User's Manual
Table Of Contents
- 1 General
- 2 Introduction
- 3 System Description
- 4 Hardware
- 5 Installation
- 6 Coordinate System
- 7 Commissioning
- 7.1 Check list installation and surveying
- 7.2 Editing of configuration files for the DSP
- 7.3 Upload of configuration files for the DSP
- 7.3.1 Connection with LPR mobile unit (type: compact) via TCP/IP
- 7.3.2 Connection with LPR mobile unit (type: compact) via RS232
- 7.3.3 Upload DSP configuration file for LPR mobile unit (base station)
- 7.3.4 Upload DSP configuration file for master transponder unit
- 7.3.5 Upload DSP configuration file for transponder unit
- 7.4 Editing of configuration files for Fusion Engine
- 7.5 Upload configuration files for FusionEngine
- 8 Symeo MAP
- 9 Network Settings
- 10 Symeo 2D Protocol
- 11 Appendix A: Agency certifications
Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Network Settings
Copyright © Symeo 2012
Page 90 of 132
disabled).
The NTP server is a server on the network from which the system can
request the current time.
9.3.3 Serial-to-Ethernet
ttyAM1
Port number of the TCP/IP port via which the data from serial port
(ttyAM1) is sent and received. ttyAM1 is the port for the parameterization
interface (Service Port).
(default: 3045)
ttyAM2
Port number of the TCP/IP port via which the data from serial port
ttyAM2) is sent and received. ttyAM2 is the port for the data interface
(Binary Port). If the software FusionEngine is operating on the ARM9
Board of the mobile unit, this port must be disabled! If the software
FusionEngine is operating an external PC, this port ttyAM2 must be
enabled.
(default: 3046)
Per default these two ports are not enabled. Choose the Connection
Type between the LPR station and your PC or PLC for each port.
Depending on the connection you select different masks are editable.
9.3.3.1 ttyAM1/ Parameterization port
Network Settings
IP (Server)
If applying Connection Type „TCP – Connecting to Data Port using
Reserve Port“ you enter here the IP-address of the server, to which the
connection should be established.
Data Port
Port-Number of TCP/IP Port. Data of serial interface (ttyAM1) is sent and
received. ttyAM1 is the parameterization port. Default value is 3045.
Reverse Port
If applying Connection Type „TCP – Connecting to Data Port using
Reverse Port“ you enter here the port, which the server should use for the
reverse channel.
Serial Settings Area
Speed
Baud rate of serial interface (ttyAM1). The baud rate of the
parameterization port is set to 115200 baud per default.
Options
Settings of serial interface ttyAM1 for the data protocol. These settings
are not necessary to change and are set per default to raw –echo –ixon
(Raw data, no echo, no control character).