Installation Guide

6
ZV-3253 REV C
SERVICE & MAINTENANCE
1. Remove Cartridge
1. Remove lever (A) from handle hub (C) with
soft jaw pliers as to avoid damaging finish
on lever handle. Use 2.5mm hex key to
remove set screw (B) from handle hub.
2. Remove handle hub (C) from faucet.
3. Remove decorative collar (D).
4. Remove compression nut (E).
5. Remove cartridge (F) from faucet body.
Inspect cartridge for debris and replace
cartridge if necessary.
2. Replace Cartridge
1. Orient cartridge so pegs align with holes in
faucet body (see illustration to the left for
reference.)
2. To install cartridge, reverse steps 1-5 in the
Remove Cartridge section above.
2
1
A
B
C
3
D
4
E
F
5
(2x)
HOLES
FOR PEGS
(2x) PEGS
CARTRIDGE
BOTTOM VIEW
IMPORTANT: Soft jaw pliers must be
used on lever handle to avoid damaging
decorative finish.