User's Manual
Table Of Contents
- 1 General
- 2 Introduction
- 3 System Description
- 4 Hardware
- 5 Installation
- 6 Coordinate System
- 7 Commissioning
- 7.1 Check list installation and surveying
- 7.2 Editing of configuration files for the DSP
- 7.3 Upload of configuration files for the DSP
- 7.3.1 Connection with LPR mobile unit (type: compact) via TCP/IP
- 7.3.2 Connection with LPR mobile unit (type: compact) via RS232
- 7.3.3 Upload DSP configuration file for LPR mobile unit (base station)
- 7.3.4 Upload DSP configuration file for master transponder unit
- 7.3.5 Upload DSP configuration file for transponder unit
- 7.4 Editing of configuration files for Fusion Engine
- 7.5 Upload configuration files for FusionEngine
- 8 Symeo MAP
- 9 Network Settings
- 10 Symeo 2D Protocol
- 11 Appendix A: Agency certifications
Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Network Settings
Copyright © Symeo 2012
Page 85 of 132
9 Network Settings
Having a LPR station with TCP/IP interface the network settings for this station are described
in this chapter.
Therefore it is necessary to open a TCP/IP connection between your computer and the LPR
station.
9.1 TCP/IP connection between PC and LPR-2DB station
With delivery the LPR-2DB stations have the fixed IP-Address
192.168.1.99.
You can change the IP-Address of the LPR-2DB Station via the web interface of the LPR-
Station (see chapter 9.3).
To get a connection between your PC and the mobile station it is maybe
neccessary to change the network parameters of your computer. Both
units must be located in the same network. That means in this example
that the first three numeric pads of both IP-addresses must be the
same.
Disconnect your PC from the network. Connect the LPR-2DB station and the computer with a
network cable. Open your network settings of your computer.
Enter the following fixed IP-Address i.e.
192.168.1.1. The subnet mask should be set
to 255.255.255.0.
Click in both windows OK.
If you firewall settings are too restrictive, you may not get access to the
LPR-1D station. In this case temporarely deactivate the firewall under
the tab „Advanced“ in the dialog window “Network settings”.
The LPR-2DB Station should be available via your PC now. You can check the connection
with a „ping” to the LPR station: