User's Manual
Table Of Contents
- 1 General
- 2 Introduction
- 3 System Description
- 4 Hardware
- 5 Installation
- 6 Coordinate System
- 7 Commissioning
- 7.1 Check list installation and surveying
- 7.2 Editing of configuration files for the DSP
- 7.3 Upload of configuration files for the DSP
- 7.3.1 Connection with LPR mobile unit (type: compact) via TCP/IP
- 7.3.2 Connection with LPR mobile unit (type: compact) via RS232
- 7.3.3 Upload DSP configuration file for LPR mobile unit (base station)
- 7.3.4 Upload DSP configuration file for master transponder unit
- 7.3.5 Upload DSP configuration file for transponder unit
- 7.4 Editing of configuration files for Fusion Engine
- 7.5 Upload configuration files for FusionEngine
- 8 Symeo MAP
- 9 Network Settings
- 10 Symeo 2D Protocol
- 11 Appendix A: Agency certifications
Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Commissioning
Copyright © Symeo 2012
Page 58 of 132
Enter the coordinates from the surveyor for each transponder (T0 – T5) and for the master
transponder (T30) into the file for the master transponder. The values are x- , y-, z-direction
and the orientation of all transponders in x- and y-direction (see chapter 6.1).
Station-
ID
x-
coordinate
y-
coordinate
z-
coordinate
dir_x
(x-direction of
transponder)
dir_y
(y-direction of
transponder)
beam
width
Station-ID (0,1, 2, 3, 4, 5, 30) and beam width are entered by Symeo and are not allowed to
be changed. All coordinates must be provided in mm.
7.2.3 File stationXXY_config.txt
These files is preconfigured by delivery and needs no changes.
7.3 Upload of configuration files for the DSP
Each LPR unit (base station, transponder, master) has its own DSP. Each DSP of each LPR
station has its own configuration file.
The configuration files are:
Mobile unit (Base station)
Basestation_config.txt
Transponder
StationXX0.txt … stationXX5.txt (XX: Cell-ID)
Master (optionally)
StationXXM.txt (XX: Cell-ID, M: Master)
The access to the DSP of the mobile units is done via TCP/IP or serial interface. For the
fixed mounted units (transponder and master) the access to the DSP happens via the radio
communication from the mobile station.