Safety Instructions

Table Of Contents
SYMEO LPR
®
LPR-1D
Product Documentation
Trouble Shooting
Copyright © Symeo GmbH 2010
Page 77 of 87
If you press button 1 (configuration menu)
and button 6 (setup) then you can get more
detail about the system. Click maybe on freeze
to enable the scroll bar and scroll up to setup
menu. Note the point .
With the character x you return to the main
menu.
Note here the information the station has/ stations have:
Master Transponder/ Base Station: _____________________
Station ID: _____________________
Group ID: _____________________
FSK channel: _____________________
----------------------------------------------------------------------------------------------------------------- --------
Master Transponder/ Base Station: _____________________
Station ID: _____________________
Group ID: _____________________
FSK channel: _____________________
-------------------------------------------------------------------------------------------------------------------------
Master Transponder/ Base Station: _____________________
Station ID: _____________________
Group ID: _____________________
FSK channel: _____________________
If you compare later the settings with the other stations in the systems, following settings
must be made. You need exactly one master transponder. The other stations must be base
stations.
The group ID must be identical for all stations in the system.
The FSK channel must be identical for all stations in the system.
The base stations must have different station IDs.
8.5 Connection to the LPR-B station with TCP/IP interface
If you have a station with TCP/IP interface you only can connect your PC via the TCP/IP
interface to the LPR-B station. For the connection you need a Ethernet cable.
The IP-address is set to the fixed IP address 192.168.1.99 when delivering the system to the
customer.
To get access to the station you need to set your PC in the network as the LPR-B station.