Installation Sheet

Sensor recognition range is factory
preset at 1/2 - 4 inches
Place hand under faucet, water will ow
automatically for 10 seconds and shut o.
Auto shut-off time is factory preset
at 1/2 to 1 second
Remove hands, water will stop automatically
within 1/2 to 1 second.
Security OFF after 10 seconds
Faucet will automatically shut o aer
continuous water ow for 10 seconds.
Weak or dead battery
LED will ash to signal battery is getting
weak and should be replaced soon.
Operation
Cleaning surface finish
Block sensor with plastic cleaning cover to prevent faucet from
turning on while cleaning.
Clean nish area by using mild soap and water or non-
abrasive cleaner and then rinse immediately. A non-
abrasive wax may be used to preserve nish area.
Precautions
Ensure sensor is not damaged through impact or scratches.
Ensure sensor is not blocked or disturbed by any object
with its detection range.
Ensure that no strong light source is aimed directly at
sensor or through a mirror.
Risk of Freezing
When installing the faucet in a location where the temperature
may fall below freezing, the entire system must be drained of
water to prevent damage in freezing weather.
Turn o water supply.
Disconnect all exible hoses.
Drain all parts and hoses of water.
Faucet care
Sensor eye is blinking
Indicates battery is weak and needs to be replaced.
No water flow
Check water supply to the faucet.
Clean around photo cell sensor area.
Check for loose battery connections.
Replace the solenoid valve.
Replace the sensor.
Water flow is weak
Water supply stops are not fully open.
Clean aerator and check strainer on end of supply line(s).
Excessive clogging may require installing of separate
ecient lter into supply line.
Water flow from spout fails to turn off
Sensing range may be too low. Clean around photo cell
sensor area.
Clean solenoid valve membrane or replace solenoid valve.
Water temperature can’t be adjusted
Clean the check strainer on end of supply line(s).
Clean or replace the mixer.
Troubleshooting
Using Temperature adjustment handle
Remove temperature adjustment handle.
Set maximum water temperature limit by turning handle
limit stop clockwise (CW).
Increase maximum water temperature by turning handle
limit stop counter clockwise (CCW).
Re-install temperature adjustment handle.
Adjusting preset water temperature (cong #2)
Remove temperature adjustment handle plug.
Adjust the maximum water temperature limit by inserting
handle into faucet and turning counter clockwise (CCW).
Increase temperature by turning handle clockwise (CW).
Remove handle and re-install plug.
Limiting water temperature
Page 3Page 3