Scroll down to the section:
Serial-to-Ethernet:
Here you enter the connection type
for the parameterization port
(ttyAM1) and the binary port
(ttyAM2).
Both ports should be not disabled.
Choose the right connection type
and enter the data port. The data
port is per default 3045 for the
parameterization port and 3046 for
the binary port.
If you have made changes click on
Upload changes
Reboot system
After the reboot try again to get access to the LPR-B station as described in chapter 8.5.4.
8.6 No Measurements
You can get data on two ports: Parameterization port (S4) which is useful for the setup of the
system and the Binary Port (S2) compare figure Figure 44). The binary port is necessary if
you want to use the distance data for a system behind the LPR-B system. You will then use
Binary protocol and have to check that the binary port provides proper measurements.
Check List:
1) You have access with the program RealTerm to all stations. (If pressing the button 1
the LPR-B configuration menu is shown.)
2) The antennas are connected to the right port of the LPR-B station.
Transponder
Station 1
Base Station
Station 2
Base Station
Station 3
measurement 1
Antenna an Port
Antenna an Port
x