Safety Instructions

Table Of Contents
SYMEO LPR
®
LPR-1D
Product Documentation
Commissioning
Copyright © Symeo GmbH 2010
Page 36 of 87
Possible Connection to the LPR
®
Station via PC
RS232
TCP/IP
Wireless-Access
(via another LPR
®
Station)
Parameterization
(ASCII-Data)
YES
(ASCII-Port)
YES
(ASCII-Port)
YES
(ASCII-Port)
Distance Data
(Binary Data)
YES
(Binary Port)
YES
(Binary Port)
NO
In one LPR
®
system all distance data (binary data/ protocol) is available at each station. Also
if you have several stations in one system (crane bridge, crane crab, wall) you get the binary
data at each LPR
®
station in this system.
5.2 Connection to LPR
®
Station with TCP/IP Interface
With delivery the LPR
®
stations have the fixed IP-Address 192.168.1.99, if
no other IP-Address is labeled outside the LPR
®
station.
You can change the IP-Address of the LPR
®
Station via the web interface of the LPR
®
Station.
To get a connection between your PC and the LPR
®
station it is maybe
neccessary to change the network parameters of your computer. Both units
must be located in the same network. That means in this example that the
first three numeric pads of both IP-addresses must be the same.
Disconnect your PC from the network. Connect the LPR
®
station and the computer with a
network cable. Open your network settings of your computer.
Figure 21 Network Settings
Enter the following fixed IP-
Address i.e. 192.168.1.1. The
subnet mask should be set to
255.255.255.0.
Click in both windows OK.