Cartridge Temperature Limit Stop Instructions
Problem Cause Solution
Flow is irregular.
Accumulation of sediment in spray
wand.
Remove and clean spray wand (J).
Replace spray wand if necessary.
Same as above. Accumulation of sediment in cartridge.
Remove and clean cartridge (K). See
Maintenance section (page 4). Replace
cartridge if necessary.
Handle is sticking to cartridge. Same as above. Same as above.
Handle is loose. Set screw has loosened. Tighten set screw (I).
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Troubleshooting Chart
1) Remove limit stop (K2) from
cartridge (K1). Turn limit stop
counterclockwise to allow full handle
turn to the hot position. Turn limit
stop clockwise to limit handle turn to
the hot position.
K1
K2
K1
K2
FOR NEW INSTALLATIONS FOR REPLACING KN-4 CARTRIDGE
2) Remove limit stop (K2) from
cartridge (K1). Turn limit stop
counterclockwise to allow full handle
turn to the hot position. Turn limit
stop clockwise to limit handle turn to
the hot position.