User's Manual

SYMEO Local Positioning Radar System
LPR-1DXi
Product Documentation
System Description
Copyright © Symeo GmbH 2009
Page 10 of 33
2.4.3 Frequency channel
The measurement takes place in a frequency band width of 5,725 to 5,875 GHz. In this band
width a frequency channel is assigned to the LPR-1DXi system. 30 different frequency
channels are available. Two units in one LPR-1DXi system need the same frequency
channel.
If there are more LPR-1DXi systems in your environment each further LPR-
1DXi system needs different frequency channels. The frequency channel is
linked to the group ID. Therefore it is required to use different group IDs for
different LPR-1DXi systems in the same environment. You can set the
group IDs with the commissioning tool LPR-1DXi Symeo Wizard (see
chapter 5).
2.5 Versions of LPR-1DXi stations
For the LPR-1DXi stations several different versions are available:
Overview: Options
ID
Switching threshold /
distance reading
Distance output
resolution
Basic device
BSB000719
0 to 120 m
0,5m increments
Option 1
BSB000754
0 to 500 m
0,5m increments
Option 2
BSB000755
0 to 120 m
Resolution up to ±5 cm
Option 3
BSB000756
0 to 500 m
Resolution up to ±5 cm
Basic device
*1
BSB000900
0 to 120 m
0,5m increments
Option 1
*1
BSB000901
0 to 500 m
0,5m increments
Option 2
*1
BSB000902
0 to 120 m
Resolution up to ±5 cm
Option 3
*1
BSB000903
0 to 500 m
Resolution up to ±5 cm
*1
in compliance with part 15 off FCC rules and with RSS-210 of Industry Canada
Please take care that the distances for the switching points in your
application are within the maximum possible distance range of your version
of LPR-1DXi.
The distance for positive signal control, monitoring the functionality of two
stations, is possible up to 1800m.