Installation Guide

Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2015 Symmons Industries, Inc. www.symmons.com gethelp@symmons.com ZV-3117 REV B 112515
Troubleshooting Chart
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
7) Attach supply lines to 1/2” IPS inlet
connections on faucet body (H).
Using a wrench, nish with one half
turn. DO NOT overtighten.
1
1
2
I
Maintenance
1) Remove plug button (C) and
set screw (B). Turning counter-
clockwise, disassemble handle
(A), collar (D) and nut (F) from
cartridge (G).
B
C
A
D
F
G
2) Remove cartridge (G) from faucet
body (H). Inspect for debris.
Replace cartridge if necessary.
G
H
0.0
0.2
0.4
0.6
0.8
1.0
3) Correctly align cartridge (G) and
insert into faucet body (H). Install
handle assembly following step 1
in reverse.
1
1
1
1
4
2
H
8) Attach supply lines to shut-off
valves and hand tighten. Using a
wrench, nish with one-half turn.
DO NOT overtighten.
1
1
2
9) Remove aerator (I) and ush lines
free of debris. Check for leaks.
B
C
A
D
F
G
1
H
Installation
Note: Counterclock-
wise to lower tem-
perature, clockwise
to increase tempera-
ture.