3.3 LPR
®
Connection Box
The connection box is configured with 14 clamps. Therefore the connector box can be used
either for power supply or for relays.
Figure 12 Connection Box
Connection Box
Size (LxWxH)
125mm x 80mm x 57mm (without cable bushing)
Position mounting holes
4 x diameter 4.3mm; 52 x 113mm
Clamps
Wago 870-911 for cable diameter 0.08 till 2,5mm² ( till 4mm² if flexible
cables)
Cable bushing
3 x PG Connection for cladding diameter 5 10 mm
1 x sealing cap
Protection category
IP65
If usage of appropriate cables (diameter 5 till 8mm) and correct
connection of cap and cable bushing is assured
If the cable bushing are not used the sealing cap (including the sealing ring)
has to be mounted to keep the protection category IP65.