User's Manual
Table Of Contents
- 1 General
- 2 Introduction
- 3 System Description
- 4 Hardware
- 5 Installation
- 6 Coordinate System
- 7 Commissioning
- 7.1 Check list installation and surveying
- 7.2 Editing of configuration files for the DSP
- 7.3 Upload of configuration files for the DSP
- 7.3.1 Connection with LPR mobile unit (type: compact) via TCP/IP
- 7.3.2 Connection with LPR mobile unit (type: compact) via RS232
- 7.3.3 Upload DSP configuration file for LPR mobile unit (base station)
- 7.3.4 Upload DSP configuration file for master transponder unit
- 7.3.5 Upload DSP configuration file for transponder unit
- 7.4 Editing of configuration files for Fusion Engine
- 7.5 Upload configuration files for FusionEngine
- 8 Symeo MAP
- 9 Network Settings
- 10 Symeo 2D Protocol
- 11 Appendix A: Agency certifications
Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Commissioning
Copyright © Symeo 2012
Page 59 of 132
DSP
Transponder
DSP
Master Mobile unit/ base station
ARM9
DSP
RS232
User
RS232 Service
TCP/IP
User & Service
RS232
User & Service
access via radio
channel (FSK channel)
access via
TCP/IP or
serial interface
access via radio
channel (FSK channel)
Figure 39 – LPR units including DSP: Access to the DSP via TCP/IP, RS232 or frequency
channel
7.3.1 Connection with LPR mobile unit (type: compact) via TCP/IP
If you have an LPR station (mobile unit) with TCP/IP interface read this
chapter. If you have an LPR station (mobile unit) with RS232 interface
read the next chapter (7.3.2).
Connect your PC and the mobile unit with a LAN cable
Keep in mind the necessary settings for the network (e.g. same network for PC and LPR
station). Compare chapter 9.1. The SCIA port (ttyAM0) must be opened for configuration.
The port is per default 3045 but is changeable via the web-interface of the station
(9.3.3.1).
Figure 40 – ports of LPR station
To check a successful a network connection, ping the IP-address of the station “ping
192.168.1.99”. The IP-address is per default 192.168.1.99 but is changeable via the web
interface of the station (9.3).
Open the terminal program “RealTerm”