MRC-921 MicroBase User's Guide

Both LEDs for the PTC are blinking
Make sure the PTC is installed correctly in its bay.
Exchange the battery pack in the PTC-921 with the
spare battery pack.
Refer to page 9 for information on
disposing of your nickel-cadmium
battery pack.
If the LEDs stop blinking, the first battery pack is
faulty and must be discarded.
If both LEDs continue to blink, call your Telxon
service representative.
Both LEDs for the spare battery pack are
blinking
Make sure the battery pack is installed correctly in
its bay.
Exchange the spare battery pack with the battery
pack in the PTC-921.
Refer to page 9 for information on
disposing of your nickel-cadmium
battery pack.
If the LEDs stop blinking, the spare battery pack is
faulty and must be discarded.
If both LEDs continue to blink, call your Telxon
service representative.
The battery pack in the PTC or spare battery
bay takes too long to recharge
Make sure the battery pack is inserted correctly.
Clean the contacts on the battery pack.
Try another battery pack to make sure the
MRC-921 is working correctly.
If the battery pack still takes too long to recharge,
call your Telxon service representative.