User's Manual

SYMEO Local Positioning Radar System
LPR-1DXi
Product Documentation
Hardware
Copyright © Symeo GmbH 2009
Page 12 of 33
The antenna C has to be mounted in correct polarization (C2) as
shown in Figure 3
3.2 Cable glands, interfaces and LED display of the LPR-1DXi
station
The casing B has two cable glands for power cable (B6) and cable for the connection to the
on-board relays (B5). Additionally the pressure equalization membran (B7) is shown.
Figure 4: Casing B side view with cable glands and mounting bracket A
B5 Cable gland for cable to relays
B6 Cable gland for power cable with optional wires for serial RS232
B7 pressure equalization membrane
Pressure equalization membran (B7) must not be removed or
loosened. Otherwise the housing will not be sealed in a water-proof
manner.
Power supply cable must be within 5 to 9 mm diameter, and relay
cable must be within 7 to 13 mm diameter, both with a round cross-
section.