Installation guide

3
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
gethelp@symmons.com
ZV-3043 REV 0 01/15/2014
53-458-TRM, 53-460-TRM
Museo
Diverter Trim Series
Operation & Maintenance Manual
Installation Diverter Control
Note: For rough-in installation,
please see valve body installation
guide.
1) Install plastic mounting plate (I)
to diverter valve (53-458-TRM
diverter valve = 4-458E-BODY,
53-460-TRM diverter valve =
4-460E-BODY).
Secure with two screws (H).
2) Attach diverter escutcheon (G) to
plastic mounting plate (I).
Note: Tabs should snap into place.
3) Install dome cover (F) to valve by
turning clockwise.
4) Insert handle insert (D) into
handle (C). Attach handle (C) to
valve.
5) Secure handle (C) to valve using
star washer (E) and screw (B).
Attach plug button (A) to handle.
Note: Handle should be facing the
6 o'clock position.
1) Diverter handle facing straight
down is for diverter function 1.
2) 53-458-TRM: Turn diverter
handle counterclockwise one full
revolution for diverter function 2.
53-460-TRM: Turn diverter
handle counterclockwise 1/4 turn
for diverter function 2.
3) 53-460-TRM: Turn diverter
handle counterclockwise 3/4 turn
for diverter function 3.
1
2
H
I
G
I
53-458-TRM 53-460-TRM
1
2
F
2
1
C
D
C
1
3
2
E
B
C
A
Care and Cleaning
1) Clean nished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse
with water.