User's Manual
Table Of Contents
- 1 General
- 2 Introduction
- 3 System Description
- 4 Hardware
- 5 Installation
- 6 Coordinate System
- 7 Commissioning
- 7.1 Check list installation and surveying
- 7.2 Editing of configuration files for the DSP
- 7.3 Upload of configuration files for the DSP
- 7.3.1 Connection with LPR mobile unit (type: compact) via TCP/IP
- 7.3.2 Connection with LPR mobile unit (type: compact) via RS232
- 7.3.3 Upload DSP configuration file for LPR mobile unit (base station)
- 7.3.4 Upload DSP configuration file for master transponder unit
- 7.3.5 Upload DSP configuration file for transponder unit
- 7.4 Editing of configuration files for Fusion Engine
- 7.5 Upload configuration files for FusionEngine
- 8 Symeo MAP
- 9 Network Settings
- 10 Symeo 2D Protocol
- 11 Appendix A: Agency certifications
Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Hardware
Copyright © Symeo 2012
Page 26 of 132
4 Hardware
All corresponding installation, repair and servicing work must be carried
out by qualified and trained technicians.
4.1 System components – Overview
The system can exist of multiple cells and mobile units for the vehicles. Each cell exists of 4
to 6 LPR transponder stations (type integral). Depending on the chosen operating mode a
master is added to each cell. The 4 to 6 LPR-2DB Integral Stations/ Transponders as well as
the master LPR-2DB Integral Station/ maser transponder is mounted at a fixed place, e.g. a
wall or light poles. On the mobile units LPR stations (type: compact, BSB000313,
BSB000319, BSB000603, BSB000604, BSB000605, BSB000606) are installed.
Additional hardware for the mobile units are connector boxes, connector cables and
antennas.
For the determination of the position of the LPR-2DB Integral Station at the light poles or at
the wall the system range of max. 300 meters and the position of the antennas on the
vehicles are important.
4.2 LPR-2DB Station (mobile station)
4.2.1 Overview compact station
Following hardware exists for an LPR station on the mobile unit:
BSB000313 (single receiver, TCP/IP interface, 2 antenna ports)
BSB000319 (single receiver, RS232 interface, 2 antenna ports)
BSB000603 (double receiver, TCP/IP interface, 4 antenna ports)
BSB000604 (double receiver, RS232 interface, 4 antenna ports)
BSB000605 (double receiver, TCP/IP interface, 2 antenna ports)
BSB000606 (double receiver, RS232 interface, 2 antenna ports)
4.2.2 Technical data compact station
Technical Data
Power draw
RS232 port, 4 W
TCP/IP port, 6 W
Voltage range
10-36VDC
Dimensions (LxWxH)
260 x 160 x 91 mm
Type of protection
IP 65 with appropriate cable connectors
Connections
Power-Supply and Communication: Plugged connection
Antenna: Screwed cable gland