User's Manual

SYMEO Local Positioning Radar System
LPR-1DXi
Product Documentation
Commissioning
Copyright © Symeo GmbH 2009
Page 23 of 33
5.2.3.2 Settings of LPR-1DXi System Parameters
After selecting the application some common settings of the LPR-1D system must be done.
Select the menu ‚Application„ and the submenu ‚LPR settings„.
Figure 21 General settings 1 of LPR-1D system
Figure 22 General settings 2 of LPR-1D system
The ‚Common Settings„ include settings of
the LPR-1DXi systems. You have to set
these parameters.
Group ID: Clear ID of the LPR-1DXi
system. The two stations in one LPR-1DXi
system must have the same group ID.
SCIB-data rate: Transmission rate of the
distance reading available on the RS232
interface on terminal block B3 of the LPR-
1DXi system. Per default this value is set to
115200 baud.
If you change the baud rate,
you should also adjust the
measurement rate of the
system.
Measurement rate: Adjust the desired
measurement rate of the system.
Depending on the application you can
choose measurement rates of 35ms to
250ms.
If more than one LPR-1DXi
system is used in the same
environment you have to
use different group IDs for
each pair of LPR-1DXi
stations.
The frequency channel
used for measurements is
linked to the group ID of
the LPR-1DXi system.