Installation Guide
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800)796-6667 ■
Fax: (800)961-9621
©2014 Symmons Industries, Inc. ■ Printed in U.S.A. ■ www.symmons.com ■ gethelp@symmons.com ■ 092614
nished wall
Floor
hot / cold
supply
showerhead
supply
7-1/2" sq
(191 mm)
Temptrol
control valve
valve mounting
plate,
*
Notes (1)(2)
COLD
supply
showerhead
supply
HOT
supply
Finished wall to rear of valve
3-1/2"
±
1/2" (89 mm
±
13 mm
Finished wall to pipe centerline
2-3/8"
±
1/2" (60 mm
±
13 mm)
*See note (2)
Wall cutout hole size
3-1/2" (89 mm) min
4" (101 mm) min
*
Notes:
(1) Walls for using T-177 mounting plate (MP)
■ Wall is 1/16" (2 mm) min • 1/2" (13 mm) max
■ Fiber or acrylic walls (MP required)
■ Plaster or other type walls 1/2" or less (MP optional)
■ Protective shield usage (optional)
(2) Dry wall, plaster or other type walls 1/2" or greater
■ Protective shield is required; snaps on end of valve spindle....
(3)
Do not install positive shut-off devices or devices that do not
allow the valve to ow at least 1.5 gpm on control valve outlets.
(4) Dimensions subject to change without notice
Protective Shield
p/n T-176
32"
(813 mm)
3-3/8" ± ½"
(85 mm ±13 mm)
3-1/8"
(80 mm)
Dimensions Duro Shower Valve System, 3600