4 Installation
4.1 Installation of LPR
®
Station Design Compact Station
4.1.1 Important Instructions for Installation
During Installation, the Compact Station has to be opened. Therefore it is
important to avoid ingress of moisture, dust or any particles into the
housing during the installation process. Make sure that there is enough
room for the connectors, and particularly that the antenna cable is
accessible; pay attention to the permitted bending radius (center of radius
to cable core) for standard cables of 10,5cm (for multiple bending under
mechanical load) and 4cm (unloaded and static bending).
The Compact Station should preferably be installed so that the connecting
sockets point downwards. In this way, the connections are protected from
rain and dust.
4.1.2 Installation
To install the Compact Station, you require
4 round head M6 x 30 screws (at least).
Check the position of the station on the device on which the Compact Station is to be
installed (e.g. a crane bridge). Bear in mind the installation instructions listed above.
Drill holes in the device on which the Compact Station is to be installed. Drill-hole
distances: 11 cm wide, 24 cm high (see figure 7).
Open the Compact Station: With a Phillips screwdriver (Size 0), loosen the top four
screws of the Compact Station lid.
Screw the Compact Station tightly to the device. The installation holes shown in figure 2
are provided for this purpose. Check that the station is mounted securely.
Close the station: Place the cover of the Compact Station on top and fasten the cover
with the four screws. Make sure that the cover is securely attached to the housing.
Commission the Compact Station (see chapter "Base Station Initialization")
4.2 Installation of LPR
®
Antennas
4.2.1 Connecting and Wiring up the Antenna and Cable
Connect the antennas to the antenna port at the LPR
®
station.
When using several antennas, ensure that they are connected to the
correct ports.