2-6 DS6708 Digital Scanner Product Reference Guide Scanning in Hands-Free Mode The optional Intellistand adds greater flexibility to scanning operation. When the digital scanner is seated in the stand’s “cup,” the digital scanner’s built-in sensor places the digital scanner in hands-free mode. When the digital scanner is removed from the stand it operates in its normal hand-held mode.
Scanning Decode Zones Note: Typical performance at 68˚F (20˚C) on high quality symbols. In. cm 6 15.2 4 10.1 2 5.1 0 0 2 5.1 4 10.1 6 15.2 Top of scanner 5 mil Code 39 2.8 5.8 Postnet 2.6 12.5 100% 13 mil UPC 0.6 1.0 In. cm 0 0 14.0 20 mil Code 39 4 10.1 2 5.1 6 8 15.2 20.3 21.0 10 12 14 25.4 30.5 35.6 16 40.6 18 45.7 22 20 50.8 55.
2-8 DS6708 Digital Scanner Product Reference Guide
Chapter 3 Maintenance & Technical Specifications Chapter 3 Maintenance & Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts). Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy. • Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth.
3-2 DS6708 Digital Scanner Product Reference Guide Troubleshooting Table 3-1 Troubleshooting Problem The aiming pattern does not appear when pressing the trigger. Possible Causes Possible Solutions No power to the digital scanner. If the configuration requires a power supply, re-connect the power supply. Incorrect host interface cable is used. Connect the correct host interface cable. Interface/power cables are loose. Re-connect cables. Digital scanner is disabled.
Maintenance & Technical Specifications 3-3 Table 3-1 Troubleshooting (Continued) Problem Possible Causes Digital scanner decodes bar code, but Digital scanner is not programmed for does not transmit the data to the host. the correct host type. Host displays scanned data incorrectly. Possible Solutions Scan the appropriate host type programming bar code. See the chapter corresponding to the host type. Interface cable is loose. Re-connect the cable.
3-4 DS6708 Digital Scanner Product Reference Guide Table 3-1 Troubleshooting (Continued) Problem Possible Causes Possible Solutions Digital scanner emits low/high/low beeps. Clearing Code 39 buffer. Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer. Digital scanner emits a power-up beep after changing USB host type. The USB bus re-established power to the digital scanner. Normal when changing USB host type.
Maintenance & Technical Specifications 3-5 Table 3-2 Technical Specifications (Continued) Item Description Postal U.S. Postnet and Planet, U.K., Japan, Australian, and Dutch 2-D MaxiCode, DataMatrix (ECC 200), and QR Code Nominal Working Distance (SR - Standard Range focus) 5 mil (Code 39): 1.1 - 6.5 in. (2.8 - 16.5 cm) 13 mil (100% UPC/EAN):0.5 - 9.7 in. (1.3 - 24.6 cm) 20 mil (Code 39): 0.5 - 15.2 in. (1.3 - 38.6 cm) PDF417 (10 Mil): 0.9 - 7 in. (2.3 - 17.8 cm) Datamatrix (10 Mil): 1.1 - 7.5 in.
3-6 DS6708 Digital Scanner Product Reference Guide Digital Scanner Signal Descriptions Bottom of digital scanner Cable interface port Pin 1 Pin 10 Interface cable modular connector Figure 3-1 Digital Scanner Cable Pinouts The signal descriptions in Table 3-3 applies to the connectors on the DS6708 digital scanner and are for reference only.
Chapter 4 User Preferences & Miscellaneous Digital Scanner Options Chapter 4 User Preferences & Miscellaneous Digital Scanner Options Introduction If desired, program the digital scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides the programming bar codes necessary for selecting these features.
4-2 DS6708 Digital Scanner Product Reference Guide Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-5. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning several bar codes.
User Preferences & Miscellaneous Digital Scanner Options Table 4-4 User Preferences Parameter Defaults (Continued) Parameter Beep After Good Decode Paramete r Number Default Page Number 38h Enable 4-11 Transmit Code ID Character 2Dh None 4-12 Prefix Value 63h, 69h 7013 4-13 Suffix 1 Value Suffix 2 Value 62h, 68h 64h, 6Ah 7013 4-13 Scan Data Transmission Format EBh Data as is 4-14 FN1 Substitution Values 67h, 6Dh Set 4-15 Transmit “No Read” Message 5Eh Disabl
4-4 DS6708 Digital Scanner Product Reference Guide User Preferences Set Default Parameter Scan this bar code to return all parameters to the default values listed in Table A-1 on page A-1. *Set All Defaults Parameter Scanning Parameter # ECh To disable decoding of parameter bar codes, scan the Disable Parameter Scanning bar code below. Note that the Set Defaults parameter bar code can still be decoded. To enable decoding of parameter bar codes, either scan Enable Parameter Scanning or Set All Defaults.
User Preferences & Miscellaneous Digital Scanner Options Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code.
4-6 DS6708 Digital Scanner Product Reference Guide Beeper Volume Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code. Low Volume (02h) Medium Volume (01h) *High Volume (00h) Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In reduced power mode, the digital scanner enters into a low power consumption mode to preserve battery life after each decode attempt.
User Preferences & Miscellaneous Digital Scanner Options 4-7 Time Delay to Low Power Mode Parameter # 92h NOTE This parameter only applies when Power Mode is set to Reduced Power. This parameter sets the time the digital scanner remains active after decoding. The digital scanner wakes upon trigger pull or when the host attempts to communicate with the digital scanner.
4-8 DS6708 Digital Scanner Product Reference Guide Time Delay to Low Power Mode (continued) 15 Minutes (2Bh) 1 Hour (31h) Trigger Mode Parameter # 8Ah Select one of the following trigger modes for the digital scanner: • Level - A trigger pull activates decode processing. Decode processing continues until the bar code is decoded, the trigger is released, or the Decode Session Timeout is reached. • Blink - This trigger mode is used in hands-free (Intellistand) mode.
User Preferences & Miscellaneous Digital Scanner Options 4-9 Trigger Mode (continued) *Auto Aim (09h) Picklist Mode Parameter # F0h 92h Picklist mode enables the digital scanner to decode only bar codes that are aligned under the laser crosshair. Select one of the following picklist modes for the digital scanner: • Disabled Always - Picklist mode is always disabled.
4 - 10 DS6708 Digital Scanner Product Reference Guide Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Single digit numbers must have a leading zero.
User Preferences & Miscellaneous Digital Scanner Options 4 - 11 Beep After Good Decode Parameter # 38h Scan a bar code below to select whether or not the digital scanner beeps after a good decode. If selecting Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and to indicate error conditions.
4 - 12 DS6708 Digital Scanner Product Reference Guide Miscellaneous Scanner Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when the digital scanner is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character.
User Preferences & Miscellaneous Digital Scanner Options 4 - 13 Prefix/Suffix Values Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E-1 for the four-digit codes.
4 - 14 DS6708 Digital Scanner Product Reference Guide Scan Data Transmission Format Parameter # EBh To change the scan data format, scan one of the following eight bar codes corresponding to the desired format. NOTE If using this parameter do not use ADF rules to set the prefix/suffix. To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 4-13.
User Preferences & Miscellaneous Digital Scanner Options 4 - 15 Scan Data Transmission Format (continued) (05h) (06h) (07h) FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key).
4 - 16 DS6708 Digital Scanner Product Reference Guide Transmit “No Read” Message Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.
User Preferences & Miscellaneous Digital Scanner Options 4 - 17 Synapse Interface (continued) Auxiliary Synapse Port Connection (32h) “Plug and Play” Synapse Connection (0Ah)
4 - 18 DS6708 Digital Scanner Product Reference Guide
Decoding Preferences Chapter 5 Chapter 5 Decoding Preferences Introduction If desired, program the digital scanner to perform various functions, or activate different features. This chapter describes decoding preference features and provides the programming bar codes for selecting these features. The digital scanner ships with the settings shown in the Decoding Preferences Parameter Defaults on page 5-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults).
5-2 DS6708 Digital Scanner Product Reference Guide Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter. Decoding Preferences Parameter Defaults Table 5-5 lists the defaults for decoding preferences parameters. There are two ways to change the default values: • Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory.
Decoding Preferences 5-3 Decoding Preferences The parameters in this chapter control bar code decoding characteristics. Decoding Illumination Parameter # F0h, 2Ah Selecting Enable Decoding Illumination causes the digital scanner to flash illumination to aid decoding. Select Disable Decoding Illumination to prevent the digital scanner from using decoding illumination. Enabling illumination usually results in superior images.
5-4 DS6708 Digital Scanner Product Reference Guide Illumination Bank Control Parameter # F1h 3Bh Selecting an illumination bank control parameter allows the user to control the illumination banks on the scan engine. • Full (0) (default): The full illumination system is enabled. • Auto (1): The illumination system automatically switches from left to right banks. • Left • Right (3): The right bank is enabled. (2): The left bank is enabled.
Decoding Preferences 5-5 Decode Aiming Pattern Parameter # F0h, 32h This parameter only applies when in Decode Mode. Select Enable Decode Aiming Pattern to project the aiming pattern during bar code capture, or Disable Decode Aiming Pattern to turn the aiming pattern off. NOTE With picklist enabled, the decode aiming pattern flashes even when the Decode Aiming Pattern is disabled.
5-6 DS6708 Digital Scanner Product Reference Guide
USB Interface Chapter 6 Chapter 6 USB Interface Introduction This chapter describes how to set up the digital scanner with a USB host. The digital scanner connects directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. Throughout the programming bar code menus, default values are indicated with asterisks (*).
6-2 DS6708 Digital Scanner Product Reference Guide Connecting a USB Interface USB Series A Connector Interface Cable Figure 6-1 USB Connection The digital scanner connects with USB-capable hosts including: Desktop PCs and notebooks • - Apple™ iMac, G4, iBooks (North America only) - IBM SurePOS terminals Sun, IBM, and other network computers that support more than one keyboard. • The following operating systems support the digital scanner through USB: • • • Windows® 98, 2000, ME, XP MacOS 8.
USB Interface 6-3 4. On first installation when using Windows, the software prompts to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The digital scanner powers up during this installation. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter. If problems occur with the system, see Troubleshooting on page 3-2.
6-4 DS6708 Digital Scanner Product Reference Guide USB Host Parameters USB Device Type Select the desired USB device type. NOTE When changing USB Device Types, the digital scanner automatically resets. The digital scanner issues the standard startup beep sequences.
USB Interface 6-5 USB Country Keyboard Types - Country Codes Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. NOTE When changing USB country keyboard types the digital scanner automatically resets. The digital scanner issues the standard startup beep sequences.
6-6 DS6708 Digital Scanner Product Reference Guide USB Country Keyboard Types - Country Codes (continued) Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows (ASCII) Portuguese-Brazilian Windows
USB Interface USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data. *No Delay Medium Delay (20 msec) Long Delay (40 msec) USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device. When enabled, the case of the data is preserved regardless of the state of the Caps Lock key.
6-8 DS6708 Digital Scanner Product Reference Guide USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound.
USB Interface 6-9 Emulate Keypad with Leading Zero When enabled, character sequences sent over the numeric keypad are sent as ISO characters which have a leading zero. For example ASCII A would be sent as “ALT MAKE” 0 0 6 5 “ALT BREAK”. *Disable Keypad Emulation with Leading Zero Enable Keypad Emulation with Leading Zero USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device.
6 - 10 DS6708 Digital Scanner Product Reference Guide Function Key Mapping ASCII values under 32 are normally sent as a control-key sequences (see Table 6-2 on page 6-12). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not this parameter is enabled.
USB Interface 6 - 11 Convert Case When enabled, the digital scanner converts all bar code data to the selected case.
6 - 12 DS6708 Digital Scanner Product Reference Guide ASCII Character Set for USB Table 6-2 USB Prefix/Suffix Values Prefix/ Suffix Value Full ASCII Code 39 Encode Char.
USB Interface 6 - 13 Table 6-2 USB Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Char.acter Prefix/ Suffix Value Keystroke 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [/ESC1 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
6 - 14 DS6708 Digital Scanner Product Reference Guide Table 6-2 USB Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Char.
USB Interface 6 - 15 Table 6-2 USB Prefix/Suffix Values (Continued) Prefix/ Suffix Value Full ASCII Code 39 Encode Char.
6 - 16 DS6708 Digital Scanner Product Reference Guide Table 6-2 USB Prefix/Suffix Values (Continued) Prefix/ Suffix Value Full ASCII Code 39 Encode Char.acter Keystroke 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1 The keystroke in bold is sent only if the “Function Key Mapping” is enabled.
USB Interface 6 - 17 Table 6-3 USB ALT Key Character Set ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z
6 - 18 DS6708 Digital Scanner Product Reference Guide Table 6-4 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O Note: GUI Shift Keys - The Apple™ iMac keyboard has
USB Interface 6 - 19 Table 6-4 USB GUI Key Character Set (Continued) GUI Key Keystroke 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windows-based systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key.
6 - 20 DS6708 Digital Scanner Product Reference Guide Table 6-5 USB F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24
USB Interface 6 - 21 Table 6-6 USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 .
6 - 22 DS6708 Digital Scanner Product Reference Guide Table 6-7 USB Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow
RS-232 Interface Chapter 7 Chapter 7 RS-232 Interface Introduction This chapter describes how to set up the digital scanner with an RS-232 host. The RS-232 interface is used to connect the digital scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If the host is not listed in Table 7-2, refer to the documentation for the host device to set communication parameters to match the host.
7-2 DS6708 Digital Scanner Product Reference Guide Connecting an RS-232 Interface This connection is made directly from the digital scanner to the host computer. Interface Cable Serial Port Connector to Host Power Supply Cable Figure 7-1 RS-232 Direct Connection NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 7-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same. 1.
RS-232 Interface 7-3 RS-232 Parameter Defaults Table 7-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the RS-232 Host Parameters section beginning on page 7-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
7-4 DS6708 Digital Scanner Product Reference Guide RS-232 Host Parameters Various RS-232 hosts are set up with their own parameter default settings (Table 7-2). Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed below.
RS-232 Interface 7-5 RS-232 Host Parameters (continued) Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of code ID characters listed in Table 7-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.
7-6 DS6708 Digital Scanner Product Reference Guide RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes. Standard RS-2321 ICL RS-232 Wincor-Nixdorf RS-232 Mode A Wincor-Nixdorf RS-232 Mode B Olivetti ORS4500 Omron 1Scanning Enable RS-232 (No Variant) activates the RS-232 driver, but does not change port settings (e.g., parity, data bits, handshaking). Selecting another RS-232 host type bar code changes these settings.
RS-232 Interface 7-7 RS-232 Host Types (continued) OPOS/JPOS Fujitsu RS-232 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the digital scanner's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.
7-8 DS6708 Digital Scanner Product Reference Guide Baud Rate (continued) *Baud Rate 9600 Baud Rate 19,200 Baud Rate 38,400 Baud Rate 57,600 Baud Rate 115,200
RS-232 Interface 7-9 Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. • Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.
7 - 10 DS6708 Digital Scanner Product Reference Guide Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
RS-232 Interface 7 - 11 Check Receive Errors Select whether or not the parity, framing, and overrun of received characters are checked. The parity value of received characters is verified against the parity parameter selected above. *Check For Received Errors Do Not Check For Received Errors Hardware Handshaking The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS).
7 - 12 DS6708 Digital Scanner Product Reference Guide Hardware Handshaking (continued) • None: Scan the bar code below if no Hardware Handshaking is desired. • Standard RTS/CTS: Scan the bar code below to select Standard RTS/CTS Hardware Handshaking. • RTS/CTS Option 1: When RTS/CTS Option 1 is selected, the digital scanner asserts RTS before transmitting and ignores the state of CTS. The digital scanner de-asserts RTS when the transmission is complete.
RS-232 Interface 7 - 13 Hardware Handshaking (continued) RTS/CTS Option 2 RTS/CTS Option 3 Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence. • None: When this option is selected, data is transmitted immediately. No response is expected from host.
7 - 14 DS6708 Digital Scanner Product Reference Guide Software Handshaking (continued) - XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the digital scanner receives an XON character, it sends the rest of the data message. The digital scanner waits indefinitely for the XON.
RS-232 Interface 7 - 15 Host Serial Response Time-out This parameter specifies how long the digital scanner waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option. *Minimum: 2 Sec Low: 2.5 Sec Medium: 5 Sec High: 7.5 Sec Maximum: 9.
7 - 16 DS6708 Digital Scanner Product Reference Guide RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state. *Host: Low RTS Host: High RTS Beep on When this parameter is enabled, the digital scanner issues a beep when a character is detected on the RS-232 serial line. is issued to gain a user's attention to an illegal entry or other important event.
RS-232 Interface 7 - 17 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions.
7 - 18 DS6708 Digital Scanner Product Reference Guide Nixdorf Beep/LED Options When Nixdorf Mode B is selected, this indicates when the digital scanner should beep and turn on its LED after a decode. *Normal Operation (Beep/LED immediately after decode) Beep/LED After Transmission Beep/LED After CTS Pulse Ignore Unknown Characters Unknown characters are characters the host does not recognize.
RS-232 Interface 7 - 19 ASCII Character Set for RS-232 The values in Table 7-4 can be assigned as prefixes or suffixes for ASCII character data transmission.
7 - 20 DS6708 Digital Scanner Product Reference Guide Table 7-4 Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Character Prefix/Suffix Value ASCII Character 1026 $Z SUB 1027 %A ESC 1028 %B FS 1029 %C GS 1030 %D RS 1031 %E US 1032 Space Space 1033 /A ! 1034 /B " 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
RS-232 Interface 7 - 21 Table 7-4 Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Character Prefix/Suffix Value ASCII Character 1055 7 7 1056 8 8 1057 9 9 1058 /Z : 1059 %F ; 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S
7 - 22 DS6708 Digital Scanner Product Reference Guide Table 7-4 Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Character Prefix/Suffix Value ASCII Character 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ` 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 1110 +N
RS-232 Interface 7 - 23 Table 7-4 Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Character Prefix/Suffix Value ASCII Character 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1127 Undefined 7013 ENTER
7 - 24 DS6708 Digital Scanner Product Reference Guide
IBM 468X / 469X Interface Chapter 8 Chapter 8 IBM 468X / 469X Interface Introduction This chapter describes how to set up the digital scanner with an IBM 468X/469X host. Throughout the programming bar code menus, default values are indicated with asterisks (*). * Indicates Default *Disable Convert to Code 39 Feature/Option NOTE Most computer monitors allow scanning the bar codes directly on the screen.
8-2 DS6708 Digital Scanner Product Reference Guide Connecting to an IBM 468X/469X Host This connection is made directly from the digital scanner to the host interface. Interface Cable Host Port Connector Figure 8-2 IBM Direct Connection NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 8-2 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same. 1.
IBM 468X / 469X Interface 8-3 IBM Parameter Defaults Table 8-5 lists the defaults for IBM host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 8-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
8-4 DS6708 Digital Scanner Product Reference Guide IBM 468X/469X Host Parameters Port Address This parameter sets the IBM 468X/469X port used. NOTE Scanning one of these bar codes enables the RS-485 interface on the digital scanner.
IBM 468X / 469X Interface Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39.
8-6 DS6708 Digital Scanner Product Reference Guide
Wand Emulation Interface Chapter 9 Chapter 9 Wand Emulation Interface Introduction This chapter describes how to set up the digital scanner with a wand emulation host when Wand Emulation communication is needed. The digital scanner connects to an external wand decoder or to a decoder integrated in a mobile computer or Point-of-Sale (POS) terminal. In this mode the digital scanner emulates the signal of a digital wand to make it "readable" by a wand decoder.
9-2 DS6708 Digital Scanner Product Reference Guide Connecting Using Wand Emulation To perform Wand Emulation, connect the digital scanner to a mobile computer, or a controller which collects the wand data and interprets it for the host. Mobile Computer Wand Port Interface Cable Figure 9-3 Wand Emulation Connection NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 9-3 are examples only.
Wand Emulation Interface 9-3 Wand Emulation Parameter Defaults Table 9-6 lists the defaults for Wand Emulation host types. To change any option, scan the appropriate bar code(s) provided in Wand Emulation Host Parameters on page 9-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
9-4 DS6708 Digital Scanner Product Reference Guide Wand Emulation Host Parameters Wand Emulation Host Types Select a Wand Emulation host by scanning one of the bar codes below.
Wand Emulation Interface 9-5 Leading Margin (Quiet Zone) Scan a bar code below to select a leading margin duration. A leading margin is the time that precedes the first bar of the scan, (in milliseconds). The minimum allowed value is 80 msec and the maximum is 250 msec. This parameter accommodates older wand decoders which cannot handle short leading margins. NOTE 250 msec is the maximum value that this parameter can attain, however, 200 msec is sufficient.
9-6 DS6708 Digital Scanner Product Reference Guide Polarity Polarity determines how the digital scanner's Wand Emulation interface creates the Digitized Barcode Pattern (DBP). DBP is a digital signal that represents the scanned bar code. Different decoders expect the DBP to be in a certain format. The DBP either has the "highs" represent bars and the "lows" represent spaces (margins), or the "highs" represent spaces (margins) and the "lows" represent bars.
Wand Emulation Interface 9-7 Convert All Bar Codes to Code 39 By default, the Wand Emulation interface sends data to the attached host in the same symbology that was decoded. This can be a problem for customers with older systems that do not recognize newer symbologies (for example, RSS). Enabling this parameter ignores the original symbology decoded, and outputs the data as if it were a Code 39 bar code. Any lowercase characters in the original data stream are transmitted as uppercase characters.
9-8 DS6708 Digital Scanner Product Reference Guide Convert Code 39 to Full ASCII By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the wand Interface is encoded in Code 39 Full ASCII. This setting requires that the Host be able to interpret Code 39 Full ASCII data. This setting applies only if Convert to Code 39 is also enabled.
Keyboard Wedge Interface Chapter 10 Chapter 10 Keyboard Wedge Interface Introduction This chapter describes how to set up a Keyboard Wedge interface with the digital scanner. With this interface, the digital scanner is connected between the keyboard and host computer, and translates bar code data into keystrokes. The host computer accepts the keystrokes as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input.
10 - 2 DS6708 Digital Scanner Product Reference Guide Connecting a Keyboard Wedge Interface Male DIN Female DIN Keyboard Connector Figure 10-1. Keyboard Wedge Connection with Y-cable To connect the Keyboard Wedge interface Y-cable: NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 10-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same 1. .
Keyboard Wedge Interface 10 - 3 Keyboard Wedge Parameter Defaults Table 10-7 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section beginning on page 10-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
10 - 4 DS6708 Digital Scanner Product Reference Guide Keyboard Wedge Host Parameters Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below.
Keyboard Wedge Interface 10 - 5 Keyboard Wedge Country Types - Country Codes Scan the bar code corresponding to the keyboard type. If the keyboard type is not listed, see Alternate Numeric Keypad Emulation on page 10-8.
10 - 6 DS6708 Digital Scanner Product Reference Guide Keyboard Wedge Country Types - Country Codes (continued) Italian Windows Swedish Windows UK English Windows Japanese Windows Portuguese-Brazilian Windows
Keyboard Wedge Interface 10 - 7 Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the digital scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character, then the digital scanner issues an error beep.
10 - 8 DS6708 Digital Scanner Product Reference Guide Intra-Keystroke Delay When enabled, an additional delay is inserted between each emulated key depression and release. This sets the Keystroke Delay parameter to a minimum of 5 msec as well. Enable *Disable Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types Country Codes on page 10-5 in a Microsoft® operating system environment.
Keyboard Wedge Interface 10 - 9 Caps Lock On When enabled, the digital scanner emulates keystrokes as if the Caps Lock key is always pressed. Enable Caps Lock On *Disable Caps Lock On Caps Lock Override When enabled, on AT or AT Notebook hosts, the keyboard ignores the state of the Caps Lock key. Therefore, an ‘A’ in the bar code is sent as an ‘A’ no matter what the state of the keyboard’s Caps Lock key.
10 - 10 DS6708 Digital Scanner Product Reference Guide Convert Wedge Data When enabled, the digital scanner converts all bar code data to the selected case. Convert to Upper Case Convert to Lower Case *No Convert Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table 10-8 on page 10-14). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping.
Keyboard Wedge Interface 10 - 11 FN1 Substitution When this is enabled, the digital scanner replaces FN1 characters in an EAN128 bar code with a keystroke chosen by the user (see FN1 Substitution on page 10-11). Enable *Disable Send Make and Break When enabled, the scan codes for releasing a key are not sent.
10 - 12 DS6708 Digital Scanner Product Reference Guide Keyboard Maps The following keyboard maps are provided for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 4-13.
Keyboard Wedge Interface 10 - 13 5001 5002 1045 5013 5003 5004 5014 5015 5005 5006 1043 5016 5007 5008 5017 5018 5009 5010 7013 5019 5011 1048 5012 1046 (1048 if double key) (7013 if double key) Figure 10-7 NCR 7052 32-Key 1065 1066 1067 1068 1072 1073 1074 1079 1080 1081 5001 5002 5011 5003 1069 1070 1071 1075 1076 1077 1078 1082 1083 1084 1085 1045 5013 1086 5004 5014 5015 1087 5005 5006 1043 5016 1088 5007 5008 5017 5018 1089 5009 501
10 - 14 DS6708 Digital Scanner Product Reference Guide ASCII Character Set for Keyboard Wedge NOTE Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and +B is scanned, it is interpreted as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >.
Keyboard Wedge Interface 10 - 15 Table 10-8 Keyboard Wedge ASCII Character Set (Continued) Full ASCII Code 39 Encode Char.
10 - 16 DS6708 Digital Scanner Product Reference Guide Table 10-8 Keyboard Wedge ASCII Character Set (Continued) Full ASCII Code 39 Encode Char.
Keyboard Wedge Interface 10 - 17 Table 10-8 Keyboard Wedge ASCII Character Set (Continued) ASCII Value Full ASCII Code 39 Encode Char.
10 - 18 DS6708 Digital Scanner Product Reference Guide Table 10-8 Keyboard Wedge ASCII Character Set (Continued) ASCII Value Full ASCII Code 39 Encode Char.
Keyboard Wedge Interface 10 - 19 Table 10-9 Keyboard Wedge ALT Key Character Set ALT Keys Keystroke 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z
10 - 20 DS6708 Digital Scanner Product Reference Guide Table 10-10 Keyboard Wedge GUI Key Character Set GUI Keys Keystrokes 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q 3082 GUI
Keyboard Wedge Interface 10 - 21 Table 10-10 Keyboard Wedge GUI Key Character Set (Continued) GUI Keys Keystrokes 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table 10-11 Keyboard Wedge F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20
10 - 22 DS6708 Digital Scanner Product Reference Guide Table 10-11 Keyboard Wedge F Key Character Set (Continued) F Keys Keystroke 5021 F21 5022 F22 5023 F23 5024 F24 Table 10-12 Keyboard Wedge Numeric Keypad Character Set Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 .
Keyboard Wedge Interface 10 - 23 Table 10-13 Keyboard Wedge Extended Keypad Character Set (Continued) Extended Keypad Keystroke 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow
10 - 24 DS6708 Digital Scanner Product Reference Guide
Scanner Emulation Interface Chapter 11 Chapter 11 Scanner Emulation Interface Introduction This chapter describes how to set up the digital scanner with a Scanner Emulation host. Use this mode when Scanner Emulation communication is needed. In this mode, the digital scanner connects to an external decoder or to a decoder integrated in a mobile computer or Point-of-Sale (POS) terminal. Throughout the programming bar code menus, default values are indicated with asterisks (*).
11 - 2 DS6708 Digital Scanner Product Reference Guide Connecting Using Scanner Emulation To perform Scanner Emulation, connect the digital scanner to a mobile computer, or a controller which collects the data and interprets it for the host. Host Port Connector Interface Cable Figure 11-1 Scanner Emulation Connection NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 11-1 are examples only.
Scanner Emulation Interface 11 - 3 Scanner Emulation Parameter Defaults Table 11-1 lists the defaults for the Scanner Emulation host. To change any option, scan the appropriate bar code(s) provided in the Scanner Emulation Host Parameters section beginning on page 11-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
11 - 4 DS6708 Digital Scanner Product Reference Guide Scanner Emulation Host Scan the bar code below to enable the Scanner Emulation host. Scanner Emulation Host Scanner Emulation Host Parameters Beep Style The Scanner Emulation host supports three beep styles. • Beep On Successful Transmit: The digital scanner beeps when the attached decoder issues the decode signal to the digital scanner, so the digital scanner and the attached decoder beep at the same time.
Scanner Emulation Interface 11 - 5 Parameter Pass-Through The Scanner Emulation host can process parameter bar code messages and send them to the attached decoder. In this way, customers using Symbol compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once. For example, to enable D 2 of 5, scan the D 2 of 5 Enable parameter bar code. The digital scanner and the attached decoder both process the parameter.
11 - 6 DS6708 Digital Scanner Product Reference Guide Convert Newer Code Types (continued) When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and transmits no data. The amount of data in the scanned newer bar code type should not exceed that of the conversion code type. *Convert Newer Code Types Reject Newer Code Types Module Width The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.
Scanner Emulation Interface 11 - 7 Convert All Bar Codes to Code 39 Scan a bar code below to enable or disable the conversion of all bar code data to Code 39. *Do Not Convert Bar Codes To Code 39 Convert All To Code 39 Code 39 Full ASCII Conversion By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the Scanner Emulation host is encoded in Code 39 Full ASCII.
11 - 8 DS6708 Digital Scanner Product Reference Guide Transmission Timeout The Scanner Emulation host transmits bar code data to the attached decoder and waits for the decoder to assert the Decode signal, indicating successful transmission. If, after a specified amount of time, the Decode signal is not asserted (indicating that the attached decoder has not successfully received the bar code data), the digital scanner issues transmit error beeps.
Scanner Emulation Interface 11 - 9 Ignore Unknown Characters Unknown characters are characters the decoder does not recognize. When Ignore Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Convert Error on Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the decoder, and a convert error beep sounds.
11 - 10 DS6708 Digital Scanner Product Reference Guide Leading Margin (continued) 5 ms Leading Margin 10 ms Leading Margin Check For Decode LED The attached decoder normally asserts the Decode line to signal to the Scanner Emulation host that it successfully decoded the transmitted bar code. Some decoders, however, do not assert the Decode signal. In this case, the digital scanner emits transmit error beeps to indicate that the bar code was not successfully transmitted.
Chapter 12 123Scan Chapter 12 123Scan Introduction 123Scan is a Windows®-based utility that programs the digital scanner with all parameters including Advanced Data Formatting (ADF) Rules. An ADF rule modifies bar code data before it is sent to the host to ensure compatibility between bar coded data and the host application. Digital scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility.
12 - 2 DS6708 Digital Scanner Product Reference Guide 123Scan Parameter To communicate with the 123Scan program, load 123Scan, included in the documentation CD-ROM, onto the host computer, and scan the bar code below. Refer to 123Scan instructions for programming the digital scanner. Scan the bar code below to enable the 123Scan interface on the digital scanner.
Symbologies Chapter 13 Chapter 13 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down.
13 - 2 DS6708 Digital Scanner Product Reference Guide Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter. Symbology Parameter Defaults Table 13-1 lists the defaults for all symbologies parameters. There are two ways to change the default values: • Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory.
Symbologies 13 - 3 Table 13-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Convert UPC-E1 to A 26h Disable 13-16 EAN-8/JAN-8 Extend 27h Disable 13-17 UCC Coupon Extended Code 55h Disable 13-17 Code 128 08h Enable 13-18 UCC/EAN-128 0Eh Enable 13-18 ISBT 128 54h Enable 13-19 Code 39 00h Enable 13-19 Trioptic Code 39 0Dh Disable 13-20 Convert Code 39 to Code 32 (Italian Pharmacy Code) 56h Disable 13-20 Code 32 Prefix E7h Disable 13-21
13 - 4 DS6708 Digital Scanner Product Reference Guide Table 13-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Transmit I 2 of 5 Check Digit 2Ch Disable 13-34 Convert I 2 of 5 to EAN 13 52h Disable 13-35 Discrete 2 of 5 05h Disable 13-35 Set Length(s) for D 2 of 5 14h 15h 12 13-36 Codabar 07h Disable 13-38 Set Lengths for Codabar 18h 19h 5 to 55 13-38 CLSI Editing 36h Disable 13-40 NOTIS Editing 37h Disable 13-40 MSI 0Bh Disable 13-41
Symbologies 13 - 5 Table 13-1 Parameter Defaults (Continued) Parameter Convert RSS to UPC/EAN Parameter Number Default Page Number F0h 8Dh Disable 13-50 Composite CC-C F0h 55h Disable 13-51 Composite CC-A/B F0h 56h Disable 13-51 Composite TLC-39 F0h 73h Disable 13-52 UPC Composite Mode F0h 58h Always Linked 13-52 Composite Beep Mode F0h 8Eh Beep As Each Code Type is Decoded 13-53 UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes F0h ABh Disable 13-53 PDF417 0Fh E
13 - 6 DS6708 Digital Scanner Product Reference Guide UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below. *Enable UPC-A (01h) Disable UPC-A (00h) Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.
Symbologies 13 - 7 Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology. Enable UPC-E1 (01h) *Disable UPC-E1 (00h) Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.
13 - 8 DS6708 Digital Scanner Product Reference Guide Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, scan the appropriate bar code below. *Enable EAN-13/JAN-13 (01h) Disable EAN-13/JAN-13 (00h) Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below.
Symbologies 13 - 9 Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available. • If Decode UPC/EAN/JAN Only With Supplementals is selected, UPC/EAN/JAN symbols without supplementals are not decoded.
13 - 10 DS6708 Digital Scanner Product Reference Guide Decode UPC/EAN/JAN Supplementals (continued) Enable 378/379 Supplemental Mode (04h) Enable 978 Supplemental Mode (05h) Enable Smart Supplemental Mode (03h) UPC/EAN/JAN Supplemental Redundancy Parameter # 50h With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to thirty times.
Symbologies 13 - 11 Transmit UPC-A Check Digit Parameter # 28h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-A check digit. It is always verified to guarantee the integrity of the data.
13 - 12 DS6708 Digital Scanner Product Reference Guide Transmit UPC-E1 Check Digit Parameter # 2Ah The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data.
Symbologies 13 - 13 UPC-A Preamble Parameter # 22h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-A preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
13 - 14 DS6708 Digital Scanner Product Reference Guide UPC-E Preamble Parameter # 23h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
Symbologies 13 - 15 UPC-E1 Preamble Parameter # 24h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
13 - 16 DS6708 Digital Scanner Product Reference Guide Convert UPC-E to UPC-A Parameter # 25h Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). When disabled, UPC-E decoded data is transmitted as UPC-E data, without conversion.
Symbologies 13 - 17 EAN-8/JAN-8 Extend Parameter # 27h When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. When disabled, EAN-8 symbols are transmitted as is. Enable EAN/JAN Zero Extend (01h) *Disable EAN/JAN Zero Extend (00h) UCC Coupon Extended Code Parameter # 55h When enabled, this parameter decodes UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/EAN-128 Coupon Codes.
13 - 18 DS6708 Digital Scanner Product Reference Guide Code 128 Enable/Disable Code 128 Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below. *Enable Code 128 (01h) Disable Code 128 (00h) Enable/Disable UCC/EAN-128 Parameter # 0Eh To enable or disable UCC/EAN-128, scan the appropriate bar code below.
Symbologies 13 - 19 Enable/Disable ISBT 128 Parameter # 54h ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data. *Enable ISBT 128 (01h) Disable ISBT 128 (00h) Code 39 Enable/Disable Code 39 Parameter # 00h To enable or disable Code 39, scan the appropriate bar code below.
13 - 20 DS6708 Digital Scanner Product Reference Guide Enable/Disable Trioptic Code 39 Parameter # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below. Enable Trioptic Code 39 (01h) *Disable Trioptic Code 39 (00h) NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Symbologies 13 - 21 Code 32 Prefix Parameter # E7h Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes. NOTE Convert Code 39 to Code 32 must be enabled for this parameter to function. Enable Code 32 Prefix (01h) *Disable Code 32 Prefix (00h) Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
13 - 22 DS6708 Digital Scanner Product Reference Guide • Length Within Range - Select this option to decode a Code 39 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel on page D-2.
Symbologies 13 - 23 Code 39 Check Digit Verification Parameter # 30h When this feature is enabled, the digital scanner checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.
13 - 24 DS6708 Digital Scanner Product Reference Guide Code 39 Full ASCII Conversion Parameter # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Enable Code 39 Full ASCII (01h) *Disable Code 39 Full ASCII (00h) NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Symbologies 13 - 25 Code 39 Buffering - Scan & Store (continued) This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the digital scanner to decode Code 39 symbology only. Buffer Code 39 (Enable) (01h) *Do Not Buffer Code 39 (Disable) (00h) While there is data in the transmission buffer, selecting Do Not Buffer Code 39 is not allowed. The buffer holds 200 bytes of information.
13 - 26 DS6708 Digital Scanner Product Reference Guide Transmit Buffer There are two methods to transmit the Code 39 buffer. 1. Scan the Transmit Buffer bar code below. Only a start character, a plus (+), and a stop character. 2. The digital scanner transmits and clears the buffer. • The digital scanner issues a low/high beep. Transmit Buffer Scan a Code 39 bar code with a leading character other than a space. 3. • The digital scanner appends new decode data to buffered data.
Symbologies 13 - 27 Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 (01h) *Disable Code 93 (00h) Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range.
13 - 28 DS6708 Digital Scanner Product Reference Guide Set Lengths for Code 93 (continued) Code 93 - One Discrete Length Code 93 - Two Discrete Lengths Code 93 - Length Within Range Code 93 - Any Length
Symbologies 13 - 29 Code 11 Code 11 Parameter # 0Ah To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 (01h) *Disable Code 11 (00h) Set Lengths for Code 11 Parameter # L1 = 1Ch, L2 = 1Dh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range.
13 - 30 DS6708 Digital Scanner Product Reference Guide Set Lengths for Code 11 Code 11 - One Discrete Length Code 11 - Two Discrete Lengths Code 11 - Length Within Range Code 11 - Any Length
Symbologies 13 - 31 Code 11 Check Digit Verification Parameter # 34h This feature allows the digital scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature.
13 - 32 DS6708 Digital Scanner Product Reference Guide Interleaved 2 of 5 (ITF) Enable/Disable Interleaved 2 of 5 Parameter # 06h To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5 length from the following pages. *Enable Interleaved 2 of 5 (01h) Disable Interleaved 2 of 5 (00h) Set Lengths for Interleaved 2 of 5 Parameter # L1 = 16h, L2 = 17h The length of a code refers to the number of characters (i.e.
Symbologies 13 - 33 Set Lengths for Code 11 (continued) NOTE Due to the construction of the I 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (I 2 of 5 - One Discrete Length - Two Discrete Lengths) for I 2 of 5 applications.
13 - 34 DS6708 Digital Scanner Product Reference Guide I 2 of 5 Check Digit Verification Parameter # 31h When this feature is enabled, the digital scanner checks the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.
Symbologies 13 - 35 Convert I 2 of 5 to EAN-13 Parameter # 52h Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13. To accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN-13 check digit.
13 - 36 DS6708 Digital Scanner Product Reference Guide Set Lengths for Discrete 2 of 5 Parameter # L1 = 14h, L2 = 15h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for D 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only D 2 of 5 symbols containing a selected length.
Symbologies 13 - 37 Set Lengths for Discrete 2 of 5 (continued) D 2 of 5 - One Discrete Length D 2 of 5 - Two Discrete Lengths D 2 of 5 - Length Within Range D 2 of 5 - Any Length
13 - 38 DS6708 Digital Scanner Product Reference Guide Codabar (NW - 7) Enable/Disable Codabar Parameter # 07h To enable or disable Codabar, scan the appropriate bar code below. Enable Codabar (01h) *Disable Codabar (00h) Set Lengths for Codabar Parameter # L1 = 18h, L2 = 19h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
Symbologies 13 - 39 Set Lengths for Codabar (continued) • Any Length - Scan this option to decode Codabar symbols containing any number of characters within the digital scanner capability.
13 - 40 DS6708 Digital Scanner Product Reference Guide CLSI Editing Parameter # 36h When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format. NOTE Symbol length does not include start and stop characters.
Symbologies 13 - 41 MSI Enable/Disable MSI Parameter # 0Bh To enable or disable MSI, scan the appropriate bar code below. Enable MSI (01h) *Disable MSI (00h) Set Lengths for MSI Parameter # L1 = 1Eh, L2 = 1Fh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range.
13 - 42 DS6708 Digital Scanner Product Reference Guide Set Lengths for MSI (continued) • Any Length - Scan this option to decode MSI symbols containing any number of characters within the digital scanner capability. NOTE Due to the construction of the MSI symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code.
Symbologies 13 - 43 MSI Check Digits Parameter # 32h With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If the MSI codes include two check digits, scan the Two MSI Check Digits bar code to enable verification of the second check digit. See MSI Check Digit Algorithm on page 13-44 for the selection of second digit algorithms.
13 - 44 DS6708 Digital Scanner Product Reference Guide MSI Check Digit Algorithm Parameter # 33h Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode the check digit. MOD 10/MOD 11 (00h) *MOD 10/MOD 10 (01h) Postal Codes US Postnet Parameter # 59h To enable or disable US Postnet, scan the appropriate bar code below.
Symbologies 13 - 45 US Planet Parameter # 5Ah To enable or disable US Planet, scan the appropriate bar code below. *Enable US Planet (01h) Disable US Planet (00h) UK Postal Parameter # 5Bh To enable or disable UK Postal, scan the appropriate bar code below.
13 - 46 DS6708 Digital Scanner Product Reference Guide Transmit UK Postal Check Digit Parameter # 60h Select whether to transmit UK Postal data with or without the check digit. *Transmit UK Postal Check Digit (01h) Do Not Transmit UK Postal Check Digit (00h) Japan Postal Parameter # F0h, 22h To enable or disable Japan Postal, scan the appropriate bar code below.
Symbologies 13 - 47 Australian Postal Parameter # F0h, 23h To enable or disable Australian Postal, scan the appropriate bar code below. *Enable Australian Postal (01h) Disable Australian Postal (00h) Dutch Postal Parameter # F0h, 46h To enable or disable Dutch Postal, scan the appropriate bar code below.
13 - 48 DS6708 Digital Scanner Product Reference Guide Transmit US Postal Check Digit Parameter # 5Fh Select whether to transmit US Postal data with or without the check digit.
Symbologies 13 - 49 RSS (Reduced Space Symbology) The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and expanded versions have stacked variants. Scan the appropriate bar code below to enable or disable each variant of RSS. RSS-14 Parameter # F0h 52h. *Enable RSS 14 (01h) Disable RSS 14 (00h) RSS Limited Parameter # F0h 53h.
13 - 50 DS6708 Digital Scanner Product Reference Guide RSS Expanded Parameter # F0h 54h. *Enable RSS Expanded (01h) Disable RSS Expanded (00h) Convert RSS to UPC/EAN Parameter # F0h, 8Dh This parameter only applies to RSS-14 and RSS Limited symbols not decoded as part of a Composite symbol. Enable this to strip the leading '010' from RSS-14 and RSS Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13.
Symbologies 13 - 51 Composite Composite CC-C Parameter # F0h 55h Scan a bar code below to enable or disable Composite bar codes of type CC-C. Enable CC-C (01h) *Disable CC-C (00h) Composite CC-A/B Parameter # F0h 56h Scan a bar code below to enable or disable Composite bar codes of type CC-A/B.
13 - 52 DS6708 Digital Scanner Product Reference Guide Composite TLC-39 Parameter # F0h 73h Scan a bar code below to enable or disable Composite bar codes of type TLC-39. Enable TLC39 (01h) *Disable TLC39 (00h) UPC Composite Mode Parameter # F0h 58h UPC symbols can be “linked” with a 2D symbol during transmission as if they were one symbol. There are three options for these symbols: • Select UPC Never Linked to transmit UPC bar codes regardless of whether a 2D symbol is detected.
Symbologies 13 - 53 Composite Beep Mode Parameter # F0h, 8Eh To select the number of decode beeps when a composite bar code is decoded, scan the appropriate bar code. Single Beep after both are decoded (00h) *Beep as each code type is decoded (01h) Double Beep after both are decoded (02h) UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes Parameter # F0h, ABh Select whether to enable or disable this mode.
13 - 54 DS6708 Digital Scanner Product Reference Guide 2D Symbologies Enable/Disable PDF417 Parameter # 0Fh To enable or disable PDF417, scan the appropriate bar code below. *Enable PDF417 (01h) Disable PDF417 (00h) Enable/Disable MicroPDF417 Parameter # E3h To enable or disable MicroPDF417, scan the appropriate bar code below.
Symbologies 13 - 55 Code 128 Emulation Parameter # 7Bh When this parameter is enabled, the scanner transmits data from certain MicroPDF417 symbols as if it was encoded in Code 128 symbols. Transmit AIM Symbology Identifiers must be enabled for this parameter to work.
13 - 56 DS6708 Digital Scanner Product Reference Guide Data Matrix Parameter # F0h, 24h To enable or disable Data Matrix, scan the appropriate bar code below. *Enable Data Matrix (01h) Disable Data Matrix (00h) Maxicode Parameter # F0h, 26h To enable or disable Maxicode, scan the appropriate bar code below.
Symbologies 13 - 57 QR Code Parameter # F0h,25h To enable or disable QR Code, scan the appropriate bar code below. *Enable QR Code (01h) Disable QR Code (00h) Redundancy Level Parameter # 4Eh The digital scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the digital scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.
13 - 58 DS6708 Digital Scanner Product Reference Guide Redundancy Level 2 The following code types must be successfully read twice before being decoded: Table 13-3 Redundancy Level 2 Codes Code Type All Code Length All Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded.
Symbologies 13 - 59 Redundancy Level (continued) *Redundancy Level 1 (01h) Redundancy Level 2 (02h) Redundancy Level 3 (03h) Redundancy Level 4 (04h)
13 - 60 DS6708 Digital Scanner Product Reference Guide Security Level Parameter # 4Dh The digital scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and digital scanner aggressiveness, so choose only that level of security necessary for any given application.
Symbologies 13 - 61 Intercharacter Gap Size Parameter # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the digital scanner from decoding the symbol. If this problem occurs, scan the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes.
13 - 62 DS6708 Digital Scanner Product Reference Guide Macro PDF Features Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The digital scanner can decode symbols that are encoded with this feature, and can store more than 64 Kb of decoded data stored in up to 50 MacroPDF symbols. CAUTION When printing, keep each Macro PDF sequence separate, as each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data.
Chapter 14 Advanced Data Formatting Chapter 14 Advanced Data Formatting Introduction Advanced Data Formatting (ADF) is a means of customizing data before transmission to the host device. Scan data can be edited to suit particular requirements. ADF can be implemented through scanning a related series of bar codes, which begin on page 14-5, or by installing the 123Scan utility (see Chapter 12, 123Scan) which allows the digital scanner to be setup and programmed with Advanced Data Formatting (ADF) Rules.
14 - 2 DS6708 Digital Scanner Product Reference Guide Using ADF Bar Codes When programming a rule, make sure the rule is logically correct. Plan ahead before scanning. To program each data formatting rule: • Start the Rule. Scan the Begin New Rule bar code on page 14-5. • Criteria. Scan the bar codes for all pertinent criteria. Criteria can include code type (e.g., Code 128), code length, or data that contains a specific character string (e.g., the digits “129”).
Advanced Data Formatting 14 - 3 Rule 1: The Code 128 Scanning Rule Step Bar Code On Page Beep Indication 1 Begin New Rule 14-5 High High 2 Code 128 14-8 High High 3 Send next 5 characters 14-24 High High 4 Send 14-44 High High 5 Send next 5 characters 14-24 High High 6 Send 14-44 High High 7 Send next 2 characters 14-23 High High 8 Send 14-43 High High 9 Save Rule 14-6 High Low High Low Rule 2: The UPC Scanning Rule Step Bar Code On Page
14 - 4 DS6708 Digital Scanner Product Reference Guide But, when there is a sale, send only the following: 24 (class key) 56712437 (stock key) and the cashier will key the price manually. To implement this, first enter an ADF rule that applies to the normal situation, such as: Scan Rule Belongs to Set 1. When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, send the data that remains, send the Enter key.
Advanced Data Formatting 14 - 5 And the SECOND rule states: When scanning a Code 128 bar code of length 12, send the first four characters, then send the ENTER key, then send all remaining data. If a Code 128 bar code of length 12 were scanned, the THIRD rule would be in effect. The SECOND rule would appear to not function. Note also that ADF rules are actually created when using the standard data editing functions.
14 - 6 DS6708 Digital Scanner Product Reference Guide Save Rule Scan the bar code below to save the rule. Save Rule Erase Use these bar codes to erase criteria, actions, or rules. Erase Criteria And Start Again Erase Actions And Start Again Erase Previously Saved Rule Erase All Rules Quit Entering Rules Scan the bar code below to quit entering rules.
Advanced Data Formatting 14 - 7 Disable Rule Set Use these bar codes to disable rule sets.
14 - 8 DS6708 Digital Scanner Product Reference Guide Criteria Code Types Select any number of code types to be affected. All selected codes must be scanned in succession, prior to selecting other criteria. To select all code types, do not scan any code type. Scan the bar codes for all code types desired before selecting other criteria.
Advanced Data Formatting 14 - 9 Code Types (continued) IATA 2 OF 5 I 2 OF 5 Code 93 UPC-A UPC-E EAN-8 EAN-13
14 - 10 DS6708 Digital Scanner Product Reference Guide Code Types (continued) MSI UCC/EAN 128 UPC-E1 Bookland EAN Trioptic Code 39 Code 11 Code 32
Advanced Data Formatting 14 - 11 Code Types (continued) ISBT 128 Coupon Code US Postnet US Planet UK Postal Japan Postal Australian Postal
14 - 12 DS6708 Digital Scanner Product Reference Guide Code Types (continued) Dutch Postal PDF417 MicroPDF Macro PDF Macro MicroPDF MaxiCode Datamatrix
Advanced Data Formatting 14 - 13 Code Types (continued) QR Code TLC 39 UPC/EAN Composites RSS and EAN128 Composites NOTE When selecting composite bar codes, enable AIM IDs if parsing UPC or EAN composite data, or data from an application that uses symbol separators.
14 - 14 DS6708 Digital Scanner Product Reference Guide Code Lengths Define the number of characters the selected code type must contain. Do not select any code length to select code types of any length. Scan these bar codes to define the number of characters the selected code types must contain. Select one length per rule only.
Advanced Data Formatting 14 - 15 Code Lengths (continued) 7 Characters 8 Characters 9 Characters 10 Characters 11 Characters 12 Characters 13 Characters
14 - 16 DS6708 Digital Scanner Product Reference Guide Code Lengths (continued) 14 Characters 15 Characters 16 Characters 17 Characters 18 Characters 19 Characters 20 Characters
Advanced Data Formatting 14 - 17 Code Lengths (continued) 21 Characters 22 Characters 23 Characters 24 Characters 25 Characters 26 Characters 27 Characters
14 - 18 DS6708 Digital Scanner Product Reference Guide Code Lengths (continued) 28 Characters 29 Characters 30 Characters Message Containing A Specific Data String Use this feature to select whether the formatting affects data that begins with a specific character or data string, or contains a specific character or data string.
Advanced Data Formatting 14 - 19 Specific String, Any Location Scan the bar code below, then, using the Numeric Keypad beginning on page 14-20, scan a two-digit number representing the position (use a leading “zero” if necessary). Then scan the desired character or characters (up to a total of 8) on the Alphanumeric Keyboard beginning on page 14-86, followed by the End of Message bar code on page 14-95. After scanning the following bar code: 1.
14 - 20 DS6708 Digital Scanner Product Reference Guide Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard.
Advanced Data Formatting 14 - 21 Numeric Keypad (continued) 7 8 9 Cancel
14 - 22 DS6708 Digital Scanner Product Reference Guide Rule Belongs To Set Select the set a rule belongs to. (There are four possible rule sets.) See Alternate Rule Sets on page 14-3 for more information about rule sets. Scan a bar code below to select which set a rule belongs to.
Advanced Data Formatting 14 - 23 Actions Select how to format the data for transmission. Send Data Send all data that remains, send all data up to a specific character selected from the Alphanumeric Keyboard beginning on page 14-86, or send the next N characters. N = any number from 1 to 254 selected from the Alphanumeric Keyboard beginning on page 14-86. Use these bar codes to send data.
14 - 24 DS6708 Digital Scanner Product Reference Guide Send Data (continued) Send Next 5 Characters Send Next 6 Characters Send Next 7 Characters Send Next 8 Characters Send Next 9 Characters Send Next 10 Characters Send Next 11 Characters
Advanced Data Formatting 14 - 25 Send Data (continued) Send Next 12 Characters Send Next 13 Characters Send Next 14 Characters Send Next 15 Characters Send Next 16 Characters Send Next 17 Characters Send Next 18 Characters
14 - 26 DS6708 Digital Scanner Product Reference Guide Send Data (continued) Send Next 19 Characters Send Next 20 Characters Setup Field(s) Table 14-1 Setup Field(s) Definitions Parameter Description Page Move Cursor Move Cursor To a Character Scan the Move Cursor To Character on page 14-27, then any printable ASCII character from the Alphanumeric Keyboard beginning on page 14-86. When this is used, the cursor moves to the position after the matching character.
Advanced Data Formatting 14 - 27 Move Cursor Scan a bar code below to move the cursor in relation to a specified character. Then enter a character by scanning a bar code from the Alphanumeric Keyboard beginning on page 14-86. NOTE If there is no match when the rule is interpreted and the rule fails, the next rule is checked. Move Cursor To Character Move Cursor To Start Move Cursor Past Character Send Pause Scan the bar code below to insert a pause in the transmission of data.
14 - 28 DS6708 Digital Scanner Product Reference Guide Skip Ahead Use the following bar codes to skip ahead characters.
Advanced Data Formatting 14 - 29 Skip Ahead (continued) Skip Ahead 8 Characters Skip Ahead 9 Characters Skip Ahead 10 Characters Skip Back Use the following bar codes to skip back characters.
14 - 30 DS6708 Digital Scanner Product Reference Guide Skip Back (continued) Skip Back 4 Characters Skip Back 5 Characters Skip Back 6 Characters Skip Back 7 Characters Skip Back 8 Characters Skip Back 9 Characters Skip Back 10 Characters
Advanced Data Formatting 14 - 31 Send Preset Value Use these bar codes to send preset values. These values must be set using the Scan Prefix and Scan Suffix bar codes on page 4-13. Send Prefix Send Suffix Modify Data Modify data in the ways listed. The following actions work for all send commands that follow it within a rule. Programming pad zeros to length 6, send next 3 characters, stop padding, send next 5 characters, adds three zeros to the first send, and the next send is unaffected by the padding.
14 - 32 DS6708 Digital Scanner Product Reference Guide Stop Space Removal Scan the bar code below to disable space removal. Stop Space Removal Remove Leading Zeros Scan the bar code below to remove all leading zeros. Remove Leading Zeros Stop Zero Removal Scan the bar code below to disable the removal of zeros.
Advanced Data Formatting 14 - 33 Pad Data with Spaces To pad data to the left, scan the bar code containing the desired number of spaces. This parameter is activated by Send commands.
14 - 34 DS6708 Digital Scanner Product Reference Guide Pad Data with Spaces (continued) Pad Spaces To Length 8 Pad Spaces To Length 9 Pad Spaces To Length 10 Pad Spaces To Length 11 Pad Spaces To Length 12 Pad Spaces To Length 13 Pad Spaces To Length 14
Advanced Data Formatting 14 - 35 Pad Data with Spaces (continued) Pad Spaces To Length 15 Pad Spaces To Length 16 Pad Spaces To Length 17 Pad Spaces To Length 18 Pad Spaces To Length 19 Pad Spaces To Length 20 Pad Spaces To Length 21
14 - 36 DS6708 Digital Scanner Product Reference Guide Pad Data with Spaces (continued) Pad Spaces To Length 22 Pad Spaces To Length 23 Pad Spaces To Length 24 Pad Spaces To Length 25 Pad Spaces To Length 26 Pad Spaces To Length 27 Pad Spaces To Length 28
Advanced Data Formatting 14 - 37 Pad Data with Spaces (continued) Pad Spaces To Length 29 Pad Spaces To Length 30 Stop Pad Spaces Pad Data with Zeros To pad data to the left, scan the bar code containing the desired number of zeros. This parameter is activated by Send commands.
14 - 38 DS6708 Digital Scanner Product Reference Guide Pad Data with Zeros (continued) Pad Zeros To Length 4 Pad Zeros To Length 5 Pad Zeros To Length 6 Pad Zeros To Length 7 Pad Zeros To Length 8 Pad Zeros To Length 9 Pad Zeros To Length 10
Advanced Data Formatting 14 - 39 Pad Data with Zeros (continued) Pad Zeros To Length 11 Pad Zeros To Length 12 Pad Zeros To Length 13 Pad Zeros To Length 14 Pad Zeros To Length 15 Pad Zeros To Length 16 Pad Zeros To Length 17
14 - 40 DS6708 Digital Scanner Product Reference Guide Pad Data with Zeros (continued) Pad Zeros To Length 18 Pad Zeros To Length 19 Pad Zeros To Length 20 Pad Zeros To Length 21 Pad Zeros To Length 22 Pad Zeros To Length 23 Pad Zeros To Length 24
Advanced Data Formatting 14 - 41 Pad Data with Zeros (continued) Pad Zeros To Length 25 Pad Zeros To Length 26 Pad Zeros To Length 27 Pad Zeros To Length 28 Pad Zeros To Length 29 Pad Zeros To Length 30 Stop Pad Zeros
14 - 42 DS6708 Digital Scanner Product Reference Guide Beeps Select a beep sequence for each ADF rule.
Advanced Data Formatting 14 - 43 Control Characters (continued) Send Control C Send Control D Send Control E Send Control F Send Control G Send Control H Send Control I
14 - 44 DS6708 Digital Scanner Product Reference Guide Control Characters (continued) Send Control J Send Control K Send Control L Send Control M Send Control N Send Control O Send Control P
Advanced Data Formatting 14 - 45 Control Characters (continued) Send Control Q Send Control R Send Control S Send Control T Send Control U Send Control V Send Control W
14 - 46 DS6708 Digital Scanner Product Reference Guide Control Characters (continued) Send Control X Send Control Y Send Control Z Send Control [ Send Control \ Send Control ]
Advanced Data Formatting 14 - 47 Control Characters (continued) Send Control 6 Send Control - Keyboard Characters Scan the “Send __” bar code for the keyboard characters to send.
14 - 48 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send $ Send % Send & Send ‘ Send ( Send ) Send *
Advanced Data Formatting 14 - 49 Keyboard Characters (continued) Send + Send , Send - Send .
14 - 50 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send 2 Send 3 Send 4 Send 5 Send 6 Send 7 Send 8
Advanced Data Formatting 14 - 51 Keyboard Characters (continued) Send 9 Send : Send ; Send < Send = Send > Send ?
14 - 52 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send @ Send A Send B Send C Send D Send E Send F
Advanced Data Formatting 14 - 53 Keyboard Characters (continued) Send G Send H Send I Send J Send K Send L Send M
14 - 54 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send N Send O Send P Send Q Send R Send S Send T
Advanced Data Formatting 14 - 55 Keyboard Characters (continued) Send U Send V Send W Send X Send Y Send Z Send [
14 - 56 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send \ Send ] Send ^ Send _ Send ` Send a Send b
Advanced Data Formatting 14 - 57 Keyboard Characters (continued) Send c Send d Send e Send f Send g Send h Send i
14 - 58 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send j Send k Send l Send m Send n Send o Send p
Advanced Data Formatting 14 - 59 Keyboard Characters (continued) Send q Send r Send s Send t Send u Send v Send w
14 - 60 DS6708 Digital Scanner Product Reference Guide Keyboard Characters (continued) Send x Send y Send z Send { Send | Send } Send ~
Advanced Data Formatting 14 - 61 Send ALT Characters Send Alt 2 Send Alt A Send Alt B Send Alt C Send Alt D Send Alt E Send Alt F
14 - 62 DS6708 Digital Scanner Product Reference Guide Send ALT Characters (continued) Send Alt G Send Alt H Send Alt I Send Alt J Send Alt K Send Alt L Send Alt M
Advanced Data Formatting 14 - 63 Send ALT Characters (continued) Send Alt N Send Alt O Send Alt P Send Alt Q Send Alt R Send Alt S Send Alt T
14 - 64 DS6708 Digital Scanner Product Reference Guide Send ALT Characters (continued) Send Alt U Send Alt V Send Alt W Send Alt X Send Alt Y Send Alt Z Send Alt [
Advanced Data Formatting 14 - 65 Send ALT Characters (continued) Send Alt \ Send Alt ] Send Alt 6 Send Alt -
14 - 66 DS6708 Digital Scanner Product Reference Guide Send Keypad Characters Send Keypad * Send Keypad + Send Keypad - Send Keypad .
Advanced Data Formatting 14 - 67 Send Keypad Characters (continued) Send Keypad 2 Send Keypad 3 Send Keypad 4 Send Keypad 5 Send Keypad 6 Send Keypad 7 Send Keypad 8
14 - 68 DS6708 Digital Scanner Product Reference Guide Send Keypad Characters (continued) Send Keypad 9 Send Keypad Enter Send Keypad Numlock Send Break Key Send Delete Key Send Page Up Key Send End Key
Advanced Data Formatting 14 - 69 Send Keypad Characters (continued) Send Page Down Key Send Pause Key Send Scroll Lock Key Send Backspace Key Send Tab Key Send Print Screen Key Send Insert Key
14 - 70 DS6708 Digital Scanner Product Reference Guide Send Keypad Characters (continued) Send Home Key Send Enter Key Send Escape Key Send Up Arrow Key Send Down Arrow Key Send Left Arrow Key Send Right Arrow Key
Advanced Data Formatting 14 - 71 Send Function Key Send F1 Key Send F2 Key Send F3 Key Send F4 Key Send F5 Key Send F6 Key Send F7 Key
14 - 72 DS6708 Digital Scanner Product Reference Guide Send Function Key (continued) Send F8 Key Send F9 Key Send F10 Key Send F11 Key Send F12 Key Send F13 Key Send F14 Key
Advanced Data Formatting 14 - 73 Send Function Key (continued) Send F15 Key Send F16 Key Send F17 Key Send F18 Key Send F19 Key Send F20 Key Send F21 Key
14 - 74 DS6708 Digital Scanner Product Reference Guide Send Function Key (continued) Send F22 Key Send F23 Key Send F24 Key Send PF1 Key Send PF2 Key Send PF3 Key Send PF4 Key
Advanced Data Formatting 14 - 75 Send Function Key (continued) Send PF5 Key Send PF6 Key Send PF7 Key Send PF8 Key Send PF9 Key Send PF10 Key Send PF11 Key
14 - 76 DS6708 Digital Scanner Product Reference Guide Send Function Key (continued) Send PF12 Key Send PF13 Key Send PF14 Key Send PF15 Key Send PF16 Key Send PF17 Key Send PF18 Key
Advanced Data Formatting 14 - 77 Send Function Key (continued) Send PF19 Key Send PF20 Key Send PF21 Key Send PF22 Key Send PF23 Key Send PF24 Key Send PF25 Key
14 - 78 DS6708 Digital Scanner Product Reference Guide Send Function Key (continued) Send PF26 Key Send PF27 Key Send PF28 Key Send PF29 Key Send PF30 Key Send Right Control Key The “Send Right Control Key” action will send a tap (press and release) of the Right Control Key.
Advanced Data Formatting 14 - 79 Send Graphic User Interface (GUI) Characters The “Send Graphic User Interface Character” actions will tap the specified key while holding the System Dependent Graphic User Interface (GUI) Key.
14 - 80 DS6708 Digital Scanner Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI 6 Send GUI 7 Send GUI 8 Send GUI 9 Send GUI A Send GUI B Send GUI C
Advanced Data Formatting 14 - 81 Send Graphic User Interface (GUI) Characters (continued) Send GUI D Send GUI E Send GUI F Send GUI G Send GUI H Send GUI I Send GUI J
14 - 82 DS6708 Digital Scanner Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI K Send GUI L Send GUI M Send GUI N Send GUI O Send GUI P Send GUI Q
Advanced Data Formatting 14 - 83 Send Graphic User Interface (GUI) Characters (continued) Send GUI R Send GUI S Send GUI T Send GUI U Send GUI V Send GUI W Send GUI X
14 - 84 DS6708 Digital Scanner Product Reference Guide Send Graphic User Interface (GUI) Characters (continued) Send GUI Y Send GUI Z Turn On/Off Rule Sets Use these bar codes to turn rule sets on and off.
Advanced Data Formatting 14 - 85 Turn On/Off Rule Sets (continued) Use these bar codes to turn rule sets on and off.
14 - 86 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard Space # $ % * + (Dash)
Advanced Data Formatting 14 - 87 Alphanumeric Keyboard (continued) .
14 - 88 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard (continued) ) : ; < = > ?
Advanced Data Formatting 14 - 89 Alphanumeric Keyboard (continued) @ [ \ ] ^ _ (Underscore) `
14 - 90 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard (continued) NOTE Numeric bar codes below should not be confused with those on the numeric keypad 0 1 2 3 4 5
Advanced Data Formatting 14 - 91 Alphanumeric Keyboard (continued) 6 7 8 9 A B C
14 - 92 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard (continued) D E F G H I J
Advanced Data Formatting 14 - 93 Alphanumeric Keyboard (continued) K L M N O P Q
14 - 94 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard (continued) R S T U V W X
Advanced Data Formatting 14 - 95 Alphanumeric Keyboard (continued) Y Z Cancel End of Message a b c
14 - 96 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard (continued) d e f g h i j
Advanced Data Formatting 14 - 97 Alphanumeric Keyboard (continued) k l m n o p q
14 - 98 DS6708 Digital Scanner Product Reference Guide Alphanumeric Keyboard (continued) r s t u v w x
Advanced Data Formatting 14 - 99 Alphanumeric Keyboard (continued) y z { | } ~
14 - 100 DS6708 Digital Scanner Product Reference Guide
Standard Default Parameters Appendix A Appendix A Standard Default Parameters Table A-1 Standard Default Parameters Table Parameter Parameter Number Default Page Number User Preferences Set Default Parameter All Defaults 4-4 Parameter Scanning ECh Enable 4-4 Beeper Tone 91h Medium 4-5 Beeper Volume 8Ch High 4-5 Power Mode 80h Continuous On 4-6 Time Delay to Low Power Mode 92h 1 Minute 4-7 Trigger Mode 8Ah Auto Aim 4-8 Picklist Mode F0h 92h Disabled Always 4-9 Decode Se
A-2 DS6708 Digital Scanner Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Decoding Preferences Decoding Illumination F0h 2Ah Enable 5-3 Illumination Bank Control F1h 3Bh Full Illumination 5-4 Decode Aiming Pattern F0h 32h Enable 5-5 USB Device Type HID Keyboard Emulation 6-4 USB Country Keyboard Types (Country Codes) North American 6-5 USB Keystroke Delay No Delay 6-7 USB CAPS Lock Override Disable
Appendix A: Standard Default Parameters A - 3 Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Intercharacter Delay 0 msec 7-17 Nixdorf Beep/LED Options Normal Operation 7-18 Ignore Unknown Characters Send Bar Code 7-18 Port Address None Selected 8-4 Convert Unknown to Code 39 Disable 8-5 Wand Emulation Host Types Symbol OmniLink Interface Controller1 9-4 Leading Margin 80 msec 9-5 Polarity Bar High/Margin Low 9-6 Ignore Unk
A-4 DS6708 Digital Scanner Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Undecoded Scanner Emulation Beep Style Beep on Successful Transmit 11-4 Parameter Pass-Through Parameter Process and Pass Through 11-5 Convert Newer Code Types Convert Newer Code Types 11-5 Module Width 20 µs 11-6 Convert All Bar Codes to Code 39 Do Not Convert to Code 39 11-7 Code 39 Full ASCII Conversion Disable 11-7 Transmission
Appendix A: Standard Default Parameters A - 5 Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number UPC-E1 Preamble 24h System Character 13-15 Convert UPC-E to A 25h Disable 13-16 Convert UPC-E1 to A 26h Disable 13-16 EAN-8/JAN-8 Extend 27h Disable 13-17 UCC Coupon Extended Code 55h Disable 13-17 Code 128 08h Enable 13-18 UCC/EAN-128 0Eh Enable 13-18 ISBT 128 54h Enable 13-19 Code 39 00h Enable 13-19 Trioptic Code 39
A-6 DS6708 Digital Scanner Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF) 06h Enable 13-32 Set Lengths for I 2 of 5 16h 17h 14 13-32 I 2 of 5 Check Digit Verification 31h Disable 13-34 Transmit I 2 of 5 Check Digit 2Ch Disable 13-34 Convert I 2 of 5 to EAN 13 52h Disable 13-35 Discrete 2 of 5 05h Disable 13-35 Set Length(s) for D 2 of 5 14h 15h 12
Appendix A: Standard Default Parameters A - 7 Table A-1 Standard Default Parameters Table (Continued) Parameter Transmit US Postal Check Digit Parameter Number Default Page Number 5Fh Enable 13-48 RSS 14 F0h 52h Enable 13-49 RSS Limited F0h 53h Enable 13-49 RSS Expanded F0h 54h Enable 13-50 Convert RSS to UPC/EAN F0h 8Dh Disable 13-50 Composite CC-C F0h 55h Disable 13-51 Composite CC-A/B F0h 56h Disable 13-51 Composite TLC-39 F0h 73h Disable 13-52 UPC Composite Mode F0
A-8 DS6708 Digital Scanner Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Macro PDF Flush Macro PDF Buffer 13-62 Abort Macro PDF Entry 13-62 1 User selection is required to configure this interface and this is the most common selection.
Programming Reference Appendix B Appendix B Programming Reference Symbol Code Identifiers Table B-2 Symbol Code Characters Code Character Code Type A UPC-A, UPC-E, UPC-E1, EAN-8, EAN-13 B Code 39, Code 32 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5, or Discrete 2 of 5 IATA H Code 11 J MSI K UCC/EAN-128 L Bookland EAN M Trioptic Code 39 N Coupon Code R RSS Family T UCC Composite, TLC 39 X PDF417, Macro PDF417, Micro PDF417 P00 Data Matrix P01
B-2 DS6708 Digital Scanner Product Reference Guide Table B-2 Symbol Code Characters (Continued) Code Character Code Type P04 US Planet P05 Japan Postal P06 UK Postal P08 Dutch Postal P09 Australian Postal P09 UK Postal
Appendix B: Programming Reference B - 3 AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character (ASCII 93) c = Code Character (see Table B-3) m = Modifier Character (see Table B-4) Table B-3 Aim Code Characters Code Character Code Type A Code 39, Code 39 Full ASCII, Code 32 C Code 128, Coupon (Code 128 portion) d Data Matrix E UPC/EAN, Coupon (UPC portion) e RSS Family F Codabar G Code 93 H Code 11 I Interleaved 2 of 5 L PDF417,
B-4 DS6708 Digital Scanner Product Reference Guide The modifier character is the sum of the applicable option values based on Table B-4. Table B-4 Modifier Characters Code Type Code 39 Option Value 0 No check character or Full ASCII processing. 1 Reader has checked one check character. 3 Reader has checked and stripped check character. 4 Reader has performed Full ASCII character conversion. 5 Reader has performed Full ASCII character conversion and checked one check character.
Appendix B: Programming Reference B - 5 Table B-4 Modifier Characters (Continued) Code Type Option Value 0 D 2 of 5 UPC/EAN Code 11 No options specified at this time. Always transmit 0. Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123 0 Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data). 1 Two-digit supplement data only. 2 Five-digit supplement data only. 4 EAN-8 data packet.
B-6 DS6708 Digital Scanner Product Reference Guide Table B-4 Modifier Characters (Continued) Code Type PDF417, Micro PDF417 Data Matrix MaxiCode Option Value Option 0 Reader set to conform to protocol defined in 1994 PDF417 symbology specifications. Note: When this option is transmitted, the receiver cannot reliably determine whether ECIs have been invoked or whether data byte 92DEC has been doubled in transmission. 1 Reader set to follow the ECI protocol (Extended Channel Interpretation).
Appendix B: Programming Reference B - 7 Table B-4 Modifier Characters (Continued) Code Type QR Code Option Value Option 0 Model 1 symbol. 1 Model 2 symbol, ECI protocol not implemented. 2 Model 2 symbol, ECI protocol implemented. 3 Model 2 symbol, ECI protocol not implemented, FNC1 implied in first position. 4 Model 2 symbol, ECI protocol implemented, FNC1 implied in first position. 5 Model 2 symbol, ECI protocol not implemented, FNC1 implied in second position.
B-8 DS6708 Digital Scanner Product Reference Guide
Sample Bar Codes Appendix C Appendix C Sample Bar Codes Code 39 123ABC UPC/EAN UPC-A, 100% 0 12345 67890 5
C-2 DS6708 Digital Scanner Product Reference Guide EAN-13, 100% 3 456789 012340 Code 128 12345678901234567890123456789012345678901234 Interleaved 2 of 5 12345678901231
Appendix C: Sample Bar Codes C - 3 RSS 14 NOTE RSS 14 must be enabled to read the bar code below (see RSS-14 on page 13-49).
C-4 DS6708 Digital Scanner Product Reference Guide Maxicode QR Code US Postnet
Appendix C: Sample Bar Codes C - 5 UK Postal
C-6 DS6708 Digital Scanner Product Reference Guide
Appendix D Numeric Bar Codes Appendix D Numeric Bar Codes Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
D-2 DS6708 Digital Scanner Product Reference Guide Numeric Bar Codes (continued) 5 6 7 8 9 Cancel To correct an error or change a selection, scan the bar code below.
ASCII Character Sets Appendix E Appendix E ASCII Character Sets Table E-1 ASCII Value Table ASCII Value Full ASCII Code 39 Encode Char Keystroke 1000 %U CTRL 2 1001 $A CTRL A 1002 $B CTRL B 1003 $C CTRL C 1004 $D CTRL D 1005 $E CTRL E 1006 $F CTRL F 1007 $G CTRL G 1008 $H CTRL H/BACKSPACE1 1009 $I CTRL I/HORIZONTAL TAB1 1010 $J CTRL J 1011 $K CTRL K 1012 $L CTRL L 1013 $M CTRL M/ENTER1 1014 $N CTRL N 1015 $O CTRL O 1016 $P CTRL P 1017 $Q CTRL Q 1
E-2 DS6708 Digital Scanner Product Reference Guide Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1020 $T CTRL T 1021 $U CTRL U 1022 $V CTRL V 1023 $W CTRL W 1024 $X CTRL X 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [ 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J
Appendix E: ASCII Character Sets E - 3 Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1047 /o / 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 /Z : 1059 %F ; 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I The keystroke in bold is sent only if the
E-4 DS6708 Digital Scanner Product Reference Guide Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ‘ 1097 +A a 1098 +B b 1099 +C c 1100 +D d The keystroke in bold is se
Appendix E: ASCII Character Sets E - 5 Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1101 +E e 1102 +F f 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q I 1125 %R } 1126 %S ~ The keystroke in bold is sent only i
E-6 DS6708 Digital Scanner Product Reference Guide Table E-2 ALT Key Standard Default Tables ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z
Appendix E: ASCII Character Sets E - 7 Table E-3 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key
E-8 DS6708 Digital Scanner Product Reference Guide Table E-3 USB GUI Key Character Set (Continued) GUI Key Keystroke 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windows-based systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key.
Appendix E: ASCII Character Sets E - 9 Table E-4 PF Key Standard Default Table (Continued) PF Keys Keystroke 4014 PF 14 4015 PF 15 4016 PF 16
E - 10 DS6708 Digital Scanner Product Reference Guide Table E-5 F key Standard Default Table F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F 18 5019 F 19 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24
Appendix E: ASCII Character Sets E - 11 Table E-6 Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 * 6043 + 6044 Undefined 6045 - 6046 .
E - 12 DS6708 Digital Scanner Product Reference Guide Table E-7 Extended Keypad Standard Default Table (Continued) Extended Keypad Keystroke 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow
Glossary GlossaryGlossary A API. An interface by means of which one software component communicates with or controls another. Usually used to refer to services provided by one software component to another, usually via software interrupts or function calls Aperture. The opening in an optical system defined by a lens or baffle that establishes the field of view. Application Programming Interface. See API. ANSI Terminal. A display terminal that follows commands in the ANSI standard terminal language.
Glossary - 2 Bit. Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning. Bits per Second (bps). Bits transmitted or received. Bit. Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning. bps. See Bits Per Second. Byte.
Glossary - 3 Code 3 of 9 (Code 39). A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9 and 7 special characters (- . / + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow. Code 93. An industrial symbology compatible with Code 39 but offering a full character ASCII set and a higher coding density than Code 39.
Glossary - 4 Discrete 2 of 5. A binary bar code symbology representing each character by a group of five bars, two of which are wide. The location of wide bars in the group determines which character is encoded; spaces are insignificant. Only numeric characters (0 to 9) and START/STOP characters may be encoded. DRAM. Dynamic random access memory. DTE. See Data Terminal Equipment. E EAN. European Article Number.
Glossary - 5 Host Computer. A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs and network control. I IDE. Intelligent drive electronics. Refers to the solid-state hard drive type. IEC. International Electrotechnical Commission. This international agency regulates laser safety by specifying various laser operation classes based on power output during operation. IEC (825) Class 1.
Glossary - 6 IP Address. (Internet Protocol address) The address of a computer attached to an IP network. Every client and server station must have a unique IP address. A 32-bit address used by a computer on a IP network. Client workstations have either a permanent address or one that is dynamically assigned to them each session. IP addresses are written as four sets of numbers separated by periods; for example, 204.171.64.2. IPX/SPX. Internet Package Exchange/Sequential Packet Exchange.
Glossary - 7 MDN. Mobile Directory Number. The directory listing telephone number that is dialed (generally using POTS) to reach a mobile unit. The MDN is usually associated with a MIN in a cellular telephone -- in the US and Canada, the MDN and MIN are the same value for voice cellular users. International roaming considerations often result in the MDN being different from the MIN. MIL. 1 mil = 1 thousandth of an inch. MIN. Mobile Identification Number.
Glossary - 8 Parameter. A variable that can have different values assigned to it. PC Card. A plug-in expansion card for laptop computers and other devices, also called a PCMCIA card. PC Cards are 85.6mm long x 54 mm wide, and have a 68 pin connector. There are several different kinds: Type I; 3.3 mm high; use - RAM or Flash RAM Type II; 5 mm high; use - modems, LAN adaptors Type III; 10.5 high; use - Hard Disks PCMCIA. Personal Computer Memory Card Interface Association. See PC Card. Percent Decode.
Glossary - 9 Router. A device that connects networks and supports the required protocols for packet filtering. Routers are typically used to extend the range of cabling and to organize the topology of a network into subnets. See Subnet. RS-232. An Electronic Industries Association (EIA) standard that defines the connector, connector pins, and signals used to transfer data serially from one device to another. S Scan Area. Area intended to contain a symbol. Scanner.
Glossary - 10 Subnet Mask. A 32-bit number used to separate the network and host sections of an IP address. A custom subnet mask subdivides an IP network into smaller subsections. The mask is a binary pattern that is matched up with the IP address to turn part of the host ID address field into a field for subnets. Default is often 255.255.255.0. Substrate. A foundation material on which a substance or image is placed. SVTP. Symbol Virtual Terminal Program. Symbol.
Glossary - 11 Tolerance. Allowable deviation from the nominal bar or space width. Transmission Control Protocol/Internet Protocol. See TCP/IP. Trivial File Transfer Protocol. See TFTP. TSR. See Terminate and Stay Resident. U UPC. Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which is any of four widths. The standard symbology for retail food packages in the United States. UDP. User Datagram Protocol.
Glossary - 12
Index Index Numerics 123Scan parameters . . . . . . . . . . . . . . . . . . . . . . . . 12-2 2D bar codes code 128 emulation . . . . . . . . . . . . . . . . . . . . 13-55 Data Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-56 Maxicode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-56 MicroPDF417 . . . . . . . . . . . . . . . . . . . . . . . . . 13-54 PDF417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-54 QR code . . . . . . . . . . . . . . . . . . . . . . . . .
Index - 2 DS6708 Digital Scanner Product Reference Guide specific data string . . . . . . . . . . . . . . . . . . . . . 14-18 turn off rule sets . . . . . . . . . . . . . . . . . .14-84, 14-85 zero removal . . . . . . . . . . . . . . . . . . . . . . . . . . 14-31 aiming options decode aiming pattern . . . . . . . . . . . . . . . . . . . . 5-5 aiming pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 enabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index - 3 ignore unknown characters . . . . . . . . . . . . 11-9 leading margin . . . . . . . . . . . . . . . . . 11-9, 11-10 module width . . . . . . . . . . . . . . . . . . . . . . . 11-6 parameter pass-through . . . . . . . . . . . . . . . 11-5 transmission timeout . . . . . . . . . . . . . . . . . 11-8 scanner emulation host . . . . . . . . . . . . . . . . . . 11-4 set defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 supplementals . . . . . . . . . . . . . . . . . . . . . . . . .
Index - 4 DS6708 Digital Scanner Product Reference Guide full ASCII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-24 lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-21 transmit check digit . . . . . . . . . . . . . . . . . . . . . 13-23 code 93 bar codes code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-27 lengths . . . . . . . . . . . . . . . . . . . . . . . . .13-27, 13-28 code identifiers AIM code IDs . . . . . . . . . . . . . . . . . . . . . .
Index - 5 check digits . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-43 lengths . . . . . . . . . . . . . . . . . . . . . . . . . 13-41, 13-42 MSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-41 transmit check digit . . . . . . . . . . . . . . . . . . . . . 13-43 P parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 PDF417 bar codes . . . . . . . . . . . . . . . . . . . . . . . . 13-54 pinouts scanner signal descriptions . . . . . . . . .
Index - 6 DS6708 Digital Scanner Product Reference Guide
Tell Us What You Think... We’d like to know what you think about this Manual. Please take a moment to fill out this questionnaire and fax this form to: (631) 738-4618, or mail to: Symbol Technologies, Inc. One Symbol Plaza M/S B-10 Holtsville, NY 11742-1300 Attention: Advanced Data Capture Technical Publications Manager important If you need product support, please call the appropriate customer support number provided. Unfortunately, we cannot provide customer support at the fax number above.
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 http://www.symbol.