User's Manual

Table Of Contents
Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Symeo 2D Protocol
Copyright © Symeo 2012
Page 114 of 132
Name
Length
Type
Description
USER-DATA-SET
8
unsigned int
User data
Entire length of data packet: 8 Byte
This data field can be activated in the configuration file via the following line:
[SendUserData] 1
10.2.4.11 SYSTEM-ERROR
This data field provides information about possible errors of the system. Up to five errors can
be displayed simultaneously in one data packet. An error code is sent as long as an error
exists.
Name
Length
Type
Description
ERROR-CODE-1
1
unsigned int
Error code of 1
st
error
ERROR-VALUE-1
2
unsigned int
Error value of 1
st
error
ERROR-CODE-2
1
unsigned int
Error code of 2
nd
error
ERROR-VALUE-2
2
unsigned int
Error value of 2
nd
error
ERROR-CODE-3
1
unsigned int
Error code of 3
rd
error
ERROR-VALUE-3
2
unsigned int
Error value of 3
rd
error
ERROR-CODE-4
1
unsigned int
Error code of 4
th
error
ERROR-VALUE-4
2
unsigned int
Error value of 4
th
error
ERROR-CODE-5
1
unsigned int
Error code of 5
th
error
ERROR-VALUE-5
2
unsigned int
Error value of 5
th
error
Entire length of data packet: 15 Byte
A detailed description of all errors is written in chapter 10.6. If more than 5 errors exist at the
same time, the special error code 0xff is sent as the ERROR-CODE-5.
This data field can be enabled by the following instruction in the configuration file:
[SendSystemError] 1
10.2.4.12 SATELLITE-STATE
This data field is used for satellite-based localization and holds information about the
positioning quality.