Installation Sheet
QUITE DIRTY, REMOVE VALVE SPINDLE
OR STOP SPINDLES (IF SO EQUIPPED)
TO INSURE PROPER FLUSHING. See
service instructions.
7. Push escutcheon (T-169) against
wall and secure to valve with two
escutcheon screws (DF-9B). Mount
temperature control handle (RC-14X)
on valve spindle spline as shown in
figure 9. Install shower arm, flange and
shower head. See Figures 2 and 3.
8. Do not install positive shut-off devices
on the outlet of this valve or devices
that do not allow the valve to flow at
least 1 GPM at 50 psi inlet pressure.
EXCEPTION: If a self-closing or slow-
closing valve is installed on the outlet,
the supplies of the valve must be
equipped with checks to eliminate hot
to cold by-pass in the event the valve’s
handle is not turned to off after use.
Contact your factory representative or
Symmons directly for information on
available checks.
FIBERGLASS WALL INSTALLATION
When installing Temptrol
®
in fiberglass
or panel walls and it is desired to
sandwich wall between valve body
and escutcheon, cut hole in wall
as shown in Figure 5 and mount
valve with T-177 wall mounting
flange from rear. Note: It is always
recommended to secure valve
piping to rough construction and
not depend on fiberglass wall
for valve mounting security. On
panel walls over 1” thick, install in
conventional manner.
6 1/2"
164m m
4 5/8"
116m m
7 3/8"
187m m
4"
102mm min.
less stops
5 1/2"
140mm min.
with stops
5/8"
16mm
1/2"
13mm
1/2"
13mm
1/2"
13mm
2"
51mm
approx.
24"
610m m
approx.
48"
1219m m
shower
dischar ge
nished wall
hot and
cold inlets
adjustment
oor line
FIGURE 3
Model: C-96-1 Shower System
?sghbj?v‘kk
gnkd?rhyd
P
PU
FF?Qfifi
?•–
R
S
FF?PXfifi
S?PNQA?GPPSfifiH?l¢»
SA?GPOPfifiH?l“fl
ef?v¢››?l–‚fl•“fl¤?
e›¢fl¤ƒ
sLPVV?v¢››?l–‚fl•“fl¤?e›¢fl¤ƒ
e–·?????????QPfifi?•–?PA?QTfifi?
•'“⁄‹?”¢››?–·¥ƒ·?†¢·•?fl–M?sLPXR
PR
PU
FF
FIGURE 5
Install plug her e for
shower only installation
Install plug her e for
tub only installation
Copper sweat plug
1/2"-14 NPT plug
(pipe sealer r equired)
or
FIGURE 3A
4. Tighten packing nut (T-17) for positive
frictional resistance to handle turn
throughout adjustment cycle and at
shut-off position. Check valve cap,
packing nut, all valve, pipe and fitting
connections for leaks.
5. SET LIMIT STOP SCREW AS DIRECTED
AFTER “IMPORTANT” IN BOLD TYPE ON
PAGE ONE. Attach dome cover (T-19)
onto packing nut (T-17) and secure
with lock nut (T-20).
6. ALLOW VALVE TO RUN IN WARM
POSITION FOR A FEW MINUTES TO
TOTALLY FLUSH SYSTEM. IF SYSTEM IS