MN000995A01.
MN000995A01.fm Page 2 Tuesday, August 26, 2014 2:27 PM 2 EMG101 Gateway Symbol® is a registered trademark, and The Enterprise Mobility Company is a trademark of Symbol Technologies, Inc. All other trademarks and service marks are proprietary to their respective owners. © 2014 Symbol Technologies, Inc. All Rights Reserved.
MN000995A01.fm Page 3 Tuesday, August 26, 2014 2:27 PM Installation Guide 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . .
MN000995A01.fm Page 4 Tuesday, August 26, 2014 2:27 PM 4 EMG101 Gateway 5.7 US and Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.8 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.9 Radio Frequency Interference Requirements - FCC . . . . . . . . . . . . . . . . . . . . . . 18 5.10 Radio Frequency Interference Requirements - Canada . . . . . . . . . . . . . . . . . .
MN000995A01.fm Page 5 Tuesday, August 26, 2014 2:27 PM Installation Guide 5 1 Introduction EMG101 Gateways are components of Symbol Technologies Wireless Controller System. An EMG101 Gateway links to wireless 802.15.4 electronic shelf label tags. It installs in minutes anywhere a CAT-5e (or better) cable is located. The EMG101 Gateway ships with two single-band 2.4GHz 802.15.4 radios. The radios are configured for redundant operation.
MN000995A01.fm Page 6 Tuesday, August 26, 2014 2:27 PM 6 EMG101 Gateway 1.3 Site Preparation To prepare your deployment site for gateway installation: • Consult your site survey and network analysis reports to determine specific equipment placement, power drops, and so on. • Assign installation responsibility to the appropriate personnel.
MN000995A01.fm Page 7 Tuesday, August 26, 2014 2:27 PM Installation Guide 2 7 Hardware Installation 2.1 Installation Instructions The EMG101 Gateway can attach to a wall or mount under a suspended T-Bar. Select a mounting option based on the physical environment of the coverage area. Do not mount the EMG101 Gateway in a location not approved in a site survey. To prepare for the installation: 1. Verify the contents of the box includes the intended EMG101 Gateway and accessory hardware. 2.
MN000995A01.fm Page 8 Tuesday, August 26, 2014 2:27 PM 8 EMG101 Gateway 2.3 EMG101 Gateway Placement For optimal performance, install the EMG101 Gateway away from transformers, heavy-duty motors, fluorescent lights, microwave ovens, refrigerators and other industrial equipment. Signal loss can occur when metal, concrete, walls or floors block transmission. Install the EMG101 Gateway in an open area or add additional gateways as needed to improve coverage. Antenna coverage is analogous to lighting.
MN000995A01.fm Page 9 Tuesday, August 26, 2014 2:27 PM Installation Guide 9 The Power Injector has no On/Off power switch. The Injector receives power and is ready for device connection and operation as soon as AC power is applied. Refer to the Installation Guide shipped with the Power Injector for a description of the device’s LED. The Power Injector can be installed free standing, on an even horizontal surface or wall mounted using the Power Injector’s wall mounting key holes.
MN000995A01.fm Page 10 Tuesday, August 26, 2014 2:27 PM 10 EMG101 Gateway ! CAUTION NOTE EMG101 must only be connected to PoE networks without any connections to an outside plant power source. If not using the Power Injector to power the EMG101 Gateway, the only other approved power solution is the standard power supply (Part Number PWRS-147376-01R).
MN000995A01.fm Page 11 Tuesday, August 26, 2014 2:27 PM Installation Guide 11 c. Ensure the cable length from the Ethernet source (host) to the Power Injector and EMG101 Gateway does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information, see Power Injector System. For power adapter (Part Number PWRS-147376-01R) and line cord installations: a.
MN000995A01.fm Page 12 Tuesday, August 26, 2014 2:27 PM 12 EMG101 Gateway For power adapter (Part Number PWRS-147376-01R) and line cord installations: 4. 5. 6. 7. 8. a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) and the Gateway’s GE1/PoE. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable to the DC-48V power connector on the Gateway. e.
MN000995A01.fm Page 13 Tuesday, August 26, 2014 2:27 PM Installation Guide 13 2.7 LED Indicator The EMG101 Gateway has a single LED on the front of the unit. When the EMG101 Gateway is not powered up, the LED will be amber. When the EMG101 Gateway is powered up and running, the LED will be green.
MN000995A01.fm Page 14 Tuesday, August 26, 2014 2:27 PM 14 3 EMG101 Gateway Basic Gateway Configuration To provide the EMG101 Gateway with a basic configuration: 1. Power up the Gateway. 2. By default, the Gateway will obtain an IP address from the DHCP server. 3. If no DHCP server is available, a Static IP address should be configured. You will need to contact Symbol technical support to obtain a valid password. 4. To configure a Static IP address: a. Connect to the Gateway via the Console port. b.
MN000995A01.fm Page 15 Tuesday, August 26, 2014 2:27 PM Installation Guide 4 15 Specifications 4.1 Electrical Characteristics An EMG101 Gateway has the following electrical characteristics: Max DC Power Consumption 6W (125mA@48V) 4.2 Physical Characteristics An EMG101 Gateway has the following physical characteristics: Dimensions 6.0 (Length) x 5.5 (Width) x 1.63 (Tall) - Inches 152.4 (Length) x 139.7 (Width) x 41.1 (Tall) - Millimeters Housing Plastic Weight 0.60 lbs/0.
MN000995A01.fm Page 16 Tuesday, August 26, 2014 2:27 PM 16 5 EMG101 Gateway Regulatory Information 5.1 Regulatory Overview This device is approved under Symbol Technologies, Inc. This guide applies to Model Number EMG101. Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local language translations are available at the following website: https://portal.motorolasolutions.
MN000995A01.fm Page 17 Tuesday, August 26, 2014 2:27 PM Installation Guide 17 5.3 Health and Safety Recommendations 5.3.1 Warnings for the use of Wireless Devices Please observe all warning notices with regard to the usage of wireless devices. Pacemakers Pacemaker manufacturers recommended that a minimum of 15cm (6 inches) be maintained between a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker.
MN000995A01.fm Page 18 Tuesday, August 26, 2014 2:27 PM 18 EMG101 Gateway 5.6 Europe Electronic Shelf Gateway To comply with EU RF exposure requirements, this device must be used according to installation instructions. Other operating configurations should be avoided. To satisfy EU RF exposure requirements, a transmitting device must operate with a minimum separation distance of 20 cm or more from a person's body. 5.
MN000995A01.
MN000995A01.fm Page 20 Tuesday, August 26, 2014 2:27 PM 20 EMG101 Gateway Cet appareil est conforme avec Industrie Canada RSS exemptes de licence. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut pas provoquer d'interférences, et (2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de l'appareil.
MN000995A01.fm Page 21 Tuesday, August 26, 2014 2:27 PM Installation Guide 21 5.13 Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Symbol for recycling. For information on how to return product, please go to: http://www.motorolasolutions.com/recycling/weee. Français: Clients de l'Union Européenne: Tous les produits en fin de cycle de vie doivent être retournés à Symbol pour recyclage.
MN000995A01.fm Page 22 Tuesday, August 26, 2014 2:27 PM 22 EMG101 Gateway Dansk: Til kunder i EU: Alle produkter skal returneres til Symbol til recirkulering, når de er udtjent. Læs oplysningerne om returnering af produkter på: http://www.motorolasolutions.com/recycling/weee. Ελληνικά: Για πελάτες στην Ε.Ε.: Όλα τα προϊόντα, στο τέλος της διάρκειας ζωής τους, πρέπει να επιστρέφονται στην Symbol για ανακύκλωση.
MN000995A01.fm Page 23 Tuesday, August 26, 2014 2:27 PM Installation Guide 6 23 Support Information If you have a problem with your equipment, contact support for your region. Contact information is available at: https://portal.motorolasolutions.
MN000995A01.
MN000995A01.
MN000995A01.
MN000995A01.
MN000995A01.fm Page 28 Tuesday, August 26, 2014 2:27 PM Symbol Technologies, Inc One Symbol Plaza Holtsville, New York 11742-1300 http://www.symbol.com Symbol® is a registered trademark, and The Enterprise Mobility Company is a trademark of Symbol Technologies, Inc. All other trademarks and service marks are proprietary to their respective owners. © 2014 Symbol Technologies, Inc. All Rights Reserved.