Page 37 of 87
If you firewall settings are too restrictive, you may not get access to the
LPR
®
station. In this case deactivate temporarely the firewall under the tab

The LPR
®
Station should be available via your PC now. You can check the connection with a

®
station:
Open the Command-Window:
Windows Start Button
Choose Run
Enter cmd and click OK
Enter in the cmd.exe window: ping 192.168.1.99 or the IP-address of the LPR
®
station.
Figure 22 Ping LPR
®
Station
The LPR
®

5.3 Connection LPR
®
Station with serial Interface
The interface RS232 is only available for station without TCP/IP interface. If
a RS232 interface for station with TCP/IP interface is desired, please
contact the Symeo Service.
The commissioning could either be done via the serial interface of the 8-pin Lumberg
connector (Figure 23) or the serial interface inside the box (Figure 25).
Consider the dependency of the maximum baud rate according to the cable
length:
15m: 19.200baud
5m: 57.600baud
<2m: 115.200baud
According to the cable length the baud rate at the stations has to be adjusted.