Safety Instructions
Table Of Contents
- Overview
- System Description
- Hardware
- Installation
- Commissioning
- Web Server
- Protocol Description Binary XP (1D messages)
- Trouble Shooting
- Appendix A: Agency certifications
SYMEO LPR
®
LPR-1D
Product Documentation
Hardware
Copyright © Symeo GmbH 2010
Page 22 of 87
Figure 10 Cable for power supply with integrated interface
PIN-Assignment of Cable Lumberg Connector 0223 08
Plug
Lumberg 0223 08
Cable
8-wire AWG24 UL/CSA; cladding diameter = 6.4mm
Color (DIN 47100)
Pin / color
Function
1 – white
UBB (+)
2 – brown
UBB (-)
3 – green
LPR
®
Dataport RXD
4 – yellow
LPR
®
Dataport TXD
5 – grey
Network diagnostics port RXD
6 – pink
Network diagnostics port TXD
7 – blue
GND-RS232
8 – red
GND-RS232 and shielding
Consider the dependency of the maximum baud rate according to the cable
length:
15m: 19.200baud
5m: 57.600baud
<2m: 115.200baud
According to the cable length the baud rate at the stations has to be adjusted.
If this cable is only used for power supply, the RXD-wires of the cable must
be terminated. Otherwise signals from other systems can disturb the