Safety Instructions

Table Of Contents
SYMEO LPR
®
LPR-1D
Product Documentation
Protocol Description Binary XP (1D messages)
Copyright © Symeo GmbH 2010
Page 70 of 87
7E
hex
START byte
02
hex
TYPE (02; Send Request)
C1 81
hex
CRC
7F
hex
END byte
Distance data:
7E 00 08 03 08 02 11 00 00 10 62 00 00 00 7A E6 00 00 AF C4 7F
7E
hex
START byte
00
hex
TYPE (00: Distance Data)
08 03
hex
=
00001|0000000001|1
bin
Source LPR®-B address: SID: 1; GID: 1; BBt: 1 (base
station)
08 02
hex
=
00001|0000000001|0
bin
Destination LPR®-B address: SID: 1; GID: 1; BBt: 0
(transponder)
11
hex
= 0001|0001
bin
Antenna port base station: 1 antenna port
transponder: 1
00 00 10 62
hex
= 4194
dec
Distance: 4194 mm
00 00 00 7A
hex
= 122
dec
Velocity: 122 mm/s
E6
hex
= 230
dec
Level: 230 256 = -26 dB
00
hex
Error status: 0 means no error; unequal 0 means
error (see chapter 7.4.2)
00
hex
Status
AF C4
hex
CRC
7F
hex
END byte
7.2.2 Type 0x01 User Data
User Data can be integrated at a LPR
®
-B station via the serial interface and then transmitted
to another LPR
®
-B station via the frequency channel. There the user data can be readout.
Direction: LPR
®
-
Content
Length
Data type
Value
START
1
unsigned integer
0x7E
TYPE
1
unsigned integer
0x01
Source (LPR
®
-B address)
2
see chapter 7.4.1
0x####
User Data
8
depends on
application
0x#### #### ####
####
CRC
2
unsigned integer
0x####
END
1
unsigned integer
0x7F