Figure 35 General settings 1 of LPR
®
system
Figure 36 General settings 2 of LPR
®
system

®
Systems. You have to make these settings.
Group ID:
Clear ID of the LPR
®
system. All
station in one LPR
®
system have the same
group ID.
SCIB-data rate:
Transmission rate of the LPR
®
system. Per default this value iss et to 115200
baud.
If you change the baud rate,
you should also adjust the
measurement rate of the
system.
Region:
Choose the region where the system is
installed. This is important to calculate the
allowed transmission power.
Measurement rate:
Adjust the desired
measurement rate of the system Depending on
the application you can choose measurement
rates of 35 ms to 250 ms.
If more than one LPR
®
system is used you have to
use for each system a
different group ID.
You cannot select in the
Wizard the frequency
channel because this is
linked to the group ID of the
system.
Figure 37 General settings 3 of LPR
®
B system

clude the
settings of the antenna parameters.
This is important to calculate the allowed
transmission power.
It is important to note the
right allocation the antenna
cables to the right antenna
ports. Station 2 and 3 always
use only antenna port 1. At
station the antenna which
measures with station 2 is
connected to port 1, the
antenna which measures
with station 3 is connected to
port 3.