If you want to use a longer serial cable you have to reduce the baud rate of
the LPR-B station. Ask the Symeo Service for detailed information.
Typical values for the data rate for different length of the serial cables are:
Max. baud
rate
Max. Length of RS232
cable
9.600
152 m
19.200
15 m
57.600
5 m
115.200
<2 m
8.4 Connection inside the LPR-B station
To analyze the serial connection between your PC and the LPR-B station it is the best to
connect the serial cable inside the LPR-B station. Open the LPR-B station. Make sure that
you do not pollute anything inside the LPR-B station.
There are 4 serial ports for connection. One port is for the configuration of the LPR-B station
(S4: parameterization port) another one is the port for the distance data (S2: binary data).
Two other serial ports (S1 and S3) are not used for commissioning the system.
Figure 44 Data interface RS232
Data interfaces
S1
ARM9 serial
S2
Binary Data
S3
A9 serial
S4
Configuration ASCII (Service
Port)
For analyzing the LPR-B station use first the parameterization port (S4). Connect the serial
cable with the parameterization port (S4) and the COM interface with your computer.
If you use a USB-RS232 converter make sure that all necessary drivers are
installed for this hardware.
8.4.1 RealTerm (for parameterization port)
Open now the program RealTerm.
4 data interfaces
S1
S2
S3
S4