3 Mounting and Alignment of LPR
®
-1D24 Units
The device must be secured against falling.
All mounting, installation and maintenance work must be carried out by
electrician or a person with similar training and skills!
The LPR
®
-1D24 units are delivered with a separate mounting bracket (see Figure 2).
Figure 2 shows a complete system including the mounting bracket. The bracket must be
mounted with a pipe clamp on a pipe. The pipe diameter is best chosen between 40 mm and
75 mm. For mounting, a flat wrench of SW 13 is required.
For mounting the system, please proceed as follows:
At a suitable place, mount the LPR
®
-1D24 unit to a suitable pipe with the bracket. To
adjust the system, do not tighten the mounting bracket finally. Specified alignments have
to be adhered to if indicated by Symeo.
A minimum distance of 3 meters between the measuring system units must be
maintained to guarantee the specified accuracy. Mounting closer than the minimum
distance decreases the accuracy at close proximity.
The units must have the same orientation for mounting, for example both units with
connectors downwards. For outdoor use the units have to be mounted with the
connectors downwards.
Now adjust the system on the opposite side.
The two system units should be mounted opposite to each other and possibly should not
be an offset horizontal and vertical from each other or twisted.
Now fix the system by tightening the screws in the mounting bracket and the mounting
bracket on pipe in such a way that no modification is possible anymore. Flat wrench SW
13 is required.
Figure 2: LPR
®
-1D24 unit inclusive mounting bracket