Installation Sheet

INSTALLATION:
Caution: Be sure to turn o hot and cold water supplies
before installing or servicing faucet.
1.
Push valve bodies through holes in sink from underneath. Make
sure mounting nuts (RT-103N) are on underside of sink. Valve
marked Hot is on the le and Cold is on the right. Put gasket
(LN-129) over valve body.  read escutcheon (LN-128) onto valve
bodies.  e top of the valve spindle should measure 1-7/8” from
mounting surface (See rough in drawing).
2.  read collar (LN-112 or LN-111) on to valve body until it reaches the
escutcheon (LN-128). Tighten mounting nuts from underneath sink.
3. Standard or LWG handle installation: Place bushing (LN-115) on
valve spindle. Turn valves to o position (CR style: turn clockwise;
LWG, LCF, LPO, LAM, and standard style: turn hot clockwise,
turn cold counterclockwise). Place handle (LN-131) on bushing.
read screw (LN-146 or LN-121) into valve and push plug button
(T-33R and T-33B) into top of handle. CR, LCF, LPO and LAM
handle installation: Place lever part of handle on valve spindle and
thread screw (LN-121 or LN-134) into valve.
4. Swivel spout option: Place spout assembly (LN-200) in centerbody
(LN-197).  read nut (LN-199) onto centerbody (LN-197).
Rigid spout option:  read screw (LN-205) into the bottom of the
spout assembly (LN-200). Place spout assembly (LN-200) in center
body (LN-197).  read nut (LN-199) onto center body (LN-197).
5. Drop assembled center body and spout through center hole of deck.
7/8" (22mm) min
1-3/8" (35mm) max
hole size
1-1/16" (27mm) min
1-7/16" (37mm) max
hole size
Escutcheon
S-254-CR handle
S-254
standard
handle shown
S-254-LAM
S-254-LPO
S-254-LCF
S-254-LTM
Dimensions Symmetrix, S-254, S-254-CR, S-254-LAM, S-254-LPO, S-254-LCF, S-254-LTM
Note: Dimensions subject to
change without notice.
Secure assembly to sink using nut (SPF-26) and washer (LN-138).
6.  read adapter (LN-189) onto the end of the center body (LN-197).
read ex hoses (LN-157) into center body using pipe dope or te on
tape on the pipe threads.  read ex hoses (LN-157) into center body.
read other end to valve bodies. Note:  e adapter can be backed o
a full turn to allow better positioning on the  ex hoses.
7. Connect hot supply to le tube and cold supply to right tube using
appropriate connectors.
8. It is very important to thoroughly  ush the supply lines to prevent
foreign matter, i.e. copper chips, sand, stones, etc. from damaging
the sealing surfaces of cartridge. Remove aerator and open hot and
cold to full open then open both supplies. Let water run through
hot and cold long enough to  ush supply lines thoroughly. Shut o
faucet and replace aerator. Check for leaks.
Cartridge Replacement (KN-113 or KN-114):
1. Remove plug button (T-33, T-33R or T-33B), loosen Philip head
screw (LN-121) and remove handle, (LN-131 or LN 152).
2. Remove collars (LN-112) by turning counter clockwise, do not use
wrench as this may damage the surface  nish.
3. Place wrench on cartridge hex nut (KN-113, KN-114). Turn
wrench counter clockwise until cartridge is removed.
4. Install new cartridge. Turn cartridge with wrench until cartridge
does not turn easily then turn 1/4 to 1/2 turn further. Reassemble
handle in reverse fashion.