In "DHCP Active" mode this address is assigned by the server and cannot
be edited.
Syslog
IP address of the Syslog server (default: 0.0.0.0, i.e. this service has been
disabled).
The Syslog server is a server on the network to which it is planned to have
system messages (system log) transmitted. Transmission is packet-based
(UDP) and unencrypted.
NTP
IP address of the NTP server (default: 0.0.0.0, i.e. this service has been
disabled).
The NTP server is a server on the network from which the system can
request the current time.
6.2.3 „Serial-to-Ethernet“ Area
ttyAM1
Port number of the TCP/IP port via which the data from serial port (ttyAM1)
is sent and received. ttyAM1 is the port for the parameterization interface
(Service Port). (Default: 3045)
ttyAM2
Port number of the TCP/IP port via which the data from serial port (ttyAM2)
is sent and received. ttyAM2 is the port for the data interface (Binary Port).
(default: 3046)
Per default these two ports are not enabled. Choose the Connection Type
between the LPR
®
station and your PC or PLC for each port. Depending on
the connection you select different masks are editable.
ttyAM1 / Parameterization Port
Network Settings Area:
IP (Server)
TCP Connecting to Data Port
using Reserve Port-address of the
server, to which the connection should be established.
Data Port
Port-Number of TCP/IP Port. Data of serial interface (ttyAM1)
is sent and received. ttyAM1 is the parameterization port.
Default value is 3045.
Reverse Port
TCP Connecting to Data Port
using Reverse Port
should use for the reverse channel.
Serial Settings Area
Speed
Baud rate of serial interface (ttyAM1). The baud rate of the
parameterization port is set to 115200 baud per default.
Options
Settings of serial interface ttyAM1 for the data protocol.
These settings are not necessary to change and are set per
default to raw echo ixon (Raw data, no echo, no control
character).
Connection Type Area